{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T14:07:01Z","timestamp":1772806021794,"version":"3.50.1"},"reference-count":64,"publisher":"Association for Computing Machinery (ACM)","issue":"3","license":[{"start":{"date-parts":[[2022,9,6]],"date-time":"2022-09-06T00:00:00Z","timestamp":1662422400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."],"published-print":{"date-parts":[[2022,9,6]]},"abstract":"<jats:p>Refractive error is the most common eye disorder and is the key cause behind correctable visual impairment, responsible for nearly 80% of the visual impairment in the US. Refractive error can be diagnosed using multiple methods, including subjective refraction, retinoscopy, and autorefractors. Although subjective refraction is the gold standard, it requires cooperation from the patient and hence is not suitable for infants, young children, and developmentally delayed adults. Retinoscopy is an objective refraction method that does not require any input from the patient. However, retinoscopy requires a lens kit and a trained examiner, which limits its use for mass screening. In this work, we automate retinoscopy by attaching a smartphone to a retinoscope and recording retinoscopic videos with the patient wearing a custom pair of paper frames. We develop a video processing pipeline that takes retinoscopic videos as input and estimates the net refractive error based on our proposed extension of the retinoscopy mathematical model. Our system alleviates the need for a lens kit and can be performed by an untrained examiner. In a clinical trial with 185 eyes, we achieved a sensitivity of 91.0% and specificity of 74.0% on refractive error diagnosis. Moreover, the mean absolute error of our approach was 0.75\u00b10.67D on net refractive error estimation compared to subjective refraction measurements. Our results indicate that our approach has the potential to be used as a retinoscopy-based refractive error screening tool in real-world medical settings.<\/jats:p>","DOI":"10.1145\/3550283","type":"journal-article","created":{"date-parts":[[2022,9,7]],"date-time":"2022-09-07T14:54:27Z","timestamp":1662562467000},"page":"1-26","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Towards Automating Retinoscopy for Refractive Error Diagnosis"],"prefix":"10.1145","volume":"6","author":[{"given":"Aditya","family":"Aggarwal","sequence":"first","affiliation":[{"name":"Microsoft Research, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddhartha","family":"Gairola","sequence":"additional","affiliation":[{"name":"Microsoft Research, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Uddeshya","family":"Upadhyay","sequence":"additional","affiliation":[{"name":"Microsoft Research, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akshay P.","family":"Vasishta","sequence":"additional","affiliation":[{"name":"Sankara Eye Hospital, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diwakar","family":"Rao","sequence":"additional","affiliation":[{"name":"Sankara Eye Hospital, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aditya","family":"Goyal","sequence":"additional","affiliation":[{"name":"Sankara Eye Hospital, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaushik","family":"Murali","sequence":"additional","affiliation":[{"name":"Sankara Eye Hospital, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nipun","family":"Kwatra","sequence":"additional","affiliation":[{"name":"Microsoft Research, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohit","family":"Jain","sequence":"additional","affiliation":[{"name":"Microsoft Research, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2022,9,7]]},"reference":[{"key":"e_1_2_1_1_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0219501"},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001843"},{"key":"e_1_2_1_3_1","volume-title":"Evidence-based clinical practice guideline: Comprehensive pediatric eye and vision examination. Optometric Clinical Practice","author":"American Optometric Association","year":"2020","unstructured":"American Optometric Association. 2020. Evidence-based clinical practice guideline: Comprehensive pediatric eye and vision examination. Optometric Clinical Practice (2020), 2--67."},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0192055"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12112"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1145\/3476064"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","unstructured":"Paul Boeder and H. E. Kolder. 