{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:01:34Z","timestamp":1790787694320,"version":"4.1.0"},"reference-count":92,"publisher":"Association for Computing Machinery (ACM)","issue":"3","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/legalcode"}],"funder":[{"DOI":"10.13039\/100000001","name":"NSF","doi-asserted-by":"publisher","award":["2520377"],"award-info":[{"award-number":["2520377"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"NSF","doi-asserted-by":"publisher","award":["2401415"],"award-info":[{"award-number":["2401415"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"publisher","award":["24CDA1049224"],"award-info":[{"award-number":["24CDA1049224"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["dl.acm.org"],"crossmark-restriction":true},"short-container-title":["Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."],"published-print":{"date-parts":[[2026,9,30]]},"abstract":"<jats:p>\n                    This paper introduces CardioTattoo, a system that enables continuous ECG monitoring from commercial smartwatches using ultrathin graphene electronic tattoos. While smartwatches like the Apple Watch bring medical-grade ECG hardware to over 100 million wrists, they require users to stop, touch the crown, and wait 30 seconds for each reading\u2014making continuous monitoring impossible. CardioTattoo overcomes this limitation through the\n                    <jats:italic toggle=\"yes\">CardioTattoo principle:<\/jats:italic>\n                    rather than fighting the instability of textile-skin electrode interfaces, we relocate it to a motion-robust metal-metal junction. An imperceptible graphene tattoo (300nm thick) conforms to the skin and connects via a thin gold interconnect to a textile electrode on a garment's elastic cuff, routing the signal to the opposite wrist where the smartwatch completes the circuit. In head-to-head comparison on unmodified Apple Watches, CardioTattoo achieves 93% measurement success during walking versus 82% for manual crown touch, with around 2\u00d7 tighter agreement to ground truth. Across nine daily activities with 15 participants, timing-based ECG metrics remain within clinical thresholds (20ms), and longitudinal deployment over 6-8 hours demonstrates sustained performance: &gt;96% R-peak detection, &gt;80% ECG availability, and 1.42ms HRV error. A formative survey (N=99) confirms user acceptance, with 84% willing to adopt an imperceptible tattoo compared to just 6% for gel electrodes or chest straps, and study participants rated the system above 8\/10 across all usability dimensions, including comfort, unobtrusiveness, and willingness to wear.\n                  <\/jats:p>","DOI":"10.1145\/3832035","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T16:31:59Z","timestamp":1790785919000},"page":"1-36","update-policy":"https:\/\/doi.org\/10.1145\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["CardioTattoo: Unlocking Continuous ECG from Commercial Smartwatches with Ultrathin Graphene Tattoos"],"prefix":"10.1145","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6867-1431","authenticated-orcid":false,"given":"Zhenyu","family":"Lei","sequence":"first","affiliation":[{"name":"Manning College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-9515-5894","authenticated-orcid":false,"given":"Pritom","family":"Chowdhury","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-4530-9930","authenticated-orcid":false,"given":"Sean","family":"Morris","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8078-4463","authenticated-orcid":false,"given":"Phuc","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Manning College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1499-5435","authenticated-orcid":false,"given":"Dmitry","family":"Kireev","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2762-9194","authenticated-orcid":false,"given":"Deepak","family":"Ganesan","sequence":"additional","affiliation":[{"name":"Manning College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, Massachusetts, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"320","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"e_1_2_2_1_1","doi-asserted-by":"publisher","DOI":"10.3390\/electronics8050479"},{"key":"e_1_2_2_2_1","volume-title":"Deep recurrent neural networks for ECG signal denoising. arXiv preprint arXiv:1807.11551","author":"Antczak Karol","year":"2018","unstructured":"Karol Antczak. 2018. Deep recurrent neural networks for ECG signal denoising. arXiv preprint arXiv:1807.11551 (2018)."