{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T20:35:16Z","timestamp":1790454916615,"version":"4.1.0"},"reference-count":32,"publisher":"Association for Computing Machinery (ACM)","issue":"2","content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["ACM Trans. Des. Autom. Electron. Syst."],"published-print":{"date-parts":[[2026,3,31]]},"abstract":"<jats:p>\n                    Real-time execution of bioassays on microelectrode dot array (MEDA) biochips can revolutionize point-of-care diagnostics. Despite numerous design automation efforts for digital microfluidic biochips (DMFBs), there is no online synthesis framework for their advanced counterpart, MEDA biochips, which have various operational advantages. The DMFB-specific virtual topology\n                    <jats:italic toggle=\"yes\">[Grissom et\u00a0al., TCAD, 2014]<\/jats:italic>\n                    is inadequate for MEDA synthesis as it suffers from significant chip-area fragmentation issues. In this article, we propose a virtual topology that provides an abstraction of the physical geometry of MEDA biochips, thereby reducing the algorithmic runtime for MEDA synthesis by reducing the search space for optimization problems. On top of this, we propose an\n                    <jats:underline>A<\/jats:underline>\n                    rea-efficient\n                    <jats:underline>O<\/jats:underline>\n                    nline\n                    <jats:underline>P<\/jats:underline>\n                    lacer (\n                    <jats:italic toggle=\"yes\">AOP<\/jats:italic>\n                    ) to achieve placement results with minimum chip-area. However, due to the overuse of some microelectrodes, they may be degraded, which may result in unreliable outcomes of the bioassays.\n                    <jats:underline>P<\/jats:underline>\n                    lacement\n                    <jats:underline>R<\/jats:underline>\n                    eliability\n                    <jats:underline>E<\/jats:underline>\n                    nhancer (\n                    <jats:italic toggle=\"yes\">PRE<\/jats:italic>\n                    ) is proposed to improve the reliability of MEDA chips. Finally, a\n                    <jats:underline>F<\/jats:underline>\n                    ast\n                    <jats:underline>O<\/jats:underline>\n                    nline\n                    <jats:underline>S<\/jats:underline>\n                    ynthesis (\n                    <jats:italic toggle=\"yes\">FOS<\/jats:italic>\n                    ) is proposed for MEDA based on the virtual topology and these two methods, which always outperform the existing online synthesis in the average assay completion time and the number of routing sub-problems. Simulations confirm that\n                    <jats:italic toggle=\"yes\">AOP<\/jats:italic>\n                    significantly reduces both occupied area and algorithmic runtime compared with state-of-the-art\n                    <jats:italic toggle=\"yes\">WLSM<\/jats:italic>\n                    and\n                    <jats:italic toggle=\"yes\">RLPM<\/jats:italic>\n                    , albeit at the expense of reliability. By integrating\n                    <jats:italic toggle=\"yes\">PRE<\/jats:italic>\n                    ,\n                    <jats:italic toggle=\"yes\">AOP+PRE<\/jats:italic>\n                    achieves reliability similar to\n                    <jats:italic toggle=\"yes\">WLSM<\/jats:italic>\n                    and\n                    <jats:italic toggle=\"yes\">RLPM<\/jats:italic>\n                    , but requires additional chip area compared with\n                    <jats:italic toggle=\"yes\">AOP<\/jats:italic>\n                    while maintaining similar runtime efficiency. Hence,\n                    <jats:italic toggle=\"yes\">AOP+PRE<\/jats:italic>\n                    enables efficient and reliable online synthesis for MEDA biochips.