{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:01:43Z","timestamp":1790787703453,"version":"4.1.0"},"reference-count":55,"publisher":"Association for Computing Machinery (ACM)","issue":"3","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/legalcode"}],"funder":[{"DOI":"10.13039\/501100002920","name":"Research Grants Council, University Grants Committee","doi-asserted-by":"publisher","award":["Contract CERG 16205824, 16204523, SZSTI25EG20, SRFS2425-6S05, AoE\/E-601\/22-R, and HB016"],"award-info":[{"award-number":["Contract CERG 16205824, 16204523, SZSTI25EG20, SRFS2425-6S05, AoE\/E-601\/22-R, and HB016"]}],"id":[{"id":"10.13039\/501100002920","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."],"published-print":{"date-parts":[[2026,9,30]]},"abstract":"<jats:p>\n                    Cardiorespiratory fitness (CRF) is crucial for maintaining overall health, with VO\n                    <jats:sub>2<\/jats:sub>\n                    max (maximal oxygen consumption) and VO\n                    <jats:sub>2<\/jats:sub>\n                    AT (oxygen consumption at anaerobic threshold) serving as key physiological indicators. The current gold standard for assessing these metrics is Cardiopulmonary Exercise Testing (CPET), which requires bulky equipment, trained personnel, and significant time, putting it out of reach for most people. In this study, we introduce CaReFit, an innovative and low-cost system that utilizes a single-lead electrocardiogram (ECG) and muscle oxygenation (SmO\n                    <jats:sub>2<\/jats:sub>\n                    ) sensors to estimate VO\n                    <jats:sub>2<\/jats:sub>\n                    max and VO\n                    <jats:sub>2<\/jats:sub>\n                    AT. Our method leverages the coupled behavior of ECG and SmO\n                    <jats:sub>2<\/jats:sub>\n                    signals during exercise to predict these critical performance metrics. To mitigate exercise-induced noise in ECG signals, we implement a diffusion-based ECG denoising model trained with a tailored ECG-guided loss function on combined public datasets. Then, our multimodal neural network is specifically designed to leverage physiological insights for accurate CRF predictions. We conducted a deployment of CaReFit with 50 patients in a clinical setting, and evaluated CaReFit under a strict subject-disjoint protocol. Under this leakage-free evaluation, CaReFit achieves a mean absolute percentage error (MAPE) of 9.30% (95% CI: 7.06-11.80) for VO\n                    <jats:sub>2<\/jats:sub>\n                    max and 9.49% (95% CI: 7.02-12.12) for VO\n                    <jats:sub>2<\/jats:sub>\n                    AT. We further conduct a head-to-head comparison with a commercial portable device, and our system demonstrates similar VO\n                    <jats:sub>2<\/jats:sub>\n                    max performance trends under the same session protocol while additionally supporting VO\n                    <jats:sub>2<\/jats:sub>\n                    AT estimation. Furthermore, we make our dataset and evaluation code publicly available to facilitate further research and development in this domain.\n                  <\/jats:p>","DOI":"10.1145\/3831985","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T16:31:59Z","timestamp":1790785919000},"page":"1-31","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["CaReFit: Cost-Effective Cardiorespiratory Fitness Assessment Using Multimodal Sensors"],"prefix":"10.1145","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-7036-7148","authenticated-orcid":false,"given":"Chi","family":"Xu","sequence":"first","affiliation":[{"name":"Department of Computer Science and Engineering, The Hong Kong University of Science