},{"key":"e_1_2_2_3_1","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1016\/j.hrthm.2021.03.044","article-title":"Validation of an algorithm for continuous monitoring of atrial fibrillation using a consumer smartwatch","volume":"18","author":"Avram Robert","year":"2021","unstructured":"Robert Avram, Mattheus Ramsis, Ashley D Cristal, Viswam Nathan, Li Zhu, Jacob Kim, Jilong Kuang, Alex Gao, Eric Vittinghoff, Linnea Rohdin-Bibby, et al. 2021. Validation of an algorithm for continuous monitoring of atrial fibrillation using a consumer smartwatch. Heart Rhythm 18, 9 (2021), 1482\u20131490.","journal-title":"Heart Rhythm"},{"key":"e_1_2_2_4_1","volume-title":"Yong Gyu Lim, and Kwang Suk Park.","author":"Baek Hyun Jae","year":"2012","unstructured":"Hyun Jae Baek, Hong Ji Lee, Yong Gyu Lim, and Kwang Suk Park. 2012. Conductive polymer foam surface improves the performance of a capacitive EEG electrode. IEEE transactions on biomedical engineering 59, 12 (2012), 3422\u20133431."},{"key":"e_1_2_2_5_1","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1002\/joa3.12035","article-title":"Portable out-of-hospital electrocardiography: A review of current technologies","volume":"34","author":"Bansal Agam","year":"2018","unstructured":"Agam Bansal and Rajnish Joshi. 2018. Portable out-of-hospital electrocardiography: A review of current technologies. Journal of arrhythmia 34, 2 (2018), 129\u2013138.","journal-title":"Journal of arrhythmia"},{"key":"e_1_2_2_6_1","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1111\/j.1651-2227.2010.02097.x","article-title":"Avoiding hyperoxemia during neonatal resuscitation: time to response of different SpO2 monitors","volume":"100","author":"Baquero Hernando","year":"2011","unstructured":"Hernando Baquero, Ramiro Alviz, Armando Castillo, Fredy Neira, and Augusto Sola. 2011. Avoiding hyperoxemia during neonatal resuscitation: time to response of different SpO2 monitors. Acta Paediatrica 100, 4 (2011), 515\u2013518.","journal-title":"Acta Paediatrica"},{"key":"e_1_2_2_7_1","volume-title":"Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. The American journal of medicine 127, 1","author":"Barrett Paddy M","year":"2014","unstructured":"Paddy M Barrett, Ravi Komatireddy, Sharon Haaser, Sarah Topol, Judith Sheard, Jackie Encinas, Angela J Fought, and Eric J Topol. 2014. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. The American journal of medicine 127, 1 (2014), 95-e11."},{"key":"e_1_2_2_8_1","volume-title":"Ultrahigh electron mobility in suspended graphene. Solid state communications 146, 9-10","author":"Bolotin Kirill I","year":"2008","unstructured":"Kirill I Bolotin, KJ Sikes, Zhifang Jiang, M Klima, G Fudenberg, James Hone, Phaly Kim, and Horst L Stormer. 2008. Ultrahigh electron mobility in suspended graphene. Solid state communications 146, 9-10 (2008), 351\u2013355."},{"key":"e_1_2_2_9_1","volume-title":"Comparison of Holter with Zio patch electrocardiography monitoring in children. The American journal of cardiology 125, 5","author":"Bolourchi Meena","year":"2020","unstructured":"Meena Bolourchi, Eric S Silver, David Muwanga, Esteban Mendez, and Leonardo Liberman. 2020. Comparison of Holter with Zio patch electrocardiography monitoring in children. The American journal of cardiology 125, 5 (2020), 767\u2013771."},{"key":"e_1_2_2_10_1","first-page":"1","article-title":"Guard your heart silently: Continuous electrocardiogram waveform monitoring with wrist-worn motion sensor","volume":"6","author":"Cao Yetong","year":"2022","unstructured":"Yetong Cao, Fan Li, Huijie Chen, Xiaochen Liu, Li Zhang, and Yu Wang. 2022. Guard your heart silently: Continuous electrocardiogram waveform monitoring with wrist-worn motion sensor. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies 6, 3 (2022), 1\u201329.","journal-title":"Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"},{"key":"e_1_2_2_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2019.2912036"},{"key":"e_1_2_2_12_1","doi-asserted-by":"crossref","unstructured":"Gari D Clifford Francisco Azuaje Patrick Mcsharry et al. 2006. ECG statistics noise artifacts and missing data. Advanced methods and tools for ECG data analysis 6 1 (2006) 18.","DOI":"10.1186\/1475-925X-6-18"},{"key":"e_1_2_2_13_1","volume-title":"Retrieved","author":"Clinic Mayo","year":"2024","unstructured":"Mayo Clinic. 2024. Holter monitor. Retrieved August, 2025 from https:\/\/www.mayoclinic.org\/tests-procedures\/holter-monitor\/about\/pac-20385039"},{"key":"e_1_2_2_14_1","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.5334\/jors.86","article-title":"Ecg-kit: A Matlab toolbox for cardiovascular signal processing","volume":"4","author":"Demski Andr\u00e9s Julio","year":"2016","unstructured":"Andr\u00e9s Julio Demski and Mariano Llamedo Soria. 