{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T22:15:41Z","timestamp":1795126541356,"version":"4.10.3"},"publisher-location":"New York, NY, USA","reference-count":65,"publisher":"ACM","license":[{"start":{"date-parts":[[2022,11,7]],"date-time":"2022-11-07T00:00:00Z","timestamp":1667779200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,11,7]]},"DOI":"10.1145\/3560826.3563380","type":"proceedings-article","created":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T00:06:25Z","timestamp":1667520385000},"page":"1-13","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":24,"title":["Security Analysis of Vendor Implementations of the OPC UA Protocol for Industrial Control Systems"],"prefix":"10.1145","author":[{"given":"Alessandro","family":"Erba","sequence":"first","affiliation":[{"name":"CISPA Helmholtz Center for Information Security &amp; Saarland University, Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"M\u00fcller","sequence":"additional","affiliation":[{"name":"CISPA Helmholtz Center for Information Security &amp; Saarland University, Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nils Ole","family":"Tippenhauer","sequence":"additional","affiliation":[{"name":"CISPA Helmholtz Center for Information Security, Saarbr\u00fccken, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2022,11,7]]},"reference":[{"key":"e_1_3_2_2_1_1","volume-title":"accessed","author":"ABB.","year":"2020","unstructured":"ABB. accessed November 3, 2020 . AC500 USER MANAGEMENT WITH V3CONFIGURATION AND HANDLING , version 3ADR010315. https:\/\/library.e.abb.com\/public\/2745203d43f64bf2af9add792d5b4e46\/AC500%20-%20Application%20Note%203ADR010315.pdf. ABB. accessed November 3, 2020. AC500 USER MANAGEMENT WITH V3CONFIGURATION AND HANDLING, version 3ADR010315. https:\/\/library.e.abb.com\/public\/2745203d43f64bf2af9add792d5b4e46\/AC500%20-%20Application%20Note%203ADR010315.pdf."},{"key":"e_1_3_2_2_2_1","doi-asserted-by":"publisher","DOI":"10.1109\/SP.2017.52"},{"key":"e_1_3_2_2_3_1","volume-title":"accessed","author":"G.","year":"2020","unstructured":"ASNe G. accessed December 10, 2020 . OPC UA implementation, version 3.8.1. https:\/\/github.com\/ASNeG\/OpcUaStack. ASNeG. accessed December 10, 2020. OPC UA implementation, version 3.8.1. https:\/\/github.com\/ASNeG\/OpcUaStack."},{"key":"e_1_3_2_2_4_1","volume-title":"accessed","year":"2021","unstructured":"Bachmann. accessed 14 January , 2021 . OPC UA Client and Server , version 09\/2020. https:\/\/www.bachmann.info\/fileadmin\/media\/Produkte\/Vernetzung\/Produktblaetter\/Software_OPC-UA-client_server_en.pdf. Bachmann. accessed 14 January, 2021. OPC UA Client and Server, version 09\/2020. https:\/\/www.bachmann.info\/fileadmin\/media\/Produkte\/Vernetzung\/Produktblaetter\/Software_OPC-UA-client_server_en.pdf."},{"key":"e_1_3_2_2_5_1","volume-title":"accessed","year":"2021","unstructured":"Beckhoff. accessed 14 January , 2021 . TC3 OPC UA , version 2.9. https:\/\/download.beckhoff.com\/download\/document\/automation\/twincat3\/TF6100_TC3_OPC-UA_EN.pdf. Beckhoff. accessed 14 January, 2021. TC3 OPC UA, version 2.9. https:\/\/download.beckhoff.com\/download\/document\/automation\/twincat3\/TF6100_TC3_OPC-UA_EN.pdf."},{"key":"e_1_3_2_2_6_1","volume-title":"accessed","author":"Beijer Electronics","year":"2020","unstructured":"Beijer Electronics Automation AB. accessed November 3, 2020 . OPC UA Server - iX Developer 2.4 KI 00312A. https:\/\/www.beijerelectronics.tw\/en\/Support\/file-archive-tree-page?docId=58657. Beijer Electronics Automation AB. accessed November 3, 2020. OPC UA Server - iX Developer 2.4 KI00312A. https:\/\/www.beijerelectronics.tw\/en\/Support\/file-archive-tree-page?docId=58657."