and Technology, Hong Kong, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7858-4419","authenticated-orcid":false,"given":"Wentao","family":"Xie","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Engineering, The Hong Kong University of Science and Technology, Hong Kong, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0999-2125","authenticated-orcid":false,"given":"Huaning","family":"Tan","sequence":"additional","affiliation":[{"name":"National Graduate College for Engineers, Southern University of Science and Technology, Shenzhen, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9235-6607","authenticated-orcid":false,"given":"Zirui","family":"Huang","sequence":"additional","affiliation":[{"name":"Internet of Things Thrust, The Hong Kong University of Science and Technology (Guangzhou), Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6044-4146","authenticated-orcid":false,"given":"Yanbin","family":"Gong","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Engineering, The Hong Kong University of Science and Technology, Hong Kong, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2674-0918","authenticated-orcid":false,"given":"Jin","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-7025-4473","authenticated-orcid":false,"given":"Shifang","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Pulmonary and Critical Care Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9205-1881","authenticated-orcid":false,"given":"Qian","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Computer Science and Engineering, The Hong Kong University of Science and Technology, Hong Kong, Hong Kong"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"e_1_2_1_1_1","volume-title":"New Trends and Issues Proceedings on Humanities and Social Sciences","author":"Akay Mehmet","year":"2016","unstructured":"Mehmet Akay, Fatih Abut, K\u0131ymet Kaya, Ebru Cetin, and Imdat Yarim. 2016. New regression equations for estimating the maximal oxygen uptake of college of physical education and sports students in Turkey. New Trends and Issues Proceedings on Humanities and Social Sciences (2016)."},{"key":"e_1_2_1_2_1","volume-title":"Cardiopulmonary exercise testing and its application. Postgraduate medical journal 83, 985","author":"Albouaini Khaled","year":"2007","unstructured":"Khaled Albouaini, Mohaned Egred, Albert Alahmar, and David Justin Wright. 2007. Cardiopulmonary exercise testing and its application. Postgraduate medical journal 83, 985 (2007), 675\u2013682."},{"key":"e_1_2_1_3_1","volume-title":"Estimating oxygen uptake during nonsteady-state activities and transitions using wearable sensors","author":"Altini Marco","year":"2015","unstructured":"Marco Altini, Julien Penders, and Oliver Amft. 2015. Estimating oxygen uptake during nonsteady-state activities and transitions using wearable sensors. IEEE journal of biomedical and health informatics 20, 2 (2015), 469\u2013475."},{"key":"e_1_2_1_4_1","doi-asserted-by":"crossref","first-page":"102885","DOI":"10.1016\/j.bspc.2021.102885","article-title":"Theoretical analysis of the 12 min Cooper's test to estimate the maximal oxygen uptake rate","volume":"69","author":"Alvarez-Ramirez Jos\u00e9","year":"2021","unstructured":"Jos\u00e9 Alvarez-Ramirez and Eduardo Rodriguez. 2021. Theoretical analysis of the 12 min Cooper's test to estimate the maximal oxygen uptake rate. Biomedical Signal Processing and Control 69 (2021), 102885.","journal-title":"Biomedical Signal Processing and Control"},{"key":"e_1_2_1_5_1","volume-title":"Lucieli Teresa Cambri, Ednei Luiz Antonio, Neif Murad, Marco Tulio de Mello, Alexandra Alberto Santos, Paulo de Tarso Camillo de Carvalho, Jose Antonio Silva-Junior, Danilo Sales Bocalini, et al.","author":"Arsa Gisela","year":"2018","unstructured":"Gisela Arsa, Fernanda Cordoba Lanza, Lucieli Teresa Cambri, Ednei Luiz Antonio, Neif Murad, Marco Tulio de Mello, Alexandra Alberto Santos, Paulo de Tarso Camillo de Carvalho, Jose Antonio Silva-Junior, Danilo Sales Bocalini, et al. 2018. Predicted equation for VO2 based on a 20-meter multistage shuttle run test for children. International journal of sports medicine 39, 14 (2018), 1049\u20131054."