\n                  <\/jats:p>","DOI":"10.1145\/3774890","type":"journal-article","created":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T11:45:17Z","timestamp":1762343117000},"page":"1-29","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Online Synthesis of MEDA Biochips with Area and Reliability-Aware Module Placement using Chamber-Less Virtual Topology"],"prefix":"10.1145","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-9290-3466","authenticated-orcid":false,"given":"Tamal","family":"Mandal","sequence":"first","affiliation":[{"name":"Department of Computer Science and Engineering, Indian Institute of Technology Roorkee","place":["Roorkee, India"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8437-8021","authenticated-orcid":false,"given":"Debraj","family":"Kundu","sequence":"additional","affiliation":[{"name":"Chair of EDA, Technical University of Munich","place":["Munich, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7873-3069","authenticated-orcid":false,"given":"Sudip","family":"Roy","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Engineering, IIT Roorkee","place":["Roorkee, India"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2025,12,17]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1039\/C1LC20851A"},{"key":"e_1_3_1_3_2","doi-asserted-by":"crossref","unstructured":"K. Chakrabarty and F. Su. 2007. Digital Microfluidic Biochips: Synthesis Testing and Reconfiguration Techniques. CRC Press.","DOI":"10.1201\/9781420008302"},{"key":"e_1_3_1_4_2","first-page":"4","article-title":"2008. High-level synthesis of digital microfluidic biochips","volume":"3","author":"Su F.","year":"2008","unstructured":"F. Su and K. Chakrabarty. 2008. High-level synthesis of digital microfluidic biochips. ACM JETC 3, 4 (2008), 1:1\u20131:32.","journal-title":"ACM JETC"},{"key":"e_1_3_1_5_2","volume-title":"Proc. of the ICCPS","author":"Loveless T.","year":"2021","unstructured":"T. Loveless, J. Ott, and P. Brisk. 2021. Time-and resource-constrained scheduling for digital microfluidic biochips. In Proc. of the ICCPS (2021), 198\u2013208."},{"key":"e_1_3_1_6_2","first-page":"10","article-title":"2021. Enhancing the reliability of MEDA biochips using IJTAG and wear leveling","volume":"40","author":"Zhong Z.","year":"2021","unstructured":"Z. Zhong, T. C. Liang, and K. Chakrabarty. 2021. Enhancing the reliability of MEDA biochips using IJTAG and wear leveling. IEEE TCAD 40, 10 (2021), 2063\u20132076.","journal-title":"IEEE TCAD"},{"key":"e_1_3_1_7_2","volume-title":"Proc. of the GLSVLSI. 509\u2013514","author":"Kundu D.","unstructured":"D. Kundu, G. S. Vamsi, K. Vivek Veman, G. Mahidhar, and S. Roy. 2023. Reinforcement learning based module placement for enhancing reliability of MEDA digital microfluidic biochips. In Proc. of the GLSVLSI. 509\u2013514."},{"key":"e_1_3_1_8_2","first-page":"4","article-title":"2023. Deep reinforcement learning-based approach for efficient and reliable droplet routing on MEDA biochips","volume":"42","author":"Elfar M.","year":"2023","unstructured":"M. Elfar, Y. C. Chang, H. H. Y. Ku, T. C. Liang, K. Chakrabarty, and M. Pajic. 2023. Deep reinforcement learning-based approach for efficient and reliable droplet routing on MEDA biochips. IEEE TCAD 42, 4 (2023), 1212\u20131222.","journal-title":"IEEE TCAD"},{"key":"e_1_3_1_9_2","volume-title":"Proc. of the CGO","author":"Curtis C.","year":"2018","unstructured":"C. Curtis, D. Grissom, and P. Brisk. 2018. A compiler for cyber-physical digital microfluidic biochips. In Proc. of the CGO (2018), 365\u2013377."},{"key":"e_1_3_1_10_2","first-page":"3","article-title":"2014. Fast online synthesis of digital microfluidic biochips","volume":"33","author":"Grissom D.","year":"2014","unstructured":"D. Grissom and P. Brisk. 2014. Fast online synthesis of digital microfluidic biochips. IEEE TCAD 33, 3 (2014), 356\u2013369.","journal-title":"IEEE TCAD"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1145\/2567669"},{"key":"e_1_3_1_12_2","volume-title":"Proc of the ISIC","author":"Alistar M.","year":"2014","unstructured":"M. Alistar and P. Pop. 2014. Online synthesis for operation execution time variability on digital microfluidic biochips. In Proc of the ISIC (2014), 356\u2013359."},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1145\/3368826.3377925"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11047-006-9032-6"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1145\/2629578"},{"key":"e_1_3_1_16_2","volume-title":"Proc. of the ASP-DAC","author":"Liang T. C.","year":"2019","unstructured":"T. C. Liang, Y. S. Chan, T. Y. Ho, K. Chakrabarty, and C. Y. Lee. 2019. Sample preparation for multiple-reactant bioassays on micro-electrode-dot-array biochips. In Proc. of the ASP-DAC (2019), 468\u2013473."