},{"key":"e_1_3_2_2_7_1","volume-title":"accessed","author":"Bosch Rexroth","year":"2020","unstructured":"Bosch Rexroth AG. accessed November 3, 2020 . OPC UA Server Application Manual , R911403778 Edition 01. https:\/\/www.boschrexroth.com\/various\/utilities\/mediadirectory\/download\/index.jsp?object_nr=R911403779. Bosch Rexroth AG. accessed November 3, 2020. OPC UA Server Application Manual, R911403778 Edition 01. https:\/\/www.boschrexroth.com\/various\/utilities\/mediadirectory\/download\/index.jsp?object_nr=R911403779."},{"key":"e_1_3_2_2_8_1","volume-title":"accessed","author":"R Industrial Automation","year":"2020","unstructured":"B& R Industrial Automation GmbH. accessed November 3, 2020 . ADI OPC UA server User's manual, version 1.27. https:\/\/www.br-automation.com\/es-mx\/descargar\/industrial-pcs-and-panels\/automation-pc-3100\/kabylake-system-unit\/windows-10-iot-enterprise-2016-ltsb\/adi-opc-ua-server-users-manual\/. B&R Industrial Automation GmbH. accessed November 3, 2020. ADI OPC UA server User's manual, version 1.27. https:\/\/www.br-automation.com\/es-mx\/descargar\/industrial-pcs-and-panels\/automation-pc-3100\/kabylake-system-unit\/windows-10-iot-enterprise-2016-ltsb\/adi-opc-ua-server-users-manual\/."},{"key":"e_1_3_2_2_10_1","doi-asserted-by":"publisher","DOI":"10.1145\/3243734.3243746"},{"key":"e_1_3_2_2_11_1","volume-title":"accessed","year":"2020","unstructured":"Codesys. accessed December 10, 2020 . OPC UA Server , version 3.5.14.0. https:\/\/help.codesys.com\/api-content\/2\/codesys\/3.5.14.0\/en\/_cds_runtime_opc_ua_server\/. Codesys. accessed December 10, 2020. OPC UA Server, version 3.5.14.0. https:\/\/help.codesys.com\/api-content\/2\/codesys\/3.5.14.0\/en\/_cds_runtime_opc_ua_server\/."},{"key":"e_1_3_2_2_12_1","volume-title":"accessed","author":"CODESYS.","year":"2021","unstructured":"CODESYS. accessed January 14, 2021 . CODESYS OPC UA PubSub SL. https:\/\/store.codesys.com\/op-ua-pubsub-sl.html?___store=en&___from_store=default. CODESYS. accessed January 14, 2021. CODESYS OPC UA PubSub SL. https:\/\/store.codesys.com\/op-ua-pubsub-sl.html?___store=en&___from_store=default."},{"key":"e_1_3_2_2_13_1","volume-title":"accessed","author":"Converter Systems","year":"2020","unstructured":"Converter Systems LLC. accessed December 10, 2020 . OPC UA implementaion. https:\/\/github.com\/convertersystems\/opc-ua-client. Converter Systems LLC. accessed December 10, 2020. OPC UA implementaion. https:\/\/github.com\/convertersystems\/opc-ua-client."},{"key":"e_1_3_2_2_14_1","doi-asserted-by":"publisher","DOI":"10.1145\/3419394.3423666"},{"key":"e_1_3_2_2_15_1","volume-title":"25th $$USENIX$$ Security Symposium ($$USENIX$$ Security 16). 193--208.","author":"Dechand Sergej","unstructured":"Sergej Dechand , Dominik Sch\u00fcrmann , Karoline Busse , Yasemin Acar , Sascha Fahl , and Matthew Smith . 2016. An empirical study of textual key-fingerprint representations . In 25th $$USENIX$$ Security Symposium ($$USENIX$$ Security 16). 193--208. Sergej Dechand, Dominik Sch\u00fcrmann, Karoline Busse, Yasemin Acar, Sascha Fahl, and Matthew Smith. 2016. An empirical study of textual key-fingerprint representations. In 25th $$USENIX$$ Security Symposium ($$USENIX$$ Security 16). 193--208."