},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.imu.2022.100863"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.3390\/s25103204"},{"key":"e_1_2_1_8_1","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1111\/cpf.12438","article-title":"A new equation to predict peak VO 2 in obese patients during cardiopulmonary exercise testing","volume":"38","author":"Brisola Barbosa Alan Carlos","year":"2018","unstructured":"Alan Carlos Brisola Barbosa, Evandro Fornias Sperandio, Barbara de Barros Gonze, Giovanna Domingues Spina, Rodolfo Leite Arantes, Ant\u00f4nio Ricardo de Toledo Gagliardi, Marcello Romiti, and Victor Zuniga Dourado. 2018. A new equation to predict peak VO 2 in obese patients during cardiopulmonary exercise testing. Clinical Physiology and Functional Imaging 38, 3 (2018), 462\u2013467.","journal-title":"Clinical Physiology and Functional Imaging"},{"key":"e_1_2_1_9_1","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0002-8703(38)90860-9","article-title":"Standardization of precordial leads","volume":"15","author":"Barnes Arlie R.","year":"1938","unstructured":"Arlie R. Barnes, Harold Ensign Bennett Pardee, Paul Dudley White, Frank N. Wilson, and Charles Christian Wolferth. 1938. Standardization of precordial leads. American Heart Journal 15 (1938), 235\u2013239. https:\/\/api.semanticscholar.org\/CorpusID:56682176","journal-title":"American Heart Journal"},{"key":"e_1_2_1_10_1","volume-title":"Prediction of oxygen uptake dynamics by machine learning analysis of wearable sensors during activities of daily living. Scientific reports 7, 1","author":"Beltrame Thomas","year":"2017","unstructured":"Thomas Beltrame, Robert Amelard, Alexander Wong, and Richard L Hughson. 2017. Prediction of oxygen uptake dynamics by machine learning analysis of wearable sensors during activities of daily living. Scientific reports 7, 1 (2017), 45738."},{"key":"e_1_2_1_11_1","doi-asserted-by":"crossref","first-page":"102632","DOI":"10.1016\/j.artmed.2023.102632","article-title":"Generative adversarial networks in electrocardiogram synthesis: Recent developments and challenges","volume":"143","author":"Berger Laurenz","year":"2023","unstructured":"Laurenz Berger, Max Haberbusch, and Francesco Moscato. 2023. Generative adversarial networks in electrocardiogram synthesis: Recent developments and challenges. Artificial Intelligence in Medicine 143 (2023), 102632.","journal-title":"Artificial Intelligence in Medicine"},{"key":"e_1_2_1_12_1","first-page":"1","article-title":"Guard your heart silently: Continuous electrocardiogram waveform monitoring with wrist-worn motion sensor","volume":"6","author":"Cao Yetong","year":"2022","unstructured":"Yetong Cao, Fan Li, Huijie Chen, Xiaochen Liu, Li Zhang, and Yu Wang. 2022. Guard your heart silently: Continuous electrocardiogram waveform monitoring with wrist-worn motion sensor. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies 6, 3 (2022), 1\u201329.","journal-title":"Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"},{"key":"e_1_2_1_13_1","volume-title":"Submaximal tests for cardiorespiratory fitness. ESSA's student manual for health, exercise and sport assessment","author":"Coombes Jeff","year":"2014","unstructured":"Jeff Coombes and Chris Askew. 2014. Submaximal tests for cardiorespiratory fitness. ESSA's student manual for health, exercise and sport assessment (2014), 219\u2013235."