2016. Ecg-kit: A Matlab toolbox for cardiovascular signal processing. Journal of open research software 4, 1 (2016), e8-e8.","journal-title":"Journal of open research software"},{"key":"e_1_2_2_15_1","doi-asserted-by":"publisher","DOI":"10.3390\/s18082414"},{"key":"e_1_2_2_16_1","volume-title":"Retrieved","year":"2021","unstructured":"ECGWaves. 2021. Clinical ECG Interpretation. Retrieved November, 2025 from https:\/\/ecgwaves.com\/course\/the-ecg-book\/"},{"key":"e_1_2_2_17_1","volume-title":"Retrieved","author":"Electro Polar","year":"2025","unstructured":"Polar Electro. 2025. Polar H10 Chestband. Retrieved August, 2025 from https:\/\/www.polar.com\/us-en\/sensors\/h10-heart-rate-sensor\/?srsltid=AfmBOoqYDuFo4uMMWX8t6MdW5oFfwL0Z0cOxFYG9E64DM4o0Fa1h9Uae"},{"key":"e_1_2_2_18_1","volume-title":"Physiology-Informed ECG Delineation Based on Peak Prominence. In 2024 32nd European Signal Processing Conference (EUSIPCO). IEEE, 1402\u20131406","author":"Emrich Jonas","year":"2024","unstructured":"Jonas Emrich, Andrea Gargano, Taulant Koka, and Michael Muma. 2024. Physiology-Informed ECG Delineation Based on Peak Prominence. In 2024 32nd European Signal Processing Conference (EUSIPCO). IEEE, 1402\u20131406."},{"key":"e_1_2_2_19_1","doi-asserted-by":"crossref","first-page":"3651","DOI":"10.3390\/s20133651","article-title":"Dry electrodes for human bioelectrical signal monitoring","volume":"20","author":"Fu Yulin","year":"2020","unstructured":"Yulin Fu, Jingjing Zhao, Ying Dong, and Xiaohao Wang. 2020. Dry electrodes for human bioelectrical signal monitoring. Sensors 20, 13 (2020), 3651.","journal-title":"Sensors"},{"key":"e_1_2_2_20_1","volume-title":"Feasibility of a T-shirt-type wearable electrocardiography monitor for detection of covert atrial fibrillation in young healthy adults. Scientific reports 9, 1","author":"Fukuma Nobuaki","year":"2019","unstructured":"Nobuaki Fukuma, Eriko Hasumi, Katsuhito Fujiu, Kayo Waki, Tsuguyoshi Toyooka, Issei Komuro, and Kazuhiko Ohe. 2019. Feasibility of a T-shirt-type wearable electrocardiography monitor for detection of covert atrial fibrillation in young healthy adults. Scientific reports 9, 1 (2019), 11768."},{"key":"e_1_2_2_21_1","volume-title":"Electrocardiographic patch devices and contemporary wireless cardiac monitoring. Frontiers in physiology 6","author":"Fung Erik","year":"2015","unstructured":"Erik Fung, Marjo-Riitta J\u00e4rvelin, Rahul N Doshi, Jerold S Shinbane, Steven K Carlson, Luanda P Grazette, Philip M Chang, Rajbir S Sangha, Heikki V Huikuri, and Nicholas S Peters. 2015. Electrocardiographic patch devices and contemporary wireless cardiac monitoring. Frontiers in physiology 6 (2015), 149."},{"key":"e_1_2_2_22_1","volume-title":"Graphene: status and prospects. science 324, 5934","author":"Geim Andre Konstantin","year":"2009","unstructured":"Andre Konstantin Geim. 2009. Graphene: status and prospects. science 324, 5934 (2009), 1530\u20131534."},{"key":"e_1_2_2_23_1","volume-title":"Retrieved","author":"Movisens","year":"2025","unstructured":"Movisens GmbH. 2025. Movisens EcgMove 4 chestband. Retrieved August, 2025 from https:\/\/www.movisens.com\/en\/products\/ecg-sensor\/"},{"key":"e_1_2_2_24_1","volume-title":"Leon Glass, Jeffrey M Hausdorff, Plamen Ch Ivanov, Roger G Mark, Joseph E Mietus, George B Moody, Chung-Kang Peng, and H Eugene Stanley.","author":"Goldberger Ary L","year":"2000","unstructured":"Ary L Goldberger, Luis AN Amaral, Leon Glass, Jeffrey M Hausdorff, Plamen Ch Ivanov, Roger G Mark, Joseph E Mietus, George B Moody, Chung-Kang Peng, and H Eugene Stanley. 2000. PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. circulation 101, 23 (2000), e215-e220."},{"key":"e_1_2_2_25_1","volume-title":"The physionet QT database: Study on the reliability of P-wave manual annotations under noisy recordings. In 2017 Computing in Cardiology (CinC)","author":"Gonz\u00e1lez Francisco","unstructured":"Francisco Gonz\u00e1lez, Ra\u00fal Alcaraz, and Jos\u00e9 J Rieta. 2017. The physionet QT database: Study on the reliability of P-wave manual annotations under noisy recordings. In 2017 Computing in Cardiology (CinC). IEEE, 1\u20134."},{"key":"e_1_2_2_26_1","volume-title":"Retrieved","author":"Health Cardinal","year":"2025","unstructured":"Cardinal Health. 