},{"key":"e_1_3_2_2_16_1","volume-title":"accessed","year":"2020","unstructured":"Eaton. accessed December 10, 2020 . XC300 Modular control, version MN 050005EN. https:\/\/es-assets.eaton.com\/DOCUMENTATION\/AWB_MANUALS\/MN050005_EN.pdf. Eaton. accessed December 10, 2020. XC300 Modular control, version MN050005EN. https:\/\/es-assets.eaton.com\/DOCUMENTATION\/AWB_MANUALS\/MN050005_EN.pdf."},{"key":"e_1_3_2_2_17_1","volume-title":"accessed","author":"Milo Eclipse","year":"2020","unstructured":"Eclipse Milo . accessed December 10, 2020 . OPC UA implementation, version 0.5.1. https:\/\/github.com\/eclipse\/milo. Eclipse Milo. accessed December 10, 2020. OPC UA implementation, version 0.5.1. https:\/\/github.com\/eclipse\/milo."},{"key":"e_1_3_2_2_18_1","volume-title":"accessed","author":"Electric Schneider","year":"2020","unstructured":"Schneider Electric . accessed November 3, 2020 . M580 BMENUA0100 OPC UA Embedded Module Installation and Configuration Guide , version 10\/2019. https:\/\/download.schneider-electric.com\/files?p_enDocType=Userguide&p_File_Name=PHA83350.00.pdf&p_Doc_Ref=PHA83350. Schneider Electric. accessed November 3, 2020. M580 BMENUA0100 OPC UA Embedded Module Installation and Configuration Guide, version 10\/2019. https:\/\/download.schneider-electric.com\/files?p_enDocType=Userguide&p_File_Name=PHA83350.00.pdf&p_Doc_Ref=PHA83350."},{"key":"e_1_3_2_2_19_1","doi-asserted-by":"publisher","DOI":"10.1145\/2590296.2590341"},{"key":"e_1_3_2_2_20_1","unstructured":"OPC Foundation. 2018. OPC Unified Architecture Specification v1.04. https:\/\/opcfoundation.org\/developer-tools\/specifications-unified-architecture.  OPC Foundation. 2018. OPC Unified Architecture Specification v1.04. https:\/\/opcfoundation.org\/developer-tools\/specifications-unified-architecture."},{"key":"e_1_3_2_2_21_1","volume-title":"accessed","author":"Free OPC","year":"2020","unstructured":"Free OPC UA. accessed December 10, 2020 . OPC UA implementation, version 0.98.12. https:\/\/github.com\/FreeOpcUa\/python-opcua. Free OPC UA. accessed December 10, 2020. OPC UA implementation, version 0.98.12. https:\/\/github.com\/FreeOpcUa\/python-opcua."},{"key":"e_1_3_2_2_22_1","volume-title":"accessed","year":"2020","unstructured":"FreeOpcUa. accessed December 10, 2020 . OPC UA implementation. http:\/\/freeopcua.github.io\/. FreeOpcUa. accessed December 10, 2020. OPC UA implementation. http:\/\/freeopcua.github.io\/."},{"key":"e_1_3_2_2_23_1","volume-title":"German Federal Ministry for Economic Affairs and Energy (BMWi), Plattform Industrie 4.0, Italian Ministero dello Sviluppo Economico and Piano Nazionale Impresa 4.0. accessed","author":"Economy French Ministry","year":"2021","unstructured":"French Ministry of Economy and Finance , Alliance Industrie du Futur , German Federal Ministry for Economic Affairs and Energy (BMWi), Plattform Industrie 4.0, Italian Ministero dello Sviluppo Economico and Piano Nazionale Impresa 4.0. accessed July 25, 2021 . The Structure of the Administration Shell : TRILATERAL PERSPECTIVES from France, Italy and Germany . https:\/\/www.de.digital\/DIGITAL\/Redaktion\/EN\/Publikation\/the-structure-of-the-administration-shell.pdf?__blob=publicationFile&v=3. French Ministry of Economy and Finance, Alliance Industrie du Futur, German Federal Ministry for Economic Affairs and Energy (BMWi), Plattform Industrie 4.0, Italian Ministero dello Sviluppo Economico and Piano Nazionale Impresa 4.0. accessed July 25, 2021. The Structure of the Administration Shell: TRILATERAL PERSPECTIVES from France, Italy and Germany. https:\/\/www.de.digital\/DIGITAL\/Redaktion\/EN\/Publikation\/the-structure-of-the-administration-shell.pdf?