},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1968.03140030033008"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/18.382009"},{"key":"e_1_2_1_16_1","volume-title":"Variational mode decomposition","author":"Dragomiretskiy Konstantin","year":"2013","unstructured":"Konstantin Dragomiretskiy and Dominique Zosso. 2013. Variational mode decomposition. IEEE transactions on signal processing 62, 3 (2013), 531\u2013544."},{"key":"e_1_2_1_17_1","doi-asserted-by":"crossref","first-page":"235","DOI":"10.3390\/sports11120235","article-title":"Comparison of VO2max estimations for maximal and submaximal exercise tests in apparently healthy adults","volume":"11","author":"Dugas Marc-Olivier","year":"2023","unstructured":"Marc-Olivier Dugas, P\u00e9n\u00e9lope Paradis-Desch\u00eanes, Laurie Simard, Tommy Chevrette, Patricia Blackburn, and Martin Lavalli\u00e8re. 2023. Comparison of VO2max estimations for maximal and submaximal exercise tests in apparently healthy adults. Sports 11, 12 (2023), 235.","journal-title":"Sports"},{"key":"e_1_2_1_18_1","doi-asserted-by":"crossref","first-page":"87","DOI":"10.2478\/hukin-2022-0054","article-title":"Muscle oxygen saturation breakpoints reflect ventilatory thresholds in both cycling and running","volume":"83","author":"Feldmann Andri","year":"2022","unstructured":"Andri Feldmann, Linda Ammann, Flurin G\u00e4chter, Marc Zibung, and Daniel Erlacher. 2022. Muscle oxygen saturation breakpoints reflect ventilatory thresholds in both cycling and running. Journal of human kinetics 83 (2022), 87.","journal-title":"Journal of human kinetics"},{"key":"e_1_2_1_19_1","first-page":"115001","article-title":"Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor","volume":"24","author":"Feldmann Andri","year":"2019","unstructured":"Andri Feldmann, Roger Schmitz, and Daniel Erlacher. 2019. Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor. Journal of biomedical optics 24, 11 (2019), 115001\u2013115001.","journal-title":"Journal of biomedical optics"},{"key":"e_1_2_1_20_1","series-title":"Series B: Biological Sciences 352, 1354","volume-title":"Oxidative metabolism in muscle. Philosophical Transactions of the Royal Society of London","author":"Ferrari Marco","year":"1997","unstructured":"Marco Ferrari, Tiziano Binzoni, and Valentina Quaresima. 1997. Oxidative metabolism in muscle. Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences 352, 1354 (1997), 677\u2013683."},{"key":"e_1_2_1_21_1","volume-title":"International journal of environmental research and public health 18, 7","author":"Goncalves Catarina","year":"2021","unstructured":"Catarina Goncalves, Armando Raimundo, Ana Abreu, and Jorge Bravo. 2021. Exercise intensity in patients with cardiovascular diseases: systematic review with meta-analysis. International journal of environmental research and public health 18, 7 (2021), 3574."},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pdig.0000082"},{"key":"e_1_2_1_23_1","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.amjcard.2023.11.061","article-title":"A reference equation for peak oxygen uptake for pediatric patients who undergo treadmill cardiopulmonary exercise testing","volume":"212","author":"Griffith Garett J","year":"2024","unstructured":"Garett J Griffith, Alan P Wang, Robert I Liem, Michael R Carr, Tyler Corson, and Kendra Ward. 2024. A reference equation for peak oxygen uptake for pediatric patients who undergo treadmill cardiopulmonary exercise testing. The American Journal of Cardiology 212 (2024), 41\u201347.","journal-title":"The American Journal of Cardiology"},{"key":"e_1_2_1_24_1","volume-title":"Ricardo Stein, Claudio Gil Soares de Ara\u00fajo, Mauricio Milani","author":"Herdy Artur Haddad","year":"2016","unstructured":"Artur Haddad Herdy, Luiz Eduardo Fonteles Ritt, Ricardo Stein, Claudio Gil Soares de Ara\u00fajo, Mauricio Milani, Romeu S\u00e9rgio Meneghelo, Almir S\u00e9rgio Ferraz, Carlos Hossri, Antonio Eduardo Monteiro de Almeida, Miguel Morita Fernandes-Silva, et al. 2016. Cardiopulmonary exercise test: background, applicability and interpretation. Arquivos brasileiros de cardiologia 107, 5 (2016), 467\u2013481."