2025. Kendall 100 Series Foam Electrodes. Retrieved August, 2025 from https:\/\/www.cardinalhealth.com\/en\/product-solutions\/medical\/patient-monitoring\/electrocardiography\/neonatal-and-pediatric-ecg-electrodes\/kendall-100-series-foam-electrodes.html"},{"key":"e_1_2_2_27_1","volume-title":"Retrieved","year":"2025","unstructured":"Healthcare4all. 2025. Lepu TH12 Professional Telehealth Wearable Holter 24 Hour ECG Monitor. Retrieved August, 2025 from https:\/\/us-healthcare4all.glopalstore.com\/lepu-th12-professional-telehealth-wearable-holter-24-hour-ecg-monitor?gad_source=1&gad_campaignid=17756578009&gclid=Cj0KCQjw_L_FBhDmARIsAItqgt7oSZNy_TTnZlZLmaswTF9wqxrjr5b9YYXNtAuvzMgtEij0dDNXjLQaAgIeEALw_wcB"},{"key":"e_1_2_2_28_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.134.3486.1214"},{"key":"e_1_2_2_29_1","volume-title":"MECG-E: Mamba-based ECG Enhancer for Baseline Wander Removal. In 2024 IEEE International Conference on Big Data (BigData). IEEE, 6469\u20136475","author":"Hung Kuo-Hsuan","year":"2024","unstructured":"Kuo-Hsuan Hung, Kuan-Chen Wang, Kai-Chun Liu, Wei-Lun Chen, Xugang Lu, Yu Tsao, and Chii-Wann Lin. 2024. MECG-E: Mamba-based ECG Enhancer for Baseline Wander Removal. In 2024 IEEE International Conference on Big Data (BigData). IEEE, 6469\u20136475."},{"key":"e_1_2_2_30_1","volume-title":"Retrieved","author":"Apple Inc.","year":"2025","unstructured":"Apple Inc. 2025. Apple Watch series 10. Retrieved August, 2025 from https:\/\/www.apple.com\/apple-watch-series-10\/"},{"key":"e_1_2_2_31_1","volume-title":"Retrieved","author":"Emglare Inc.","year":"2025","unstructured":"Emglare Inc. 2025. Sport T-shirt. Retrieved August, 2025 from https:\/\/emglare.com\/products\/sport-tshirt"},{"key":"e_1_2_2_32_1","volume-title":"Retrieved","author":"Google Inc.","year":"2025","unstructured":"Google Inc. 2025. Google Pixel Watch 3. Retrieved August, 2025 from https:\/\/store.google.com\/product\/pixel_watch_3?hl=en-US"},{"key":"e_1_2_2_33_1","volume-title":"Retrieved","author":"Insight Cardiac","year":"2025","unstructured":"Cardiac Insight. 2025. Cardea Solo. Retrieved August, 2025 from https:\/\/www.cardiacinsightinc.com\/cardea-solo\/for-researchers\/?gad_source=1&gad_campaignid=22382943520&gclid=Cj0KCQjwn8XFBhCxARIsAMyH8Btp6puLX2ZgJkk7Hgpq7sjEtbDmqhJxaHsBxVvc0uI73WTP6bGV4k8aAsceEALwcB"},{"key":"e_1_2_2_34_1","volume-title":"Retrieved","author":"RHYTHM.","year":"2025","unstructured":"iRHYTHM. 2025. Zio Patch. Retrieved August, 2025 from https:\/\/www.irhythmtech.com\/us\/en\/patients\/how-zio-works"},{"key":"e_1_2_2_35_1","volume-title":"Graphene electronic tattoo sensors. ACS nano 11, 8","author":"Ameri Shideh Kabiri","year":"2017","unstructured":"Shideh Kabiri Ameri, Rebecca Ho, Hongwoo Jang, Li Tao, Youhua Wang, Liu Wang, David M Schnyer, Deji Akinwande, and Nanshu Lu. 2017. Graphene electronic tattoo sensors. ACS nano 11, 8 (2017), 7634\u20137641."},{"key":"e_1_2_2_36_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41586-025-09255-w"},{"key":"e_1_2_2_37_1","volume-title":"Lobachevsky university electrocardiography database. Type: Dataset. Available online: https:\/\/physionet.org\/content\/ludb\/1.0. 0\/(accessed on","author":"Kalyakulina Alena","year":"2021","unstructured":"Alena Kalyakulina, Igor Yusipov, Viktor Moskalenko, Alexander Nikolskiy, Konstantin Kosonogov, Nikolai Zolotykh, and Mikhail Ivanchenko. 2020. Lobachevsky university electrocardiography database. Type: Dataset. Available online: https:\/\/physionet.org\/content\/ludb\/1.0. 0\/(accessed on 10 July 2021) (2020)."},{"key":"e_1_2_2_38_1","volume-title":"The use of wearable ECG devices in the clinical setting: a review. Current emergency and hospital medicine reports 10, 3","author":"Kamga Paola","year":"2022","unstructured":"Paola Kamga, Rasik Mostafa, and Saba Zafar. 2022. The use of wearable ECG devices in the clinical setting: a review. Current emergency and hospital medicine reports 10, 3 (2022), 67\u201372."},{"key":"e_1_2_2_39_1","volume-title":"Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings: a comparison with carefully edited data. Biomedical engineering online 11, 1","author":"Karlsson Marcus","year":"2012","unstructured":"Marcus Karlsson, Rolf H\u00f6rnsten, Annika Rydberg, and Urban Wiklund. 2012. Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings: a comparison with carefully edited data. Biomedical engineering online 11, 1 (2012), 2."},{"key":"e_1_2_2_40_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-024-48682-7"},{"key":"e_1_2_2_41_1","volume-title":"Yong Kyu Lim, and Kwang Suk Park","author":"Kim Ko Keun","year":"2004","unstructured":"Ko Keun Kim, Yong Kyu Lim, and Kwang Suk Park. 2004. The electrically noncontacting ECG measurement on the toilet seat using the capacitively-coupled insulated electrodes. In The 26th annual international conference of the IEEE engineering in medicine and biology society, Vol. 1. IEEE, 2375\u20132378."