{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T17:14:40Z","timestamp":1784826880737,"version":"3.55.0"},"publisher-location":"New York, NY, USA","reference-count":7,"publisher":"ACM","license":[{"start":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T00:00:00Z","timestamp":1779321600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/legalcode"}],"funder":[{"name":"2030 Smart Grid National Key Science and Technology Project of China","award":["2026ZD0813903"],"award-info":[{"award-number":["2026ZD0813903"]}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5,21]]},"DOI":"10.1145\/3820709.3820750","type":"proceedings-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T16:58:41Z","timestamp":1784825921000},"page":"225-229","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Multi-physics Modeling and Fast Calculation of Fault Arcs Based on Experiment-Data Driven Equivalent Heat Source"],"prefix":"10.1145","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6036-3012","authenticated-orcid":false,"given":"Yingjie","family":"Yan","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0458-4878","authenticated-orcid":false,"given":"Olimjon","family":"Toirov","sequence":"additional","affiliation":[{"name":"Department of Electrical Machines, Tashkent State Technical University, Tashkent, Tashkent, Uzbekistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3724-5169","authenticated-orcid":false,"given":"Jun","family":"Deng","sequence":"additional","affiliation":[{"name":"Electric Power Research Institute, EHV Power Transmission Company of China Southern Power Grid Co., Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-8476-6100","authenticated-orcid":false,"given":"Jin","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5717-9414","authenticated-orcid":false,"given":"Zhihao","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7921-6757","authenticated-orcid":false,"given":"Yadong","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"key":"e_1_3_3_1_1_2","volume-title":"Research on an Equivalent Heat Source Model of the AC Arc in the Short Gap of a Copper-Core Cable and a Fire Risk Assessment Method. Sensors","author":"Li Y.","year":"2024","unstructured":"Li, Y.; Zhang, R.; Yang, K.; Qi, Y. Research on an Equivalent Heat Source Model of the AC Arc in the Short Gap of a Copper-Core Cable and a Fire Risk Assessment Method. Sensors 2024, 24, 1443."},{"key":"e_1_3_3_1_2_2","volume-title":"A Novel Arc Fault Detector for Early Detection of Electrical Fires. Sensors","author":"Yang K.","year":"2016","unstructured":"Yang, K.; Zhang, R.; Yang, J.; Liu, C.; Chen, S.; Zhang, F. A Novel Arc Fault Detector for Early Detection of Electrical Fires. Sensors 2016, 16, 500."},{"issue":"10","key":"e_1_3_3_1_3_2","doi-asserted-by":"crossref","first-page":"2714","DOI":"10.1109\/TPS.2014.2329997","article-title":"MHD Modeling of Fault Arc in a Closed Container","volume":"42","author":"Li Y.","year":"2014","unstructured":"M. Li, Y. Wu, Y. Wu, Y. Liu and Y. Hu, \"MHD Modeling of Fault Arc in a Closed Container,\" in IEEE Transactions on Plasma Science, vol. 42, no. 10, pp. 2714-2715, Oct. 2014.","journal-title":"IEEE Transactions on Plasma Science"},{"key":"e_1_3_3_1_4_2","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1007\/s11090-014-9536-2","article-title":"A Comparison Between MHD Modeling and Experimental Results in a 3-Phase AC Arc Plasma Torch","volume":"34","author":"Rehmet C.","year":"2014","unstructured":"Rehmet, C., Fabry, F., Rohani, V. et al. A Comparison Between MHD Modeling and Experimental Results in a 3-Phase AC Arc Plasma Torch: Influence of the Electrode Tip Geometry. Plasma Chem Plasma Process 34, 975\u2013996 (2014).","journal-title":"Influence of the Electrode Tip Geometry. Plasma Chem Plasma Process"},{"issue":"6","key":"e_1_3_3_1_5_2","doi-asserted-by":"crossref","first-page":"4549","DOI":"10.1109\/TIA.2016.2593687","article-title":"3-D Magnetohydrodynamic Modeling of DC Arc in Power System","volume":"52","author":"Rau Z.","year":"2016","unstructured":"S. -H. Rau, Z. Zhang and W. -J. Lee, \"3-D Magnetohydrodynamic Modeling of DC Arc in Power System,\" in IEEE Transactions on Industry Applications, vol. 52, no. 6, pp. 4549-4555, Nov.-Dec. 2016.","journal-title":"IEEE Transactions on Industry Applications"},{"key":"e_1_3_3_1_6_2","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.ijheatmasstransfer.2018.03.048","article-title":"2018.The research on the heat source characteristics and the equivalent heat source of the arc in gaps","volume":"124","author":"Liu K.","unstructured":"Liu, K., Yang, F., Wang, S., Gao, B., and Xu, C. 2018.The research on the heat source characteristics and the equivalent heat source of the arc in gaps. International Journal of Heat and Mass Transfer 124, 177\u2013189.","journal-title":"International Journal of Heat and Mass Transfer"},{"key":"e_1_3_3_1_7_2","first-page":"095009","article-title":"Numerical study on instantaneous heat transfer characteristics of AC arc-fault","author":"Qirong Wu","year":"2021","unstructured":"Qirong Wu, Kai Yang, Rencheng Zhang, Ran Tu, Xuejin Zhou; Numerical study on instantaneous heat transfer characteristics of AC arc-fault. AIP Advances 1 September 2021; 11 (9): 095009.","journal-title":"AIP Advances"}],"event":{"name":"RobCE 2026: 2026 6th International Conference on Robotics and Control Engineering","location":"Hong Kong Hong Kong","acronym":"RobCE 2026"},"container-title":["Proceedings of the 6th International Conference on Robotics and Control Engineering"],"original-title":[],"link":[{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3820709.3820750","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T16:59:42Z","timestamp":1784825982000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3820709.3820750"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,21]]},"references-count":7,"alternative-id":["10.1145\/3820709.3820750","10.1145\/3820709"],"URL":"https:\/\/doi.org\/10.1145\/3820709.3820750","relation":{},"subject":[],"published":{"date-parts":[[2026,5,21]]},"assertion":[{"value":"2026-07-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}