__blob=publicationFile&v=3."},{"key":"e_1_3_2_2_24_1","volume-title":"accessed","author":"Electric General","year":"2020","unstructured":"General Electric . accessed November 3, 2020 . Certificate Management and the OPC UA Server , version 6.1. https:\/\/www.ge.com\/digital\/documentation\/ifix\/version61\/Subsystems\/OPCUASVR\/content\/opcua_about_the_trust_list.htm. General Electric. accessed November 3, 2020. Certificate Management and the OPC UA Server, version 6.1. https:\/\/www.ge.com\/digital\/documentation\/ifix\/version61\/Subsystems\/OPCUASVR\/content\/opcua_about_the_trust_list.htm."},{"key":"e_1_3_2_2_25_1","volume-title":"accessed","author":"Go","year":"2020","unstructured":"Go opcua. accessed December 10, 2020 . OPC UA implementation, version 0.1.13. https:\/\/github.com\/gopcua\/opcua. Go opcua. accessed December 10, 2020. OPC UA implementation, version 0.1.13. https:\/\/github.com\/gopcua\/opcua."},{"key":"e_1_3_2_2_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/MSP.2016.111"},{"key":"e_1_3_2_2_27_1","volume-title":"accessed","year":"2020","unstructured":"Hitachi. accessed November 3, 2020 . HX Series Application Manual, verison NJI- 638(X). https:\/\/www.hitachi-da.com\/files\/pdfs\/produkte\/SPS\/HX\/HX-CPU_Software(Tentative).pdf. Hitachi. accessed November 3, 2020. HX Series Application Manual, verison NJI-638(X). https:\/\/www.hitachi-da.com\/files\/pdfs\/produkte\/SPS\/HX\/HX-CPU_Software(Tentative).pdf."},{"key":"e_1_3_2_2_28_1","volume-title":"accessed","author":"International Honeywell","year":"2020","unstructured":"Honeywell International . accessed November 3, 2020 . Control Edge Builder Protocol Configuration Reference Guide, version RTDOC-X 288-en-161A. https:\/\/www.honeywellprocess.com\/library\/support\/Public\/Documents\/ControlEdge-Builder-Protocol-Configuration-Reference-Guide-RTDOC-X288-en-161A.pdf. Honeywell International. accessed November 3, 2020. Control Edge Builder Protocol Configuration Reference Guide, version RTDOC-X288-en-161A. https:\/\/www.honeywellprocess.com\/library\/support\/Public\/Documents\/ControlEdge-Builder-Protocol-Configuration-Reference-Guide-RTDOC-X288-en-161A.pdf."},{"key":"e_1_3_2_2_29_1","volume-title":"accessed","author":"Messtechnik Hottinger Baldwin","year":"2020","unstructured":"Hottinger Baldwin Messtechnik Gmb H. accessed December 10, 2020 . OPC UA implementation. https:\/\/github.com\/HBM\/opcua. Hottinger Baldwin Messtechnik GmbH. accessed December 10, 2020. OPC UA implementation. https:\/\/github.com\/HBM\/opcua."},{"key":"e_1_3_2_2_30_1","volume-title":"accessed","year":"2021","unstructured":"Issue. accessed January 14, 2021 a. Client certificates are not validated #392. https:\/\/github.com\/FreeOpcUa\/python-opcua\/issues\/392. Issue. accessed January 14, 2021a. Client certificates are not validated #392. https:\/\/github.com\/FreeOpcUa\/python-opcua\/issues\/392."},{"key":"e_1_3_2_2_31_1","volume-title":"accessed","year":"2021","unstructured":"Issue. accessed January 14, 2021 b. Client certificates are not validated #44. https:\/\/github.com\/ASNeG\/OpcUaStack\/issues\/44. Issue. accessed January 14, 2021b. Client certificates are not validated #44. https:\/\/github.com\/ASNeG\/OpcUaStack\/issues\/44."},{"key":"e_1_3_2_2_32_1","volume-title":"accessed","year":"2021","unstructured":"Issue. accessed January 23, 2021 c. Regression with username\/password authentication #244. https:\/\/github.com\/eclipse\/milo\/issues\/244. Issue. accessed January 23, 2021c. Regression with username\/password authentication #244. https:\/\/github.com\/eclipse\/milo\/issues\/244."