},{"key":"e_1_2_2_42_1","doi-asserted-by":"crossref","first-page":"3572","DOI":"10.1109\/TBME.2022.3172125","article-title":"Blind ECG restoration by operational cycle-GANs","volume":"69","author":"Kiranyaz Serkan","year":"2022","unstructured":"Serkan Kiranyaz, Ozer Can Devecioglu, Turker Ince, Junaid Malik, Muhammad Chowdhury, Tahir Hamid, Rashid Mazhar, Amith Khandakar, Anas Tahir, Tawsifur Rahman, et al. 2022. Blind ECG restoration by operational cycle-GANs. IEEE Transactions on Biomedical Engineering 69, 12 (2022), 3572\u20133581.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"e_1_2_2_43_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41596-020-00489-8"},{"key":"e_1_2_2_44_1","volume-title":"Graphene electronic tattoos 2.0 with enhanced performance, breathability and robustness. npj 2D Materials and Applications 6, 1","author":"Kireev Dmitry","year":"2022","unstructured":"Dmitry Kireev, Jameson Kampfe, Alena Hall, and Deji Akinwande. 2022. Graphene electronic tattoos 2.0 with enhanced performance, breathability and robustness. npj 2D Materials and Applications 6, 1 (2022), 46."},{"key":"e_1_2_2_45_1","volume-title":"Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos. Nature nanotechnology 17, 8","author":"Kireev Dmitry","year":"2022","unstructured":"Dmitry Kireev, Kaan Sel, Bassem Ibrahim, Neelotpala Kumar, Ali Akbari, Roozbeh Jafari, and Deji Akinwande. 2022. Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos. Nature nanotechnology 17, 8 (2022), 864\u2013870."},{"key":"e_1_2_2_46_1","volume-title":"Computers in cardiology","author":"Laguna Pablo","year":"1997","unstructured":"Pablo Laguna, Roger G Mark, A Goldberg, and George B Moody. 1997. A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG. In Computers in cardiology 1997. IEEE, 673\u2013676."},{"key":"e_1_2_2_47_1","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9781139167970"},{"key":"e_1_2_2_48_1","doi-asserted-by":"crossref","first-page":"3259","DOI":"10.1038\/s41467-025-58390-5","article-title":"Motion-unrestricted dynamic electrocardiogram system utilizing imperceptible electronics","volume":"16","author":"Li Ding","year":"2025","unstructured":"Ding Li, Tian-Rui Cui, Jia-Hao Liu, Wan-Cheng Shao, Xiao Liu, Zhi-Kang Chen, Zi-Gan Xu, Xin Li, Shuo-Yan Xu, Zi-Yi Xie, Jin-Ming Jian, Xu Wang, Lu-Qi Tao, Xiao-Ming Wu, Zhong-Wei Cheng, Zi-Rui Dong, Hou-Fang Liu, Yi Yang, Jun Zhou, and Tian-Ling Ren. 2025. Motion-unrestricted dynamic electrocardiogram system utilizing imperceptible electronics. Nature Communications 16, 1 (2025), 3259.","journal-title":"Nature Communications"},{"key":"e_1_2_2_49_1","volume-title":"TFCDiff: Robust ECG Denoising via Time-Frequency Complementary Diffusion. arXiv preprint arXiv:2511.16627","author":"Li Pengxin","year":"2025","unstructured":"Pengxin Li, Yimin Zhou, Jie Min, Yirong Wang, Wei Liang, and Wang Li. 2025. TFCDiff: Robust ECG Denoising via Time-Frequency Complementary Diffusion. arXiv preprint arXiv:2511.16627 (2025)."},{"key":"e_1_2_2_50_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2006.872823"},{"key":"e_1_2_2_51_1","doi-asserted-by":"crossref","first-page":"5186","DOI":"10.3390\/s25165186","article-title":"Activity Type Effects Signal Quality in Electrocardiogram Devices","volume":"25","author":"Lindsey Bryndan","year":"2025","unstructured":"Bryndan Lindsey, Samantha Snyder, Yuanyuan Zhou, Jae Kun Shim, Jin-Oh Hahn, William Evans, and Joel Martin. 2025. Activity Type Effects Signal Quality in Electrocardiogram Devices. Sensors 25, 16 (2025), 5186.","journal-title":"Sensors"},{"key":"e_1_2_2_52_1","doi-asserted-by":"crossref","unstructured":"Chih-Min Liu Shih-Lin Chang Yung-Hsin Yeh Fa-Po Chung Yu-Feng Hu Chung-Chuan Chou Kuo-Chun Hung Po-Cheng Chang Jo-Nan Liao Yi-Hsin Chan et al. 2021. Enhanced detection of cardiac arrhythmias utilizing 14-day continuous ECG patch monitoring. International journal of cardiology 332 (2021) 78\u201384.","DOI":"10.1016\/j.ijcard.2021.03.015"},{"key":"e_1_2_2_53_1","doi-asserted-by":"publisher","DOI":"10.3390\/s20144009"},{"key":"e_1_2_2_54_1","doi-asserted-by":"publisher","DOI":"10.3390\/bios13010101"},{"key":"e_1_2_2_55_1","volume-title":"Lab-on-skin: a review of flexible and stretchable electronics for wearable health monitoring. ACS nano 11, 10","author":"Liu Yuhao","year":"2017","unstructured":"Yuhao Liu, Matt Pharr, and Giovanni Antonio Salvatore. 2017. Lab-on-skin: a review of flexible and stretchable electronics for wearable health monitoring. ACS nano 11, 10 (2017), 9614\u20139635."