},{"key":"e_1_2_1_25_1","volume-title":"Denoising diffusion probabilistic models. Advances in neural information processing systems 33","author":"Ho Jonathan","year":"2020","unstructured":"Jonathan Ho, Ajay Jain, and Pieter Abbeel. 2020. Denoising diffusion probabilistic models. Advances in neural information processing systems 33 (2020), 6840\u20136851."},{"key":"e_1_2_1_26_1","volume-title":"Cardiorespiratory fitness and cardiovascular disease-the past, present, and future. Progress in cardiovascular diseases 62, 2","author":"Kaminsky Leonard A","year":"2019","unstructured":"Leonard A Kaminsky, Ross Arena, \u00d8yvind Ellingsen, Matthew P Harber, Jonathan Myers, Cemal Ozemek, and Robert Ross. 2019. Cardiorespiratory fitness and cardiovascular disease-the past, present, and future. Progress in cardiovascular diseases 62, 2 (2019), 86\u201393."},{"key":"e_1_2_1_27_1","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1111\/j.1365-2044.2008.05690.x","article-title":"Reliability of the anaerobic threshold in cardiopulmonary exercise testing of patients with abdominal aortic aneurysms","volume":"64","author":"Kothmann Elke","year":"2009","unstructured":"Elke Kothmann, Gerard Danjoux, SJ Owen, A Parry, AJ Turley, and AM Batterham. 2009. Reliability of the anaerobic threshold in cardiopulmonary exercise testing of patients with abdominal aortic aneurysms. Anaesthesia 64, 1 (2009), 9\u201313.","journal-title":"Anaesthesia"},{"key":"e_1_2_1_28_1","first-page":"5081","article-title":"Descod-ecg: Deep score-based diffusion model for ecg baseline wander and noise removal","volume":"28","author":"Li Huayu","year":"2023","unstructured":"Huayu Li, Gregory Ditzler, Janet Roveda, and Ao Li. 2023. Descod-ecg: Deep score-based diffusion model for ecg baseline wander and noise removal. IEEE Journal of Biomedical and Health Informatics 28, 9 (2023), 5081\u20135091.","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"key":"e_1_2_1_29_1","doi-asserted-by":"publisher","DOI":"10.1145\/3770655"},{"key":"e_1_2_1_30_1","unstructured":"George Moody. 1999. MIT-BIH Normal Sinus Rhythm Database. https:\/\/www.physionet.org\/content\/nsrdb\/1.0.0\/ Accessed: 2026-01-27."},{"key":"e_1_2_1_31_1","unstructured":"George Moody and Roger Mark. 1999. MIT-BIH Noise Stress Test Database. https:\/\/www.physionet.org\/content\/nstdb\/1.0.0\/ Accessed: 2026-01-27."},{"key":"e_1_2_1_32_1","article-title":"Muscle oxygenation applications to endurance training","volume":"1","author":"Myers C","year":"2020","unstructured":"C Myers. 2020. Muscle oxygenation applications to endurance training. Anatomy & Physiology: Open Access Journal 1, 1 (2020).","journal-title":"Anatomy & Physiology: Open Access Journal"},{"key":"e_1_2_1_33_1","unstructured":"Antonio Pelliccia Sanjay Sharma Sabiha Gati Maria B\u00e4ck Mats B\u00f6rjesson Stefano Caselli Jean-Philippe Collet Domenico Corrado Jonathan A Drezner Martin Halle et al. 2021. 2020 ESC Guidelines on sports cardiology and exercise in patients with cardiovascular disease: The Task Force on sports cardiology and exercise in patients with cardiovascular disease of the European Society of Cardiology (ESC). European heart journal 42 1 (2021) 17\u201396."