},{"key":"e_1_3_2_2_33_1","doi-asserted-by":"publisher","DOI":"10.1109\/ETFA.2018.8502603"},{"key":"e_1_3_2_2_34_1","doi-asserted-by":"publisher","DOI":"10.1109\/SP.2019.00060"},{"key":"e_1_3_2_2_35_1","volume-title":"Security Symposium ($$USENIX$$ Security 17)","author":"Krombholz Katharina","year":"2017","unstructured":"Katharina Krombholz , Wilfried Mayer , Martin Schmiedecker , and Edgar Weippl . 2017 . \u201c I Have No Idea What I'm Doing\u201d--On the Usability of Deploying HTTPS. In 26th $$USENIX$$ Security Symposium ($$USENIX$$ Security 17) . 1339--1356. Katharina Krombholz, Wilfried Mayer, Martin Schmiedecker, and Edgar Weippl. 2017. \u201cI Have No Idea What I'm Doing\u201d--On the Usability of Deploying HTTPS. In 26th $$USENIX$$ Security Symposium ($$USENIX$$ Security 17). 1339--1356."},{"key":"e_1_3_2_2_36_1","volume-title":"accessed","year":"2020","unstructured":"Lenze. accessed November 3, 2020 . Lenze OPC UA Communication , version v1.1. https:\/\/download.lenze.com\/AKB\/English\/201400321\/Commissioning_Lenze_OPC_UA_V1_1.pdf. Lenze. accessed November 3, 2020. Lenze OPC UA Communication, version v1.1. https:\/\/download.lenze.com\/AKB\/English\/201400321\/Commissioning_Lenze_OPC_UA_V1_1.pdf."},{"key":"e_1_3_2_2_37_1","volume-title":"accessed","author":"UA.","year":"2020","unstructured":"Lib UA. accessed October , 2020 . OPC UA implmentation. https:\/\/github.com\/nauful\/LibUA. LibUA. accessed October, 2020. OPC UA implmentation. https:\/\/github.com\/nauful\/LibUA."},{"key":"e_1_3_2_2_38_1","doi-asserted-by":"publisher","DOI":"10.1109\/WoWMoM.2016.7523562"},{"key":"e_1_3_2_2_39_1","volume-title":"Portable Trust Anchor for OPC UA Using Auto-Configuration. In 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA)","volume":"1","author":"Meier David","year":"2020","unstructured":"David Meier , Florian Patzer , Matthias Drexler , and J\u00fcrgen Beyerer . 2020 . Portable Trust Anchor for OPC UA Using Auto-Configuration. In 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) , Vol. 1 . IEEE, 270--277. David Meier, Florian Patzer, Matthias Drexler, and J\u00fcrgen Beyerer. 2020. Portable Trust Anchor for OPC UA Using Auto-Configuration. In 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA), Vol. 1. IEEE, 270--277."},{"key":"e_1_3_2_2_40_1","volume-title":"accessed","author":"Electric Mitsubishi","year":"2020","unstructured":"Mitsubishi Electric . accessed November 3, 2020 . MELSEC iQ-R OPC UA Server ModuleUser's Manual, version RD 81OPC96-SW1DND-ROPCUA-E. https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/plc\/sh081693eng\/sh081693engf.pdf. Mitsubishi Electric. accessed November 3, 2020. MELSEC iQ-R OPC UA Server ModuleUser's Manual, version RD81OPC96-SW1DND-ROPCUA-E. https:\/\/dl.mitsubishielectric.com\/dl\/fa\/document\/manual\/plc\/sh081693eng\/sh081693engf.pdf."},{"key":"e_1_3_2_2_41_1","volume-title":"Open-Source OPC UA Security and Scalability. In 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA)","volume":"1","author":"M\u00fchlbauer Nikolas","year":"2020","unstructured":"Nikolas M\u00fchlbauer , Erkin Kirdan , Marc-Oliver Pahl , and Georg Carle . 2020 . Open-Source OPC UA Security and Scalability. In 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) , Vol. 1 . IEEE, 262--269. Nikolas M\u00fchlbauer, Erkin Kirdan, Marc-Oliver Pahl, and Georg Carle. 