},{"key":"e_1_2_2_56_1","volume-title":"Retrieved","author":"L'Oreal Groups","year":"2026","unstructured":"L'Oreal Groups. 2026. L'Oreal Skin Color Scale. Retrieved January, 2026 from https:\/\/www.loreal.com\/en\/articles\/science-and-technology\/expert-inskin\/"},{"key":"e_1_2_2_57_1","volume-title":"Jong-Hyun Ahn, Deji Akinwande, Anne M Andrews, Markus Antonietti, Zhenan Bao, Magnus Berggren, Christopher A Berkey, Christopher John Bettinger, et al.","author":"Luo Yifei","year":"2023","unstructured":"Yifei Luo, Mohammad Reza Abidian, Jong-Hyun Ahn, Deji Akinwande, Anne M Andrews, Markus Antonietti, Zhenan Bao, Magnus Berggren, Christopher A Berkey, Christopher John Bettinger, et al. 2023. Technology roadmap for flexible sensors. ACS nano 17, 6 (2023), 5211\u20135295."},{"key":"e_1_2_2_58_1","volume-title":"NeuroKit2: A Python toolbox for neurophysiological signal processing. Behavior research methods 53, 4","author":"Makowski Dominique","year":"2021","unstructured":"Dominique Makowski, Tam Pham, Zen J Lau, Jan C Brammer, Fran\u00e7ois Lespinasse, Hung Pham, Christopher Sch\u00f6lzel, and SH Annabel Chen. 2021. NeuroKit2: A Python toolbox for neurophysiological signal processing. Behavior research methods 53, 4 (2021), 1689\u20131696."},{"key":"e_1_2_2_59_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2003.821031"},{"key":"e_1_2_2_60_1","volume-title":"Bioimpedance and bioelectricity basics","author":"Martinsen Orjan G","unstructured":"Orjan G Martinsen and Arto Heiskanen. 2023. Bioimpedance and bioelectricity basics. Elsevier."},{"key":"e_1_2_2_61_1","volume-title":"Retrieved","year":"2021","unstructured":"Meta. 2021. Inside Facebook Reality Labs: Wrist-Based Interaction for the Next Computing Platform. Retrieved August, 2025 from https:\/\/about.fb.com\/news\/2021\/03\/inside-facebook-reality-labs-wrist-based-interaction-for-the-next-computing-platform\/"},{"key":"e_1_2_2_62_1","volume-title":"Retrieved","year":"2025","unstructured":"MFIMedical. 2025. Edan SE-2012 12-Channel Holter System. Retrieved August, 2025 from https:\/\/mfimedical.com\/products\/edan-se-2012-12-channel-holter-system?currency=USD&variant=33345791295565&utm_source=google&utm_medium=cpc&utm_campaign=Google%20Shopping&stkn=4c99e12ae1b6&gad_source=1&gad_campaignid=17180879503&gclid=Cj0KCQjw_L_FBhDmARIsAItqgt5ltlzO26zM-Zg2zoxS7gxOTZ4vVOWD-sdQfjINsXnJekVZsbooNy4aAnuEEALw_wcB"},{"key":"e_1_2_2_63_1","volume-title":"Retrieved","year":"2025","unstructured":"MindtecStore. 2025. HeartIn Fit Long-term ECG sportswear T-Shirt Set. Retrieved August, 2025 from https:\/\/www.mindtecstore.com\/HeartIn-Fit-Long-term-ECG-Fitness-T-Shirt-Set-Grey-without-system-unit?srsltid=AfmBOoqpEDwhZyGsBXHN8NLWwya9usK-3sxXH1KtmmOQnFyFohLPLMrx"},{"key":"e_1_2_2_64_1","first-page":"1","article-title":"A flexible capacitive electromyography biomedical sensor for wearable healthcare applications","volume":"72","author":"Ng Charn Loong","year":"2023","unstructured":"Charn Loong Ng, Mamun Bin Ibne Reaz, Maria Liz Crespo, Andres Cicuttin, Mohd Ibrahim Bin Shapiai, Sawal Hamid Bin Md Ali, Noorfazila Binti Kamal, and Muhammad Enamul Hoque Chowdhury. 2023. A flexible capacitive electromyography biomedical sensor for wearable healthcare applications. IEEE Transactions on Instrumentation and Measurement 72 (2023), 1\u201313.","journal-title":"IEEE Transactions on Instrumentation and Measurement"},{"key":"e_1_2_2_65_1","doi-asserted-by":"crossref","first-page":"4174","DOI":"10.3390\/s21124174","article-title":"Wearable smart textiles for long-term electrocardiography monitoring\u2014A review","volume":"21","author":"Nigusse Abreha Bayrau","year":"2021","unstructured":"Abreha Bayrau Nigusse, Desalegn Alemu Mengistie, Benny Malengier, Granch Berhe Tseghai, and Lieva Van Langenhove. 2021. Wearable smart textiles for long-term electrocardiography monitoring\u2014A review. Sensors 21, 12 (2021), 4174.","journal-title":"Sensors"},{"key":"e_1_2_2_66_1","volume-title":"Matthias Georg Schwab, and Kwanpyo Kim","author":"Novoselov Konstantin S","year":"2012","unstructured":"Konstantin S Novoselov, Vladimir I Falko, Luigi Colombo, Pr R Gellert, Matthias Georg Schwab, and Kwanpyo Kim. 2012. A roadmap for graphene. nature 490, 7419 (2012), 192\u2013200."},{"key":"e_1_2_2_67_1","volume-title":"Retrieved","author":"U.S. Bureau of Labor Statistics.","year":"2024","unstructured":"U.S. Bureau of Labor Statistics. 2024. Average hours per day spent in selected activities by age. Retrieved August, 2025 from https:\/\/www.bls.gov\/charts\/american-time-use\/activity-by-age.htm?"