1984. Neutralization at Infinity in Streak Retinoscopy. Archives of Ophthalmology 102 9 (09 1984) 1396--1399. https:\/\/doi.org\/10.1001\/archopht.1984.01040031138042 arXiv:https:\/\/jamanetwork.com\/journals\/jamaophthalmology\/articlepdf\/635237\/archopht_102_9_042.pdf","DOI":"10.1001\/archopht.1984.01040031138042"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.2139\/ssrn.3582742"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1969.00990010851018"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.5201\/ipol.2011.bcm_nlm"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.1986.4767851"},{"key":"e_1_2_1_12_1","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.jaapos.2014.03.012","article-title":"Creating a digital retinoscope by combining a mobile smartphone camera and a retinoscope","volume":"18","author":"Chan Weng Onn","year":"2014","unstructured":"Weng Onn Chan, Matthew Crabb, David Sia, and Deepa Ajay Taranath. 2014. Creating a digital retinoscope by combining a mobile smartphone camera and a retinoscope. Journal of AAPOS: the official publication of the American Association for Pediatric Ophthalmology and Strabismus 18 4 (2014), 387--8.","journal-title":"Journal of AAPOS: the official publication of the American Association for Pediatric Ophthalmology and Strabismus"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1364\/OE.11.001628"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.01.084"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000726"},{"key":"e_1_2_1_16_1","unstructured":"J.M. Corboy. 2003. The Retinoscopy Book: An Introductory Manual for Eye Care Professionals. Slack. https:\/\/books.google.co.in\/books?id=6I6JeDWonhQC"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","unstructured":"I. Cosme-Cisneros G. Escamilla-Ruiz D. Flores-Montoya G. Hern\u00e1ndez-G\u00f3mez and A. G\u00f3mez-Vieyra. 2017. Instrument for Recording Purkinje Images. 101--109. https:\/\/doi.org\/10.1007\/978-3-319-28513-9_14","DOI":"10.1007\/978-3-319-28513-9_14"},{"key":"e_1_2_1_18_1","first-page":"5","article-title":"Blindness in the Indian state of Andhra Pradesh","volume":"42","author":"Dandona L","year":"2001","unstructured":"L Dandona, R Dandona, M Srinivas, P Giridhar, K Vilas, M N Prasad, R K John, C A McCarty, and G N Rao. 2001. Blindness in the Indian state of Andhra Pradesh. Invest Ophthalmol Vis Sci 42, 5 (April 2001), 908--916.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2012.09.012"},{"key":"e_1_2_1_20_1","volume-title":"Chen Change Loy, and Xiaoou Tang","author":"Dong Chao","year":"2016","unstructured":"Chao Dong, Chen Change Loy, and Xiaoou Tang. 2016. Accelerating the Super-Resolution Convolutional Neural Network. In Computer Vision - ECCV 2016, Bastian Leibe, Jiri Matas, Nicu Sebe, and Max Welling (Eds.). Springer International Publishing, Cham, 391--407."},{"key":"e_1_2_1_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/opx.0000000000000732"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12310"},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.18-25957"},{"key":"e_1_2_1_24_1","unstructured":"LVPEI Center for Innovation. 2018. FoFo (Folding Foropter) project. Retrieved January 1 2022 from https:\/\/www.fofo-project.com\/"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1145\/3394171.3413748"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1145\/3494982"},{"key":"e_1_2_1_27_1","volume-title":"Keratoconus Classifier for Smartphone-based Corneal Topographer. In 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE.","author":"Gairola Siddhartha","year":"2022","unstructured":"Siddhartha Gairola, Pallavi Joshi, Anand Balasubramaniam, Kaushik Murali, Nipun Kwatra, and Mohit Jain. 2022. Keratoconus Classifier for Smartphone-based Corneal Topographer. In 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE."},{"key":"e_1_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.5505\/ptd.2015.59455"},{"key":"e_1_2_1_29_1","doi-asserted-by":"crossref","unstructured":"R. I. Hartley and A. Zisserman. 2004. Multiple View Geometry in Computer Vision (second ed.). Cambridge University Press ISBN: 0521540518.","DOI":"10.1017\/CBO9780511811685"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0255643"},{"key":"e_1_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.1987.4767964"},{"key":"e_1_2_1_32_1","doi-asserted-by":"publisher","DOI":"10.1097\/opx.0000000000001308"},{"key":"e_1_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.6061\/clinics\/2016(02)03"},{"key":"e_1_2_1_34_1","volume-title":"which is the best starting point for a noncycloplegic refraction? Optometry and vision science: official publication of the American Academy of Optometry 82, 1 (January","author":"Jorge Jorge","year":"2005","unstructured":"Jorge Jorge, Ant\u00f3nio Queir\u00f3s, Jos\u00e9 B Almeida, and Manuel A Parafita. 