},{"key":"e_1_2_1_34_1","doi-asserted-by":"crossref","first-page":"e015117","DOI":"10.1161\/JAHA.119.015117","article-title":"Accuracy of nonexercise prediction equations for assessing longitudinal changes to cardiorespiratory fitness in apparently healthy adults: BALL ST cohort","volume":"9","author":"Peterman James E","year":"2020","unstructured":"James E Peterman, Matthew P Harber, Mary T Imboden, Mitchell H Whaley, Bradley S Fleenor, Jonathan Myers, Ross Arena, W Holmes Finch, and Leonard A Kaminsky. 2020. Accuracy of nonexercise prediction equations for assessing longitudinal changes to cardiorespiratory fitness in apparently healthy adults: BALL ST cohort. Journal of the American Heart Association 9, 11 (2020), e015117.","journal-title":"Journal of the American Heart Association"},{"key":"e_1_2_1_35_1","doi-asserted-by":"crossref","first-page":"2461","DOI":"10.1007\/s00421-025-05794-2","article-title":"Neuromuscular, cardiometabolic, and perceptual responses to a short sprint interval training session with different cycling torques","volume":"125","author":"Riesco-Villar Jos\u00e9","year":"2025","unstructured":"Jos\u00e9 Riesco-Villar, Aar\u00f3n Escribano-Pascual, Alejandro Gonz\u00e1lez-Fern\u00e1ndez, H\u00e9ctor Pascual-Redondo, Marina Gil-Calvo, and Daniel Boullosa. 2025. Neuromuscular, cardiometabolic, and perceptual responses to a short sprint interval training session with different cycling torques. European Journal of Applied Physiology 125, 9 (2025), 2461\u20132475.","journal-title":"European Journal of Applied Physiology"},{"key":"e_1_2_1_36_1","doi-asserted-by":"publisher","DOI":"10.1145\/3638550.3641136"},{"key":"e_1_2_1_37_1","first-page":"e653","article-title":"Importance of assessing cardiorespiratory fitness in clinical practice: a case for fitness as a clinical vital sign: a scientific statement from the American Heart Association","volume":"134","author":"Ross Robert","year":"2016","unstructured":"Robert Ross, Steven N Blair, Ross Arena, Timothy S Church, Jean-Pierre Despr\u00e9s, Barry A Franklin, William L Haskell, Leonard A Kaminsky, Benjamin D Levine, Carl J Lavie, et al. 2016. Importance of assessing cardiorespiratory fitness in clinical practice: a case for fitness as a clinical vital sign: a scientific statement from the American Heart Association. Circulation 134, 24 (2016), e653-e699.","journal-title":"Circulation"},{"key":"e_1_2_1_38_1","doi-asserted-by":"crossref","first-page":"12649","DOI":"10.1038\/s41598-023-39651-z","article-title":"Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis","volume":"13","author":"Sendra-Perez Carlos","year":"2023","unstructured":"Carlos Sendra-Perez, Jose Luis Sanchez-Jimenez, Joaquin Martin Marzano-Felisatti, Alberto Encarnacion-Martinez, Rosario Salvador-Palmer, and Jose I Priego-Quesada. 2023. Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis. Scientific Reports 13, 1 (2023), 12649.","journal-title":"Scientific Reports"},{"key":"e_1_2_1_39_1","volume-title":"Mozziyar Etemadi, Aaron Young, Thomas Pl\u00f6tz, and Omer T Inan.","author":"Hasan Shandhi Md Mobashir","year":"2020","unstructured":"Md Mobashir Hasan Shandhi, William H Bartlett, James Alex Heller, Mozziyar Etemadi, Aaron Young, Thomas Pl\u00f6tz, and Omer T Inan. 2020. Estimation of instantaneous oxygen uptake during exercise and daily activities using a wearable cardio-electromechanical and environmental sensor. IEEE journal of biomedical and health informatics 25, 3 (2020), 634\u2013646."},{"key":"e_1_2_1_40_1","first-page":"341","article-title":"The diagnostic value of exercise stress testing for cardiovascular disease is more than just st segment changes: A review","volume":"2","author":"Sharif Salaheddin","year":"2016","unstructured":"Salaheddin Sharif and Stephen E Alway. 