{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T07:39:17Z","timestamp":1771486757347,"version":"3.50.1"},"reference-count":34,"publisher":"Association for Computing Machinery (ACM)","issue":"2","license":[{"start":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T00:00:00Z","timestamp":1704758400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.acm.org\/publications\/policies\/copyright_policy#Background"}],"funder":[{"DOI":"10.13039\/501100001809","name":"NSFC","doi-asserted-by":"crossref","award":["12001042"],"award-info":[{"award-number":["12001042"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Beijing Municipal Natural Science Foundation","award":["1232019"],"award-info":[{"award-number":["1232019"]}]},{"DOI":"10.13039\/501100012236","name":"Beijing Institute of Technology research fund program for young scholars","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012236","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["ACM Trans. Sen. Netw."],"published-print":{"date-parts":[[2024,3,31]]},"abstract":"<jats:p>With the rapid development of the application of smart grids in different sectors, security management has become a major concern due to cyber attack risks. Correctly and accurately estimating the real status of a smart grid under false-data injection attacks (FDIAs) is currently an emerging concern. In response to that concern, this work proposes a distributed robust learning framework for the inference of the working status under data integrity attacks. The proposed paradigm incorporates the technology median-of-means that enables identifying the correct state against various kinds of FDIAs that can efficiently prevent misleading information during the decision-making process in control centers. Compared with existing defense methods, our method is entirely data driven without training data, highly accurate, and reliable for wide-spectrum FDIAs. More important, it is capable of defending large-scale power electronic networks due to its distributed learning framework. Extensive experimental results demonstrate that our approach can provide efficient protection for Photovoltaic (PV) systems from FDIAs.<\/jats:p>","DOI":"10.1145\/3588439","type":"journal-article","created":{"date-parts":[[2023,3,20]],"date-time":"2023-03-20T12:02:16Z","timestamp":1679313736000},"page":"1-12","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["A Robust Learning Framework for Smart Grids in Defense Against False-Data Injection Attacks"],"prefix":"10.1145","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-8931-3225","authenticated-orcid":false,"given":"Zhuoyi","family":"Miao","sequence":"first","affiliation":[{"name":"School of Mathematics and Statistics, Beijing Institute of Technology, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6068-8415","authenticated-orcid":false,"given":"Jun","family":"Yu","sequence":"additional","affiliation":[{"name":"School of Mathematics and Statistics, Beijing Institute of Technology, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"320","published-online":{"date-parts":[[2024,1,9]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2021.3114671"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2020.3017935"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1109\/MPEL.2017.2761422"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1109\/JIOT.2019.2897063"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2019.2943449"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/JIOT.2022.3143123"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2019.2948056"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/JESTIE.2021.3112919"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2021.3127353"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-cps.2018.5022"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-818701-2.00014-7"},{"key":"e_1_3_2_13_2","unstructured":"Brent Kesler. 2011. The Vulnerability of Nuclear Facilities to Cyber Attack. Strategic Insights Spring 10 1 (2011) 15\u201325."},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/MPER.1985.5528357"},{"key":"e_1_3_2_15_2","doi-asserted-by":"crossref","unstructured":"Jeu-Min Lin and Heng-Yau Pan. 2007. A static state estimation approach including bad data detection and identification in power systems. In 2007 IEEE Power Engineering Society General Meeting Tampa FL 1\u20137.","DOI":"10.1109\/PES.2007.385500"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2017.2703842"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIFS.2019.2902822"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1109\/JIOT.2021.3113900"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/DSN53405.2022.00045"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1109\/MWSCAS.1992.271039"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2004.11.002"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2014.2357182"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2503736"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2020.3026951"},{"key":"e_1_3_2_25_2","doi-asserted-by":"crossref","unstructured":"Yang Weng Rohit Negi Qixing Liu and Marija D. Ili\u0107. 2011. Robust state-estimation procedure using a least trimmed squares pre-processor. In ISGT\u201911 . Anaheim CA 1\u20136.","DOI":"10.1109\/ISGT.2011.5759135"},{"key":"e_1_3_2_26_2","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1002\/9781119480402.ch9","volume-title":"Advances in Electric Power and Energy: Static State Estimation","author":"Habiballah Ibrahim Omar","year":"2020","unstructured":"Ibrahim Omar Habiballah and Yuanhai Xia. 2020. Least trimmed absolute value state estimator. In Advances in Electric Power and Energy: Static State Estimation. 255\u2013294."},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-0000(73)80033-9"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1145\/1248377.1248401"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSIPN.2018.2876751"},{"key":"e_1_3_2_30_2","volume-title":"Modern Power System Analysis (in Chinese)","author":"Wang Xifan","year":"2003","unstructured":"Xifan Wang, Wanliang Fang, and Zhengchun Du. 2003. Modern Power System Analysis (in Chinese). Science Press."},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2014.2382714"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2010.2051168"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2004.11.002"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2015.2388545"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/0047-259X(84)90036-8"}],"container-title":["ACM Transactions on Sensor Networks"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3588439","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3588439","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T16:47:12Z","timestamp":1750178832000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3588439"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,9]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,3,31]]}},"alternative-id":["10.1145\/3588439"],"URL":"https:\/\/doi.org\/10.1145\/3588439","relation":{},"ISSN":["1550-4859","1550-4867"],"issn-type":[{"value":"1550-4859","type":"print"},{"value":"1550-4867","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,9]]},"assertion":[{"value":"2022-08-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-03-09","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-01-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}