{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T15:56:22Z","timestamp":1780674982184,"version":"3.54.1"},"reference-count":39,"publisher":"Association for Computing Machinery (ACM)","issue":"3","license":[{"start":{"date-parts":[[2022,9,6]],"date-time":"2022-09-06T00:00:00Z","timestamp":1662422400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."],"published-print":{"date-parts":[[2022,9,6]]},"abstract":"<jats:p>In this paper, we propose VitaNet, a radio frequency based contactless approach that accurately estimates the PPG signal using radar for stationary participants. The main insight behind VitaNet is that the changes in the blood volume that manifest in the PPG waveform are correlated to the physical movements of the heart, which the radar can capture. To estimate the PPG waveform, VitaNet uses a self-attention architecture to identify the most informative reflections in an unsupervised manner, and then uses an encoder decoder network to transform the radar phase profile to the PPG sequence. We have trained and extensively evaluated VitaNet on a large dataset obtained from 25 participants over 179 full nights. Our evaluations show that VitaNet accurately estimates the PPG waveform and its derivatives with high accuracy, significantly improves the heart rate and heart rate variability estimates from the prior works, and also accurately estimates several useful PPG features. We have released the codes of VitaNet as well as the trained models and the dataset used in this paper.<\/jats:p>","DOI":"10.1145\/3550330","type":"journal-article","created":{"date-parts":[[2022,9,7]],"date-time":"2022-09-07T14:54:27Z","timestamp":1662562467000},"page":"1-30","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":12,"title":["Contactless Monitoring of PPG Using Radar"],"prefix":"10.1145","volume":"6","author":[{"given":"Usman Mahmood","family":"Khan","sequence":"first","affiliation":[{"name":"North Carolina State University, Raleigh, North Carolina, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Rigazio","sequence":"additional","affiliation":[{"name":"Koko Home, Palo Alto, California, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Shahzad","sequence":"additional","affiliation":[{"name":"North Carolina State University, Raleigh, North Carolina, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2022,9,7]]},"reference":[{"key":"e_1_2_1_1_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.32.2.365"},{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/57.5.524"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2007.897805"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1536\/ihj.39.775"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.2174\/157340312801215782"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.earlhumdev.2013.09.016"},{"key":"e_1_2_1_7_1","volume-title":"Camera-based photoplethysmography in an intraoperative setting. BioMedical Engineering OnLine, 17(33)","author":"Trump A.","year":"2018","unstructured":"A. Trump et al. Camera-based photoplethysmography in an intraoperative setting. BioMedical Engineering OnLine, 17(33), 2018."},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.6.001565"},{"key":"e_1_2_1_9_1","first-page":"837","volume-title":"In Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems","author":"Adib F.","year":"2016","unstructured":"F. Adib et al. Smart homes that monitor breathing and heart rate. In In Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems, page 837-846, 2016."},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.3390\/s20082351"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/JETCAS.2018.2818181"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1145\/3372224.3419982"},{"key":"e_1_2_1_13_1","volume-title":"Radar-based heart sound detection. Sci Rep, 8(11551)","author":"Will C.","year":"2018","unstructured":"C. Will et al. Radar-based heart sound detection. Sci Rep, 8(11551), 2018."},{"key":"e_1_2_1_14_1","volume-title":"Contactless electrocardiogram monitoring with millimeter wave radar","author":"Chen J.","year":"2021","unstructured":"J. Chen et al. Contactless electrocardiogram monitoring with millimeter wave radar. 2021."},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISCIT52804.2021.9590627"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/JERM.2017.2766567"},{"key":"e_1_2_1_17_1","volume-title":"Radar-based high-accuracy cardiac activity sensing. 70:1--13","author":"Xia W.","year":"2021","unstructured":"W. Xia, Y. Li, and S.Dong. Radar-based high-accuracy cardiac activity sensing. 70:1--13, 2021."},{"key":"e_1_2_1_18_1","first-page":"71","volume-title":"10th USENIX Symposium on Networked Systems Design and Implementation (NSDI 13)","author":"Xiong J.","year":"2013","unstructured":"J. Xiong and K. Jamieson. Arraytrack: A fine-grained indoor location system. In 10th USENIX Symposium on Networked Systems Design and Implementation (NSDI 13), pages 71-84, 2013."},{"key":"e_1_2_1_19_1","unstructured":"https:\/\/gitfront.io\/r\/user-1279687\/e8560251380cfa75ca3ce8b77cbad826614e7654\/vitanet\/."},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1152\/ajplegacy.1938.124.2.328"},{"issue":"4","key":"e_1_2_1_21_1","first-page":"371","article-title":"Determination of age-related increases in large artery stiffness by digital pulse contour analysis clinical science","volume":"103","author":"Millasseau S.","year":"2002","unstructured":"S. Millasseau et al. Determination of age-related increases in large artery stiffness by digital pulse contour analysis clinical science. Hypertension, 103(4):371--377, 2002.","journal-title":"Hypertension"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.2486\/indhealth.37.3"},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISPACS.2006.364747"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.10.004353"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40064-015-1583-5"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-74048-3_4"},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/0471656372"},{"key":"e_1_2_1_28_1","first-page":"7064","volume-title":"Proceedings of the 36th International Conference on Machine Learning","author":"Ye J. C.","year":"2019","unstructured":"J. C. Ye and W. K. Sung. Understanding geometry of encoder-decoder cnns. In Proceedings of the 36th International Conference on Machine Learning, pages 7064-7073, 2019."},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.5555\/3298023.3298188"},{"key":"e_1_2_1_30_1","unstructured":"https:\/\/www.ti.com\/tool\/IWR6843AOPEVM."},{"key":"e_1_2_1_31_1","doi-asserted-by":"crossref","unstructured":"Fadel Adib et al. Capturing the human figure through a wall. ACM Transactions on Graphics 34(6) 2015.","DOI":"10.1145\/2816795.2818072"},{"key":"e_1_2_1_32_1","unstructured":"https:\/\/choosemuse.com\/muse-s\/."},{"key":"e_1_2_1_33_1","unstructured":"https:\/\/coral.ai\/products\/dev-board\/."},{"key":"e_1_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1017\/S1759078711000122"},{"issue":"1","key":"e_1_2_1_35_1","first-page":"23","article-title":"A novel non-contact heart rate monitor using impulse-radio ultra-wideband (ir-uwb) radar technology","volume":"22","author":"Lee Y.","year":"2008","unstructured":"Y. Lee et al. A novel non-contact heart rate monitor using impulse-radio ultra-wideband (ir-uwb) radar technology. Journal Clinical Monitoring and Computing, 22(1):23--29, 2008.","journal-title":"Journal Clinical Monitoring and Computing"},{"key":"e_1_2_1_36_1","doi-asserted-by":"publisher","DOI":"10.15420\/aer.2018.27.2"},{"key":"e_1_2_1_37_1","volume-title":"Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? Scientific Reports, 8(13053)","author":"Lu S.","year":"2018","unstructured":"S. Lu et al. Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? Scientific Reports, 8(13053), 2018."},{"key":"e_1_2_1_38_1","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2009.5333091"},{"key":"e_1_2_1_39_1","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.2698"}],"container-title":["Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3550330","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3550330","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,14]],"date-time":"2025-07-14T04:39:52Z","timestamp":1752467992000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3550330"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,6]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,9,6]]}},"alternative-id":["10.1145\/3550330"],"URL":"https:\/\/doi.org\/10.1145\/3550330","relation":{},"ISSN":["2474-9567"],"issn-type":[{"value":"2474-9567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,6]]},"assertion":[{"value":"2022-09-07","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}