2016. The diagnostic value of exercise stress testing for cardiovascular disease is more than just st segment changes: A review. J Integr Cardiol 2, 4 (2016), 341\u2013355.","journal-title":"J Integr Cardiol"},{"key":"e_1_2_1_41_1","doi-asserted-by":"crossref","first-page":"e0319760","DOI":"10.1371\/journal.pone.0319760","article-title":"Estimating oxygen uptake in simulated team sports using machine learning models and wearable sensor data: A pilot study","volume":"20","author":"Sheridan Dermot","year":"2025","unstructured":"Dermot Sheridan, Arne Jaspers, Dinh Viet Cuong, Tim Op De Be\u00e9ck, Niall M Moyna, Toon T de Beukelaar, and Mark Roantree. 2025. Estimating oxygen uptake in simulated team sports using machine learning models and wearable sensor data: A pilot study. Plos One 20, 4 (2025), e0319760.","journal-title":"Plos One"},{"key":"e_1_2_1_42_1","volume-title":"Muscle oxygenation kinetics at the onset of exercise do not depend on exercise intensity. European journal of applied physiology 91","author":"Tanaka Junya","year":"2004","unstructured":"Ken-ichi Shibuya, Junya Tanaka, and Tetsuro Ogaki. 2004. Muscle oxygenation kinetics at the onset of exercise do not depend on exercise intensity. European journal of applied physiology 91 (2004), 712\u2013715."},{"key":"e_1_2_1_43_1","volume-title":"Denoising Diffusion Implicit Models. In 9th International Conference on Learning Representations, ICLR 2021","author":"Song Jiaming","year":"2021","unstructured":"Jiaming Song, Chenlin Meng, and Stefano Ermon. 2021. Denoising Diffusion Implicit Models. In 9th International Conference on Learning Representations, ICLR 2021, Virtual Event, Austria, May 3-7, 2021. OpenReview.net. https:\/\/openreview.net\/forum?id=St1giarCHLP"},{"key":"e_1_2_1_44_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICASSP.2011.5947265"},{"key":"e_1_2_1_45_1","volume-title":"Estimation of VO2max from the ratio between HR max and HR rest-the Heart Rate Ratio Method. European journal of applied physiology 91","author":"Uth Niels","year":"2004","unstructured":"Niels Uth, Henrik S\u00f8rensen, Kristian Overgaard, and Preben K Pedersen. 2004. Estimation of VO2max from the ratio between HR max and HR rest-the Heart Rate Ratio Method. European journal of applied physiology 91 (2004), 111\u2013115."},{"key":"e_1_2_1_46_1","volume-title":"2024 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES). IEEE, 266\u2013271","author":"Vaishnavi CK","year":"2024","unstructured":"CK Vaishnavi, V Sricharan, G Sri Gayathri, N Danush Adhithya, SP Preejith, et al. 2024. Optimizing VO 2 max Prediction in Gamified Cardiac Assessment: Leveraging Effective Feature Selection and Refined Protocols for Robust Models. In 2024 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES). IEEE, 266\u2013271."},{"key":"e_1_2_1_47_1","doi-asserted-by":"crossref","first-page":"e14490","DOI":"10.1111\/sms.14490","article-title":"Accuracy of respiratory gas variables, substrate, and energy use from 15 CPET systems during simulated and human exercise","volume":"34","author":"Hooren Bas Van","year":"2024","unstructured":"Bas Van Hooren, Tjeu Souren, and Bart C Bongers. 2024. Accuracy of respiratory gas variables, substrate, and energy use from 15 CPET systems during simulated and human exercise. Scandinavian Journal of Medicine & Science in Sports 34, 1 (2024), e14490.","journal-title":"Scandinavian Journal of Medicine & Science in Sports"},{"key":"e_1_2_1_48_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3610871","article-title":"Knowing your heart condition anytime: User-independent ECG measurement using commercial mobile phones","volume":"7","author":"Wang Lei","year":"2023","unstructured":"Lei Wang, Xingwei Wang, Dalin Zhang, Xiaolei Ma, Yong Zhang, Haipeng Dai, Chenren Xu, Zhijun Li, and Tao Gu. 2023. Knowing your heart condition anytime: User-independent ECG measurement using commercial mobile phones. