{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,21]],"date-time":"2025-12-21T17:05:27Z","timestamp":1766336727014},"reference-count":15,"publisher":"American Physiological Society","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Applied Physiology"],"published-print":{"date-parts":[[1997,2,1]]},"abstract":"<jats:p> Omboni, Stefano, Gianfranco Parati, Antonella Groppelli, Luisa Ulian, and Giuseppe Mancia. Performance of the AM-5600 blood pressure monitor: comparison with ambulatory intra-arterial pressure. J. Appl. Physiol. 82(2): 698\u2013703, 1997.\u2014The AM-5600 is a new device that simultaneously monitors electrocardiogram (ECG) and noninvasive blood pressure (BP) over a 24-h period. BP readings (Korotkoff sounds and cuff air pressure) are stored into the recorder, allowing the removal of BP artifacts after a visual check. In 12 subjects with essential hypertension, we compared BP values simultaneously provided by the AM-5600 and intra-arterial recordings. At rest, noninvasive systolic BP (SBP) values were lower (5.4 \u00b1 4.9 mmHg) and diastolic BP (DBP) values were higher (7.3 \u00b1 7.3 mmHg) than were intra-arterial values. In ambulatory conditions (9 subjects), between-method discrepancies were +0.8 \u00b1 6.1 and +12.2 \u00b1 7.4 mmHg for 24-h SBP and DBP, respectively. AM-5600 underestimated 24-h intra-arterial SBP and DBP SD, but it accurately tracked intra-arterial SBP and DBP changes. Editing removed 22.1% of total readings, slightly reducing between-method discrepancies. Thus the AM-5600 provides an accurate average estimate of resting and ambulatory SBP and, for DBP, a less accurate estimate that is slightly improved by editing. The AM-5600 allows accurate description of SBP and DBP profiles and thus may be suitable to describe the abrupt BP changes accompanying a number of clinical events. <\/jats:p>","DOI":"10.1152\/jappl.1997.82.2.698","type":"journal-article","created":{"date-parts":[[2017,12,22]],"date-time":"2017-12-22T02:53:49Z","timestamp":1513911229000},"page":"698-703","source":"Crossref","is-referenced-by-count":6,"title":["Performance of the AM-5600 blood pressure monitor: comparison with ambulatory intra-arterial pressure"],"prefix":"10.1152","volume":"82","author":[{"given":"Stefano","family":"Omboni","sequence":"first","affiliation":[{"name":"Istituto Scientifico Ospedale S. Luca, Centro Auxologico Italiano, 20149 Milan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianfranco","family":"Parati","sequence":"additional","affiliation":[{"name":"Istituto Scientifico Ospedale S. Luca, Centro Auxologico Italiano, 20149 Milan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonella","family":"Groppelli","sequence":"additional","affiliation":[{"name":"Istituto Scientifico Ospedale S. Luca, Centro Auxologico Italiano, 20149 Milan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luisa","family":"Ulian","sequence":"additional","affiliation":[{"name":"Cattedra di Medicina Interna, Ospedale S. Gerardo, Monza, Universit\u00e1 degli Studi di Milano,  and Centro di Fisiologia Clinica e Ipertensione, Ospedale Maggiore di Milano, 20122 Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Mancia","sequence":"additional","affiliation":[{"name":"Cattedra di Medicina Interna, Ospedale S. Gerardo, Monza, Universit\u00e1 degli Studi di Milano,  and Centro di Fisiologia Clinica e Ipertensione, Ospedale Maggiore di Milano, 20122 Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"24","reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(97)89369-1"},{"key":"B3","first-page":"329","volume":"36","author":"Bevan A. T.","year":"1969","journal-title":"Clin. Sci."},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-198810000-00006"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.50.1.85"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.5.2.264"},{"key":"B9","first-page":"383","volume":"38","author":"Germano G.","year":"1993","journal-title":"Cardiologia"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960090707"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.20.2.227"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-199306000-00002"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-199306000-00013"},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-199007000-00004"},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)91109-U"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-199007000-00001"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.21.4.504"}],"container-title":["Journal of Applied Physiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.physiology.org\/doi\/pdf\/10.1152\/jappl.1997.82.2.698","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,8]],"date-time":"2019-09-08T13:30:09Z","timestamp":1567949409000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.physiology.org\/doi\/10.1152\/jappl.1997.82.2.698"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,2,1]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1997,2,1]]}},"alternative-id":["10.1152\/jappl.1997.82.2.698"],"URL":"https:\/\/doi.org\/10.1152\/jappl.1997.82.2.698","relation":{},"ISSN":["8750-7587","1522-1601"],"issn-type":[{"value":"8750-7587","type":"print"},{"value":"1522-1601","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,2,1]]}}}