2005. Retinoscopy\/autorefraction: which is the best starting point for a noncycloplegic refraction? Optometry and vision science: official publication of the American Academy of Optometry 82, 1 (January 2005), 64--68. http:\/\/europepmc.org\/abstract\/MED\/15630406"},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1214\/aoms\/1177729694"},{"key":"e_1_2_1_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.1989.tb00487.x"},{"key":"e_1_2_1_37_1","unstructured":"Olivia L Lee. 2015. Retinoscopy 101. Retrieved February 1 2022 from https:\/\/www.aao.org\/young-ophthalmologists\/yo-info\/article\/retinoscopy-101"},{"key":"e_1_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2010.134"},{"key":"e_1_2_1_39_1","doi-asserted-by":"publisher","DOI":"10.1109\/CVPR.2017.515"},{"key":"e_1_2_1_40_1","doi-asserted-by":"publisher","DOI":"10.1145\/3090085"},{"key":"e_1_2_1_41_1","doi-asserted-by":"publisher","unstructured":"Sara J McCullough Lesley Doyle and Kathryn J Saunders. 2017. Intra- and inter- examiner repeatability of cycloplegic retinoscopy among young children. Ophthalmic & physiological optics: the journal of the British College of Ophthalmic Opticians (Optometrists) 37 1 (January 2017) 16--23. https:\/\/doi.org\/10.1111\/opo.12341","DOI":"10.1111\/opo.12341"},{"key":"e_1_2_1_42_1","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_2912_20"},{"key":"e_1_2_1_43_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000796"},{"key":"e_1_2_1_44_1","volume-title":"World report on vision","author":"World Health Organization","unstructured":"World Health Organization. 2019. World report on vision. World Health Organization. 160 p. pages."},{"key":"e_1_2_1_45_1","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.1979.4310076"},{"key":"e_1_2_1_46_1","doi-asserted-by":"publisher","DOI":"10.1090\/conm\/443\/08555"},{"key":"e_1_2_1_47_1","doi-asserted-by":"publisher","DOI":"10.1145\/1778765.1778814"},{"key":"e_1_2_1_48_1","doi-asserted-by":"publisher","DOI":"10.1145\/3448106"},{"key":"e_1_2_1_49_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2011-300539"},{"key":"e_1_2_1_50_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-016-0247-8"},{"key":"e_1_2_1_51_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2007.133454"},{"key":"e_1_2_1_52_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.14.002547"},{"key":"e_1_2_1_53_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1970.00990040051013"},{"key":"e_1_2_1_54_1","doi-asserted-by":"publisher","DOI":"10.4103\/2320-3897.116861"},{"key":"e_1_2_1_55_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep07976"},{"key":"e_1_2_1_56_1","first-page":"2","article-title":"Blindness and visual impairment in an American urban population. The Baltimore Eye Survey","volume":"108","author":"Tielsch J M","year":"1990","unstructured":"J M Tielsch, A Sommer, K Witt, J Katz, and R M Royall. 1990. Blindness and visual impairment in an American urban population. The Baltimore Eye Survey. Arch Ophthalmol 108, 2 (Feb. 1990), 286--290.","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_1_57_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1080-7"},{"key":"e_1_2_1_58_1","doi-asserted-by":"publisher","DOI":"10.1145\/3173574.3173999"},{"key":"e_1_2_1_59_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.8.002038"},{"key":"e_1_2_1_60_1","volume-title":"Amblyopia in children (aged 7 years or less). BMJ clinical evidence 2016 (01","author":"West Stephanie","year":"2016","unstructured":"Stephanie West and Cathy Williams. 2016. Amblyopia in children (aged 7 years or less). BMJ clinical evidence 2016 (01 2016)."},{"key":"e_1_2_1_61_1","doi-asserted-by":"publisher","DOI":"10.1145\/3428690.3429175"},{"key":"e_1_2_1_62_1","volume-title":"Portable wavefront aberrometer. 9066683 (06","author":"Zhou Yaopeng","year":"2015","unstructured":"Yaopeng Zhou. 2015. Portable wavefront aberrometer. 9066683 (06 2015). https:\/\/www.freepatentsonline.com\/9066683.html"},{"key":"e_1_2_1_63_1","volume-title":"Nowalk","author":"Zitelli Basil J.","year":"2012","unstructured":"Basil J. Zitelli, Sara C. McIntire, and Andrew J. Nowalk. 2012. Zitelli and Davis' atlas of pediatric physical diagnosis. Saunders\/Elsevier."},{"key":"e_1_2_1_64_1","doi-asserted-by":"crossref","unstructured":"Karel J. Zuiderveld. 1994. Contrast Limited Adaptive Histogram Equalization. In Graphics Gems.","DOI":"10.1016\/B978-0-12-336156-1.50061-6"}],"container-title":["Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3550283","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3550283","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,14]],"date-time":"2025-07-14T04:42:13Z","timestamp":1752468133000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3550283"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,6]]},"references-count":64,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,9,6]]}},"alternative-id":["10.1145\/3550283"],"URL":"https:\/\/doi.org\/10.1145\/3550283","relation":{},"ISSN":["2474-9567"],"issn-type":[{"value":"2474-9567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,6]]},"assertion":[{"value":"2022-09-07","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}