2020. Open-Source OPC UA Security and Scalability. In 2020 25th IEEE International Conference on Emerging Technologies and Factory Automation (ETFA), Vol. 1. IEEE, 262--269."},{"key":"e_1_3_2_2_42_1","volume-title":"accessed","author":"National Instruments.","year":"2020","unstructured":"National Instruments. accessed November 3, 2020 . InsightCM 3.7 Manual . https:\/\/www.ni.com\/documentation\/en\/insightcm\/latest\/serverconf\/secure-opc-server\/. National Instruments. accessed November 3, 2020. InsightCM 3.7 Manual. https:\/\/www.ni.com\/documentation\/en\/insightcm\/latest\/serverconf\/secure-opc-server\/."},{"key":"e_1_3_2_2_43_1","doi-asserted-by":"publisher","DOI":"10.1145\/3360664.3360675"},{"key":"e_1_3_2_2_44_1","volume-title":"accessed","year":"2020","unstructured":"Node-opcua. accessed December 10, 2020 . OPC UA implementation, version 2.13.0. http:\/\/node-opcua.github.io\/. Node-opcua. accessed December 10, 2020. OPC UA implementation, version 2.13.0. http:\/\/node-opcua.github.io\/."},{"key":"e_1_3_2_2_45_1","volume-title":"accessed","year":"2020","unstructured":"Omron. accessed November 3, 2020 . NJ-series CPU Unit OPC UA User's Manual (W 588). https:\/\/assets.omron.eu\/downloads\/manual\/en\/v2\/w588_nj-series_cpu_unit_opc_ua_users_manual_en.pdf. Omron. accessed November 3, 2020. NJ-series CPU Unit OPC UA User's Manual (W588). https:\/\/assets.omron.eu\/downloads\/manual\/en\/v2\/w588_nj-series_cpu_unit_opc_ua_users_manual_en.pdf."},{"key":"e_1_3_2_2_46_1","unstructured":"OPC Foundation. 2017a. OPC Unified Architecture Specification Part 12\/section 7.7.7: GetRejectedList v1.04.  OPC Foundation. 2017a. OPC Unified Architecture Specification Part 12\/section 7.7.7: GetRejectedList v1.04."},{"key":"e_1_3_2_2_47_1","unstructured":"OPC Foundation. 2017b. OPC Unified Architecture Specification Part 4: Services v1.04.  OPC Foundation. 2017b. OPC Unified Architecture Specification Part 4: Services v1.04."},{"key":"e_1_3_2_2_48_1","unstructured":"OPC Foundation. 2017c. OPC Unified Architecture Specification Part 6: Mappings v1.04.  OPC Foundation. 2017c. OPC Unified Architecture Specification Part 6: Mappings v1.04."},{"key":"e_1_3_2_2_49_1","unstructured":"OPC Foundation. 2018. OPC Unified Architecture Specification Part 2: Security Model v1.04.  OPC Foundation. 2018. OPC Unified Architecture Specification Part 2: Security Model v1.04."},{"key":"e_1_3_2_2_50_1","volume-title":"accessed","author":"Foundation OPC","year":"2020","unstructured":"OPC Foundation . accessed December 10, 2020 . OPC UA implemntation, version 1.4.363.49. https:\/\/github.com\/OPCFoundation\/UA-.NETStandard. OPC Foundation. accessed December 10, 2020. OPC UA implemntation, version 1.4.363.49. https:\/\/github.com\/OPCFoundation\/UA-.NETStandard."},{"key":"e_1_3_2_2_51_1","volume-title":"accessed","year":"2020","unstructured":"opcua4j. accessed December 10, 2020 . OPC UA implementation. https:\/\/code.google.com\/p\/opcua4j\/. opcua4j. accessed December 10, 2020. OPC UA implementation. https:\/\/code.google.com\/p\/opcua4j\/."},{"key":"e_1_3_2_2_52_1","volume-title":"accessed","year":"2020","unstructured":"Open62541. accessed December 10, 2020 . OPC UA implementation, version 1.1.2. http:\/\/open62541.org\/. Open62541. accessed December 10, 2020. OPC UA implementation, version 1.1.2. http:\/\/open62541.org\/."