},{"key":"e_1_2_2_68_1","volume-title":"Comprehensive Signal Quality Evaluation of a Wearable Textile ECG Garment: A Sex-Balanced Study. arXiv preprint arXiv:2508.21554","author":"Oppelt Maximilian P","year":"2025","unstructured":"Maximilian P Oppelt, Tobias S Zech, Sarah H Lorenz, Laurenz Ottmann, Jan Steffan, Bjoern M Eskofier, Nadine R Lang-Richter, and Norman Pfeiffer. 2025. Comprehensive Signal Quality Evaluation of a Wearable Textile ECG Garment: A Sex-Balanced Study. arXiv preprint arXiv:2508.21554 (2025)."},{"key":"e_1_2_2_69_1","volume-title":"Retrieved","author":"Otter.ai Inc.","year":"2026","unstructured":"Otter.ai Inc. 2026. Otter AI. Retrieved January, 2026 from https:\/\/otter.ai\/"},{"key":"e_1_2_2_70_1","volume-title":"Retrieved","author":"Ltd OYMotion Technologies Co.","year":"2024","unstructured":"Ltd OYMotion Technologies Co. 2024. gForcePro+ EMG Armband. Retrieved August, 2025 from https:\/\/www.oymotion.com\/en\/product32\/149"},{"key":"e_1_2_2_71_1","doi-asserted-by":"publisher","DOI":"10.1145\/3411843"},{"key":"e_1_2_2_72_1","first-page":"815","article-title":"Recommendations for measurement standards in quantitative electrocardiography","volume":"6","author":"Working Party CSE","year":"1985","unstructured":"CSE Working Party. 1985. Recommendations for measurement standards in quantitative electrocardiography. European Heart Journal 6, 10 (1985), 815\u2013825.","journal-title":"European Heart Journal"},{"key":"e_1_2_2_73_1","volume-title":"Proceedings of the International Conference of the IEEE Engineering in Medicine and Biology Society. 1806\u20131809","author":"Penders Julien","unstructured":"Julien Penders, Jef van de Molengraft, Marco Altini, Firat Yazicioglu, and Chris Van Hoof. 2011. A low-power wireless ECG necklace for reliable cardiac activity monitoring on-the-move. In Proceedings of the International Conference of the IEEE Engineering in Medicine and Biology Society. 1806\u20131809."},{"key":"e_1_2_2_74_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1901183"},{"key":"e_1_2_2_75_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.colsurfb.2013.05.022"},{"key":"e_1_2_2_76_1","doi-asserted-by":"crossref","first-page":"04036","DOI":"10.7189\/jogh.12.04036","article-title":"Success and time implications of SpO2 measurement through pulse oximetry among hospitalised children in rural Bangladesh: variability by various device-, provider-and patient-related factors","volume":"12","author":"Rahman Ahmed Ehsanur","year":"2022","unstructured":"Ahmed Ehsanur Rahman, Shafiqul Ameen, Aniqa Tasnim Hossain, Sabrina Jabeen, Tamanna Majid, Azim Uddin Afm, Tania Sultana Tanwi, Goutom Banik, Md Ziaul Haque Shaikh, Md Jahurul Islam, et al. 2022. Success and time implications of SpO2 measurement through pulse oximetry among hospitalised children in rural Bangladesh: variability by various device-, provider-and patient-related factors. Journal of Global Health 12 (2022), 04036.","journal-title":"Journal of Global Health"},{"key":"e_1_2_2_77_1","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1109\/JSEN.2019.2944847","article-title":"A mini review of microneedle array electrode for bio-signal recording: A review","volume":"20","author":"Ren Lei","year":"2019","unstructured":"Lei Ren, Bin Liu, Wei Zhou, and Lelun Jiang. 2019. A mini review of microneedle array electrode for bio-signal recording: A review. IEEE Sensors Journal 20, 2 (2019), 577\u2013590.","journal-title":"IEEE Sensors Journal"},{"key":"e_1_2_2_78_1","volume-title":"Retrieved","author":"Champseix Robin","year":"2026","unstructured":"Robin Champseix. 2026. Heart Rate Variability analysis. Retrieved January, 2026 from https:\/\/github.com\/Aura-healthcare\/hrv-analysis"},{"key":"e_1_2_2_79_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2021.102992"},{"key":"e_1_2_2_80_1","volume-title":"A comparison of manual electrocardiographic interval and waveform analysis in lead 1 of 12-lead ECG and Apple Watch ECG: a validation study. Cardiovascular digital health journal 1, 1","author":"Saghir Nabeel","year":"2020","unstructured":"Nabeel Saghir, Arjun Aggarwal, Nisha Soneji, Victoria Valencia, George Rodgers, and Thomas Kurian. 2020. A comparison of manual electrocardiographic interval and waveform analysis in lead 1 of 12-lead ECG and Apple Watch ECG: a validation study. Cardiovascular digital health journal 1, 1 (2020), 30\u201336."},{"key":"e_1_2_2_81_1","volume-title":"An overview of heart rate variability metrics and norms. Frontiers in public health 5","author":"Shaffer Fred","year":"2017","unstructured":"Fred Shaffer and Jay P Ginsberg. 2017. An overview of heart rate variability metrics and norms. Frontiers in public health 5 (2017), 258."