},{"key":"e_1_3_1_17_2","volume-title":"Proc. of the DSD 2022","author":"Kundu D.","year":"2022","unstructured":"D. Kundu and S. Roy. 2022. MEDA biochip based single- target fluidic mixture preparation with minimum wastage. In Proc. of the DSD 2022 (2022), 809\u2013814."},{"key":"e_1_3_1_18_2","first-page":"2","article-title":"2006. Performance characterization of a reconfigurable planar-array digital microfluidic system","volume":"25","author":"Griffith E.J.","year":"2026","unstructured":"E.J. Griffith, S. Akella, and M. K. Goldberg. 2006. Performance characterization of a reconfigurable planar-array digital microfluidic system. IEEE TCAD 25, 2 (2026), 345\u2013357.","journal-title":"IEEE TCAD"},{"key":"e_1_3_1_19_2","volume-title":"Proc. of the DAC","author":"Grissom D.","year":"2012","unstructured":"D. Grissom and P. Brisk. 2012. Path scheduling on digital microfluidic biochips. In Proc. of the DAC (2012), 26\u201335."},{"key":"e_1_3_1_20_2","volume-title":"Proc. of the GLSVLSI","author":"Roy P.","year":"2010","unstructured":"P. Roy, H. Rahaman, and P. Dasgupta. 2010. A novel droplet routing algorithm for digital microfluidic biochips. In Proc. of the GLSVLSI (2010), 441\u2013446."},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-nbt.2011.0018"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1039\/c2lc40273d"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/TCAD.2020.3012746"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1145\/3446880"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1145\/2593069.2593135"},{"key":"e_1_3_1_26_2","volume-title":"Proc. of the ISDCS","author":"Keszocze O.","year":"2020","unstructured":"O. Keszocze, R. Wille, and R. Drechsler. 2020. One-pass synthesis for digital microfluidic biochips: A survey. In Proc. of the ISDCS (2020), 1\u20136."},{"key":"e_1_3_1_27_2","volume-title":"DTU Compute","author":"Minhass W. H.","year":"2012","unstructured":"W. H. Minhass, P. Pop, and J. Madsen. 2012. System-level modeling and synthesis techniques for flow-based microfluidic very large scale integration biochips. Technical Report, DTU Compute, 2012."},{"key":"e_1_3_1_28_2","unstructured":"A Beginners Guide to ChIP. 2024. Retrieved from https:\/\/docs.abcam.com\/pdf\/chromatin\/A-beginners-guide-to-ChIP.pdf. [Accessed: October 2025]."},{"key":"e_1_3_1_29_2","first-page":"18","article-title":"2016. Preparation of plasmid DNA by alkaline lysis with sodium dodecyl sulfate","volume":"2016","author":"Green M. R.","year":"2016","unstructured":"M. R. Green and J. Sambrook. 2016. Preparation of plasmid DNA by alkaline lysis with sodium dodecyl sulfate: Minipreps. Cold Spring Harbor Protocols 2016, 18 (2016), 911\u2013916.","journal-title":"Minipreps. Cold Spring Harbor Protocols"},{"key":"e_1_3_1_30_2","volume-title":"A high throughput splinkerette-PCR method for the isolation and sequencing of retroviral insertion sites. Nature Protocols 4, 5","author":"Uren A. G.","year":"2009","unstructured":"A. G. Uren, H. Mikkers, J. Kool, L. van der Weyden, A. H. Lund, C. H. Wilson, R. Rance, J. Jonkers, and M. van Lohuizen. 2009. A high throughput splinkerette-PCR method for the isolation and sequencing of retroviral insertion sites. Nature Protocols 4, 5 (2009), 789\u2013798."},{"key":"e_1_3_1_31_2","unstructured":"Openwetware. 2009. Retrieved from https:\/\/openwetware.org\/wiki\/Main_Page. [Accessed: October 2025]."},{"key":"e_1_3_1_32_2","unstructured":"ScienCell Research Laboratories. 2020. Glucose Assay. Retrieved from https:\/\/www.sciencellonline.com\/PS\/8418.pdf"},{"key":"e_1_3_1_33_2","doi-asserted-by":"publisher","DOI":"10.1145\/2898999"}],"container-title":["ACM Transactions on Design Automation of Electronic Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3774890","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T13:14:43Z","timestamp":1765977283000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3774890"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,17]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,3,31]]}},"alternative-id":["10.1145\/3774890"],"URL":"https:\/\/doi.org\/10.1145\/3774890","relation":{},"ISSN":["1084-4309","1557-7309"],"issn-type":[{"value":"1084-4309","type":"print"},{"value":"1557-7309","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,17]]},"assertion":[{"value":"2025-06-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-15","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-17","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}