},{"key":"e_1_3_2_2_53_1","volume-title":"accessed","author":"Interface OpenScada UA","year":"2020","unstructured":"OpenScada UA Interface . accessed December 10, 2020 . OPC UA implementation, version 1.7. http:\/\/oscada.org\/main\/documentation\/. OpenScada UA Interface. accessed December 10, 2020. OPC UA implementation, version 1.7. http:\/\/oscada.org\/main\/documentation\/."},{"key":"e_1_3_2_2_54_1","volume-title":"accessed","author":"Works Panasonic Electric","year":"2020","unstructured":"Panasonic Electric Works . accessed November 3, 2020 . HMWIN User Manual , verison v208. https:\/\/mediap.industry.panasonic.eu\/assets\/download-files\/import\/mn_hmwin_user_peweu_en.pdf. Panasonic Electric Works. accessed November 3, 2020. HMWIN User Manual, verison v208. https:\/\/mediap.industry.panasonic.eu\/assets\/download-files\/import\/mn_hmwin_user_peweu_en.pdf."},{"key":"e_1_3_2_2_55_1","doi-asserted-by":"publisher","DOI":"10.1109\/CCNC.2019.8651671"},{"key":"e_1_3_2_2_56_1","volume-title":"accessed","author":"Automation Rockwell","year":"2020","unstructured":"Rockwell Automation . accessed November 3, 2020 . FactoryTalk Linx Gateway Getting Results Guide, version FTLG-GR 001C-EN-E. https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/gr\/ftlg-gr001_-en-e.pdf. Rockwell Automation. accessed November 3, 2020. FactoryTalk Linx Gateway Getting Results Guide, version FTLG-GR001C-EN-E. https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/gr\/ftlg-gr001_-en-e.pdf."},{"key":"e_1_3_2_2_57_1","volume-title":"accessed","author":"Rust","year":"2020","unstructured":"Rust opc UA. accessed December 10, 2020 . OPC UA implementation, version 0.7. https:\/\/github.com\/locka99\/opcua. Rust opc UA. accessed December 10, 2020. OPC UA implementation, version 0.7. https:\/\/github.com\/locka99\/opcua."},{"key":"e_1_3_2_2_58_1","volume-title":"accessed","author":"OPC.","year":"2020","unstructured":"S2 OPC. accessed December 10, 2020 . OPC UA implementation, version 1.1.0. https:\/\/gitlab.com\/systerel\/S2OPC. S2OPC. accessed December 10, 2020. OPC UA implementation, version 1.1.0. https:\/\/gitlab.com\/systerel\/S2OPC."},{"key":"e_1_3_2_2_59_1","doi-asserted-by":"publisher","DOI":"10.1145\/2744769.2747942"},{"key":"e_1_3_2_2_60_1","volume-title":"accessed","author":"Siemens","year":"2020","unstructured":"Siemens AG. accessed December 10, 2020 . OPC UA. NET Client for the SIMATIC S7--1500 OPC UA Server, version 109737901 V1.3. https:\/\/cache.industry.siemens.com\/dl\/files\/901\/109737901\/att_955026\/v3\/109737901_OPC_UA_Client_S7--1500_DOKU_V13_en.pdf. Siemens AG. accessed December 10, 2020. OPC UA. NET Client for the SIMATIC S7--1500 OPC UA Server, version 109737901 V1.3. https:\/\/cache.industry.siemens.com\/dl\/files\/901\/109737901\/att_955026\/v3\/109737901_OPC_UA_Client_S7--1500_DOKU_V13_en.pdf."},{"key":"e_1_3_2_2_61_1","volume-title":"accessed","author":"Register The","year":"2022","unstructured":"The Register . accessed August 26, 2022 . Software developer cracks Hyundai car security with Google search. https:\/\/www.theregister.com\/2022\/08\/17\/software_developer_cracks_hyundai_encryption. The Register. accessed August 26, 2022. Software developer cracks Hyundai car security with Google search. https:\/\/www.theregister.com\/2022\/08\/17\/software_developer_cracks_hyundai_encryption."},{"key":"e_1_3_2_2_62_1","volume-title":"accessed","author":"Automation Unified","year":"2021","unstructured":"Unified Automation . accessed January 14, 2021 . Step-by-Step Connect Example , version 1.4.2. http:\/\/documentation.unified-automation.com\/uaexpert\/1.4.2\/html\/first_steps.html#connect_step-by-step. Unified Automation. accessed January 14, 2021. Step-by-Step Connect Example, version 1.4.2. http:\/\/documentation.unified-automation.com\/uaexpert\/1.4.2\/html\/first_steps.html#connect_step-by-step."