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies 7, 3 (2023), 1\u201328.","journal-title":"Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"},{"key":"e_1_2_1_49_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3569503","article-title":"ECG-grained cardiac monitoring using uwb signals","volume":"6","author":"Wang Zhi","year":"2023","unstructured":"Zhi Wang, Beihong Jin, Siheng Li, Fusang Zhang, and Wenbo Zhang. 2023. ECG-grained cardiac monitoring using uwb signals. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies 6, 4 (2023), 1\u201325.","journal-title":"Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"},{"key":"e_1_2_1_50_1","doi-asserted-by":"crossref","first-page":"e0166608","DOI":"10.1371\/journal.pone.0166608","article-title":"How accurate is the prediction of maximal oxygen uptake with treadmill testing","volume":"11","author":"Wicks John R","year":"2016","unstructured":"John R Wicks and Neil B Oldridge. 2016. How accurate is the prediction of maximal oxygen uptake with treadmill testing? PLoS One 11, 11 (2016), e0166608.","journal-title":"PLoS One"},{"key":"e_1_2_1_51_1","doi-asserted-by":"crossref","first-page":"e0280897","DOI":"10.1371\/journal.pone.0280897","article-title":"External validation of VO2max prediction models based on recreational and elite endurance athletes","volume":"18","author":"Wiecha Szczepan","year":"2023","unstructured":"Szczepan Wiecha, Przemys\u0142aw Seweryn Kasiak, Igor Cie\u015bli\u0144ski, Tim Takken, Tomasz Palka, Beat Knechtle, Pantelis T Nikolaidis, \u0141ukasz A Ma\u0142ek, Marek Postu\u0142a, Artur Mamcarz, et al. 2023. External validation of VO2max prediction models based on recreational and elite endurance athletes. PLoS One 18, 1 (2023), e0280897.","journal-title":"PLoS One"},{"key":"e_1_2_1_52_1","doi-asserted-by":"crossref","first-page":"758589","DOI":"10.3389\/fcvm.2021.758589","article-title":"Population and age-based cardiorespiratory fitness level investigation and automatic prediction","volume":"8","author":"Xiang Liangliang","year":"2022","unstructured":"Liangliang Xiang, Kaili Deng, Qichang Mei, Zixiang Gao, Tao Yang, Alan Wang, Justin Fernandez, and Yaodong Gu. 2022. Population and age-based cardiorespiratory fitness level investigation and automatic prediction. Frontiers in Cardiovascular Medicine 8 (2022), 758589.","journal-title":"Frontiers in Cardiovascular Medicine"},{"key":"e_1_2_1_53_1","doi-asserted-by":"publisher","DOI":"10.1145\/3678519"},{"key":"e_1_2_1_54_1","volume-title":"International conference on machine learning. 5453\u20135462","author":"Xu Keyulu","year":"2018","unstructured":"Keyulu Xu, Chengtao Li, Yonglong Tian, Tomohiro Sonobe, Ken-ichi Kawarabayashi, and Stefanie Jegelka. 2018. Representation learning on graphs with jumping knowledge networks. In International conference on machine learning. 5453\u20135462."},{"key":"e_1_2_1_55_1","unstructured":"Jhang Yu-Syuan. 2022. MIT-BIH NSRDB with NSTDB EM Noise. https:\/\/www.kaggle.com\/datasets\/yusyuanjhang\/mitbih-nsrdb-with-nstdb-em-noise Accessed: 2026-01-27."}],"container-title":["Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3831985","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T16:36:19Z","timestamp":1790786179000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3831985"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":55,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9,30]]}},"alternative-id":["10.1145\/3831985"],"URL":"https:\/\/doi.org\/10.1145\/3831985","relation":{},"ISSN":["2474-9567"],"issn-type":[{"value":"2474-9567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"assertion":[{"value":"2026-09-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}