},{"key":"e_1_2_2_82_1","volume-title":"Retrieved","year":"2025","unstructured":"Solventum. 2025. 3M Red Dot Repositionable Monitoring Electrode, 2600 Series. Retrieved August, 2025 from https:\/\/www.solventum.com\/en-us\/home\/f\/b00037639\/"},{"key":"e_1_2_2_83_1","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1038\/s41746-022-00719-1","article-title":"Longitudinal cardio-respiratory fitness prediction through wearables in free-living environments","volume":"5","author":"Spathis Dimitris","year":"2022","unstructured":"Dimitris Spathis, Ignacio Perez-Pozuelo, Tomas I Gonzales, Yu Wu, Soren Brage, Nicholas Wareham, and Cecilia Mascolo. 2022. Longitudinal cardio-respiratory fitness prediction through wearables in free-living environments. NPJ Digital Medicine 5, 1 (2022), 176.","journal-title":"NPJ Digital Medicine"},{"key":"e_1_2_2_84_1","volume-title":"Retrieved","author":"Materials Syscom Advanced","year":"2023","unstructured":"Syscom Advanced Materials. 2023. Liberator Conductive Fibers. Retrieved January, 2026 from https:\/\/metalcladfibers.com\/products\/liberator-conductive-fiber\/"},{"key":"e_1_2_2_85_1","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1016\/j.snb.2017.01.052","article-title":"A microneedle electrode array on flexible substrate for long-term EEG monitoring","volume":"244","author":"Wang Renxin","year":"2017","unstructured":"Renxin Wang, Xiaoming Jiang, Wei Wang, and Zhihong Li. 2017. A microneedle electrode array on flexible substrate for long-term EEG monitoring. Sensors and Actuators B: Chemical 244 (2017), 750\u2013758.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"e_1_2_2_86_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3569503","article-title":"ECG-grained cardiac monitoring using uwb signals","volume":"6","author":"Wang Zhi","year":"2023","unstructured":"Zhi Wang, Beihong Jin, Siheng Li, Fusang Zhang, and Wenbo Zhang. 2023. ECG-grained cardiac monitoring using uwb signals. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies 6, 4 (2023), 1\u201325.","journal-title":"Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"},{"key":"e_1_2_2_87_1","volume-title":"Retrieved","author":"MD","year":"2024","unstructured":"WebMD LLC. 2024. Normal Electrocardiography Intervals. Retrieved January, 2026 from https:\/\/emedicine.medscape.com\/article\/2172196-overview?form=fpf"},{"key":"e_1_2_2_88_1","volume-title":"Medical instrumentation: application and design","author":"Webster John G","unstructured":"John G Webster. 2020. Medical instrumentation: application and design, 5th edition. John Wiley & Sons.","edition":"5"},{"key":"e_1_2_2_89_1","doi-asserted-by":"publisher","DOI":"10.1145\/3706598.3713742"},{"key":"e_1_2_2_90_1","volume-title":"ECG signal reconstruction via Doppler sensor by hybrid deep learning model with CNN and LSTM","author":"Yamamoto Kohei","year":"2020","unstructured":"Kohei Yamamoto, Ryosuke Hiromatsu, and Tomoaki Ohtsuki. 2020. ECG signal reconstruction via Doppler sensor by hybrid deep learning model with CNN and LSTM. IEEE access 8 (2020), 130551\u2013130560."},{"key":"e_1_2_2_91_1","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1016\/j.compscitech.2012.05.005","article-title":"The mechanics of graphene nanocomposites: A review","volume":"72","author":"Young Robert J","year":"2012","unstructured":"Robert J Young, Ian A Kinloch, Lei Gong, and Kostya S Novoselov. 2012. The mechanics of graphene nanocomposites: A review. Composites Science and Technology 72, 12 (2012), 1459\u20131476.","journal-title":"Composites Science and Technology"},{"key":"e_1_2_2_92_1","doi-asserted-by":"crossref","unstructured":"Qinai Zhao Ekaterina Gribkova Yiyang Shen Jilai Cui Noel Naughton Liangshu Liu Jaemin Seo Baixin Tong Mattia Gazzola Rhanor Gillette et al. 2024. Highly stretchable and customizable microneedle electrode arrays for intramuscular electromyography. Science Advances 10 18 (2024) eadn7202.","DOI":"10.1126\/sciadv.adn7202"}],"container-title":["Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.acm.org\/doi\/pdf\/10.1145\/3832035","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T16:35:07Z","timestamp":1790786107000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.acm.org\/doi\/10.1145\/3832035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":92,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9,30]]}},"alternative-id":["10.1145\/3832035"],"URL":"https:\/\/doi.org\/10.1145\/3832035","relation":{},"ISSN":["2474-9567"],"issn-type":[{"value":"2474-9567","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]},"assertion":[{"value":"2026-09-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}