},{"key":"e_1_3_2_2_63_1","first-page":"750","volume":"750","author":"Kontakttechnik WAGO","year":"2020","unstructured":"WAGO Kontakttechnik Gmb H. accessed November 3 , 2020 . WAGO-I\/O-SYSTEM 750 , 750 -- 758 xxx OPC UA Server, version 1.0.0. https:\/\/www.wago.com\/global\/d\/3597419. WAGO Kontakttechnik GmbH. accessed November 3, 2020. WAGO-I\/O-SYSTEM 750, 750--8xxx OPC UA Server, version 1.0.0. https:\/\/www.wago.com\/global\/d\/3597419.","journal-title":"WAGO-I\/O-SYSTEM"},{"key":"e_1_3_2_2_64_1","volume-title":"accessed","author":"Weidm\u00fcller Interface","year":"2020","unstructured":"Weidm\u00fcller Interface GmbH. accessed November 3, 2020 . u-create studio System manual, version 2696790000\/02\/04.2020. https:\/\/mdcop.weidmueller.com\/mediadelivery\/asset\/900_91150. Weidm\u00fcller Interface GmbH. accessed November 3, 2020. u-create studio System manual, version 2696790000\/02\/04.2020. https:\/\/mdcop.weidmueller.com\/mediadelivery\/asset\/900_91150."},{"key":"e_1_3_2_2_65_1","volume-title":"accessed","year":"2020","unstructured":"Yokogawa. accessed November 3, 2020 . OPC-UA Server (\/E3)User's Manual, version IM 04L51B01--20EN. http:\/\/web-material3.yokogawa.com\/IM04L51B01--20EN_010.pdf. Yokogawa. accessed November 3, 2020. OPC-UA Server (\/E3)User's Manual, version IM 04L51B01--20EN. http:\/\/web-material3.yokogawa.com\/IM04L51B01--20EN_010.pdf."},{"key":"e_1_3_2_2_66_1","volume-title":"accessed","author":"ZVEI -- German Electrical and Electronic Manufacturers' Association Automation Division.","year":"2021","unstructured":"ZVEI -- German Electrical and Electronic Manufacturers' Association Automation Division. accessed July 25, 2021 . Status Report Reference Architecture Model Industrie 4.0 (RAMI 4.0). https:\/\/www.zvei.org\/fileadmin\/user_upload\/Themen\/Industrie_4.0\/Das_Referenzarchitekturmodell_RAMI_4.0_und_die_Industrie_4.0-Komponente\/pdf\/5305_Publikation_GMA_Status_Report_ZVEI_Reference_Architecture_Model.pdf. io ZVEI -- German Electrical and Electronic Manufacturers' Association Automation Division. accessed July 25, 2021. Status Report Reference Architecture Model Industrie 4.0 (RAMI4.0). https:\/\/www.zvei.org\/fileadmin\/user_upload\/Themen\/Industrie_4.0\/Das_Referenzarchitekturmodell_RAMI_4.0_und_die_Industrie_4.0-Komponente\/pdf\/5305_Publikation_GMA_Status_Report_ZVEI_Reference_Architecture_Model.pdf. io"}],"event":{"name":"CCS '22: 2022 ACM SIGSAC Conference on Computer and Communications Security","location":"Los Angeles CA USA","acronym":"CCS '22","sponsor":["SIGSAC ACM Special Interest Group on Security, Audit, and Control"]},"container-title":["Proceedings of the 4th Workshop on CPS &amp; IoT Security and Privacy"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3560826.3563380","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3560826.3563380","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T15:00:34Z","timestamp":1750172434000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3560826.3563380"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,7]]},"references-count":65,"alternative-id":["10.1145\/3560826.3563380","10.1145\/3560826"],"URL":"https:\/\/doi.org\/10.1145\/3560826.3563380","relation":{},"subject":[],"published":{"date-parts":[[2022,11,7]]},"assertion":[{"value":"2022-11-07","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}