{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T17:14:35Z","timestamp":1784826875274,"version":"3.55.0"},"publisher-location":"New York, NY, USA","reference-count":12,"publisher":"ACM","license":[{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/legalcode"}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5,21]]},"DOI":"10.1145\/3820709.3820726","type":"proceedings-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T16:58:41Z","timestamp":1784825921000},"page":"179-184","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A Miniaturized Tri-Axial Force Sensor with a Novel I-Beam Structure for Surgical Robotics"],"prefix":"10.1145","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-8586-053X","authenticated-orcid":false,"given":"Xingxing","family":"Li","sequence":"first","affiliation":[{"name":"State Key Laboratory of Bioelectronics and the Jiangsu Key Laboratory of Remote Measurement and Control, School of Instrument Science &amp; Engineering, Southeast University, Nanjing, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1982-6780","authenticated-orcid":false,"given":"Aiguo","family":"Song","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Bioelectronics and the Jiangsu Key Laboratory of Remote Measurement and Control, School of Instrument Science &amp; Engineering, Southeast University, Nanjing, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-0090-7569","authenticated-orcid":false,"given":"Ziyi","family":"Zhao","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Bioelectronics and the Jiangsu Key Laboratory of Remote Measurement and Control, School of Instrument Science &amp; Engineering, Southeast University, Nanjing, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-8914-697X","authenticated-orcid":false,"given":"Jingjing","family":"Xu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Bioelectronics and the Jiangsu Key Laboratory of Remote Measurement and Control, School of Instrument Science &amp; Engineering, Southeast University, Nanjing, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-7160-6204","authenticated-orcid":false,"given":"Ziheng","family":"Qiu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Bioelectronics and the Jiangsu Key Laboratory of Remote Measurement and Control, School of Instrument Science &amp; Engineering, Southeast University, Nanjing, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"key":"e_1_3_3_1_2_2","doi-asserted-by":"crossref","unstructured":"Okamura Allison M. Haptic feedback in robot-assisted minimally invasive surgery. Current opinion in urology 19(1):102\u2013107 2009.","DOI":"10.1097\/MOU.0b013e32831a478c"},{"key":"e_1_3_3_1_3_2","doi-asserted-by":"crossref","unstructured":"Lanfranco Anthony R and Castellanos Andres E and Desai Jaydev P and Meyers William C. Robotic surgery: a current perspective. Annals of surgery 239(1):14\u201321 2004.","DOI":"10.1097\/01.sla.0000103020.19595.7d"},{"key":"e_1_3_3_1_4_2","unstructured":"Fu Yili and Pan Bo. Research progress of surgical robot for minimally invasive surgery. Journal of Harbin Institute of Technology 51(1):14\u201321 2019."},{"key":"e_1_3_3_1_5_2","doi-asserted-by":"crossref","unstructured":"Dahiya Ravinder S and Metta Giorgio and Valle Maurizio and Sandini Giulio. Tactile sensing\u2014from humans to humanoids. IEEE Transactions on Robotics 26(1):1\u201320 2009.","DOI":"10.1109\/TRO.2009.2033627"},{"key":"e_1_3_3_1_6_2","unstructured":"Craig John J. Introduction to Robotics: Mechanics and Control. Pearson Education Inc 1986. 0201103265"},{"key":"e_1_3_3_1_7_2","doi-asserted-by":"crossref","unstructured":"Puangmali Pinyo and Althoefer Kaspar and Seneviratne Lakmal D and Murphy Declan and Dasgupta Prokar. State-of-the-art in force and tactile sensing for minimally invasive surgery. IEEE Sensors Journal 8(4):371\u2013381 2008.","DOI":"10.1109\/JSEN.2008.917481"},{"key":"e_1_3_3_1_8_2","unstructured":"Zhang LiJian and Hu RuiQin and Yi Wangmin. Research on Force Perception of End Load of Industrial Robots Based on Six-dimensional Force Sensors. Acta Automatica Sinica 43(3):439-447 2017."},{"key":"e_1_3_3_1_9_2","doi-asserted-by":"crossref","unstructured":"Prasad Srinivas K and Kitagawa Masaya and Fischer Gregory S and Zand Jason and Talamini Mark A and Taylor Russell H and Okamura Allison M. A modular 2-DOF force-sensing instrument for laparoscopic surgery. Lecture Notes in Computer Science 2878:279-286 2003.","DOI":"10.1007\/978-3-540-39899-8_35"},{"key":"e_1_3_3_1_10_2","doi-asserted-by":"crossref","unstructured":"Seibold U. and Kubler B. and Hirzinger G. Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability. IEEE International Conference on Robotics and Automation ICRA 496-501 2005.","DOI":"10.1109\/ROBOT.2005.1570167"},{"key":"e_1_3_3_1_11_2","doi-asserted-by":"crossref","unstructured":"Puangmali Pinyo and Liu Hongbin and Seneviratne Lakmal D and Dasgupta Prokar and Althoefer Kaspar. Miniature 3-axis distal force sensor for minimally invasive surgical palpation. Ieee\/Asme Transactions On Mechatronics 17(4):646\u2013656 2011.","DOI":"10.1109\/TMECH.2011.2116033"},{"key":"e_1_3_3_1_12_2","doi-asserted-by":"crossref","unstructured":"Song Hoseok and Kim Kiyoung and Lee Jungju. Development of optical fiber Bragg grating force-reflection sensor system of medical application for safe minimally invasive robotic surgery. Review of Scientific Instruments 82(7) 2011.","DOI":"10.1063\/1.3606502"},{"key":"e_1_3_3_1_13_2","unstructured":"Yao Bin and Zhang Jianxun and Dai Yu and Sun Huijiao. Research on decoupling method of multi-dimensional force sensor used in minimally invasive surgical robot. Chinese Journal of Scientific Instrument 41(1): 147\u2013153 2020."}],"event":{"name":"RobCE 2026: 2026 6th International Conference on Robotics and Control Engineering","location":"Hong Kong Hong Kong","acronym":"RobCE 2026"},"container-title":["Proceedings of the 6th International Conference on Robotics and Control Engineering"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3820709.3820726","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T16:59:44Z","timestamp":1784825984000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3820709.3820726"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,21]]},"references-count":12,"alternative-id":["10.1145\/3820709.3820726","10.1145\/3820709"],"URL":"https:\/\/doi.org\/10.1145\/3820709.3820726","relation":{},"subject":[],"published":{"date-parts":[[2026,5,21]]},"assertion":[{"value":"2026-07-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}