{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T06:15:18Z","timestamp":1792131318143,"version":"4.4.0"},"reference-count":51,"publisher":"American Physiological Society","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Applied Physiology"],"published-print":{"date-parts":[[2008,6]]},"abstract":"<jats:p> The resonant Raman enhancement of hemoglobin (Hb) in the Q band region allows simultaneous identification of oxy- and deoxy-Hb. The heme vibrational bands are well known at 532 nm, but the technique has never been used to determine microvascular Hb oxygen saturation (So<jats:sub>2<\/jats:sub>) in vivo. We implemented a system for in vivo noninvasive measurements of So<jats:sub>2<\/jats:sub>. A laser light was focused onto areas of 15\u201330 \u03bcm in diameter. Using a microscope coupled to a spectrometer and a cooled detector, Raman spectra were obtained in backscattering geometry. Calibration was performed in vitro using blood at several Hb concentrations, equilibrated at various oxygen tensions. So<jats:sub>2<\/jats:sub> was estimated by measuring the intensity of Raman signals (peaks) in the 1,355- to 1,380-cm<jats:sup>\u22121<\/jats:sup> range (oxidation state marker band \u03bd<jats:sub>4<\/jats:sub>), as well as from the \u03bd<jats:sub>19<\/jats:sub> and \u03bd<jats:sub>10<\/jats:sub> bands (1,500- to 1,650-cm<jats:sup>\u22121<\/jats:sup> range). In vivo observations were made in microvessels of anesthetized rats. Glass capillary pathlength and Hb concentration did not affect So<jats:sub>2<\/jats:sub> estimations from Raman spectra. The Hb Raman peaks observed in blood were consistent with earlier Raman studies using Hb solutions and isolated cells. The correlation between Raman-based So<jats:sub>2<\/jats:sub> estimations and So<jats:sub>2<\/jats:sub> measured by CO-oximetry was highly significant for \u03bd<jats:sub>4<\/jats:sub>, \u03bd<jats:sub>10<\/jats:sub>, and \u03bd<jats:sub>19<\/jats:sub> bands. The method allowed So<jats:sub>2<\/jats:sub> determinations in all microvessel types, while diameter and erythrocyte velocity could be measured in the same vessels. Raman microspectroscopy has advantages over other techniques by providing noninvasive and reliable in vivo So<jats:sub>2<\/jats:sub> determinations in thin tissues, as well as in solid organs and tissues in which transillumination is not possible. <\/jats:p>","DOI":"10.1152\/japplphysiol.00025.2008","type":"journal-article","created":{"date-parts":[[2008,3,27]],"date-time":"2008-03-27T21:27:46Z","timestamp":1206653266000},"page":"1809-1817","source":"Crossref","is-referenced-by-count":79,"title":["Measurement of hemoglobin oxygen saturation using Raman microspectroscopy and 532-nm excitation"],"prefix":"10.1152","volume":"104","author":[{"given":"Ivo P.","family":"Torres Filho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Terner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland N.","family":"Pittman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Proffitt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin R.","family":"Ward","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"24","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1016\/0076-6879(81)76132-9"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1016\/0026-2862(84)90047-5"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2836(72)90169-6"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1016\/0005-2795(73)90004-4"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.3109\/10731199009117297"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1366\/0003702953965687"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1046\/j.1523-1747.2001.01258.x"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1520-6343(1998)4:5+<S31::AID-BSPY4>3.0.CO;2-M"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.98.2.479"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1016\/0026-2862(87)90055-0"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1990.258.4.H1216"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1986.251.4.H869"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1987.252.5.H1031"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1016\/0026-2862(88)90089-1"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1007\/PL00011360"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.001172"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2133.2001.04416.x"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1016\/S0026-2862(03)00061-X"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1016\/0026-2862(73)90055-1"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1046\/j.1523-1747.2000.00060.x"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1074\/jbc.M200691200"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1117\/1.1559726"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1366\/000370206777886955"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/S1386-1425(00)00384-X"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1366\/0003702991947874"},{"key":"R26","unstructured":"Pittman RN. Microvessel blood oxygen measurement techniques. In: Microcirculatory Technology, edited by Baker CH and Nastuk WL. New York: Academic, 1986, p. 367\u2013389."},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Pittman RN, Duling BR. Measurement of percent oxyhemoglobin in the microvasculature. J Appl Physiol 38: 371\u2013388, 1975.","DOI":"10.1152\/jappl.1975.38.2.321"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1975.38.2.315"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1038\/347301a0"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1039\/b706997a"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1117\/1.1559730"},{"key":"R32","doi-asserted-by":"publisher","DOI":"10.1117\/1.1689336"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1117\/1.1380668"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1016\/S0076-6879(78)54018-4"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1021\/ar50082a004"},{"key":"R36","unstructured":"Spiro TG, Li XY. Resonance Raman spectroscopy of metalloporphyrins. In: Biological Applications of Raman Spectroscopy, edited by Spiro TG. New York: Wiley, 1988, p. 1\u201338."},{"key":"R37","doi-asserted-by":"publisher","DOI":"10.1021\/ja00809a004"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.1016\/0005-2795(72)90072-4"},{"key":"R39","doi-asserted-by":"publisher","DOI":"10.1021\/j100395a001"},{"key":"R40","doi-asserted-by":"publisher","DOI":"10.1097\/00024382-200115050-00004"},{"key":"R41","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1993.265.4.H1434"},{"key":"R42","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.01171.2004"},{"key":"R43","doi-asserted-by":"publisher","DOI":"10.1590\/S0100-879X2001000100017"},{"key":"R44","doi-asserted-by":"publisher","DOI":"10.1016\/0003-2697(75)90563-1"},{"key":"R45","doi-asserted-by":"publisher","DOI":"10.1016\/0076-6879(93)26016-3"},{"key":"R46","doi-asserted-by":"publisher","DOI":"10.1021\/ac061072x"},{"key":"R47","doi-asserted-by":"publisher","DOI":"10.1097\/01.CCM.0000201898.43135.3F"},{"key":"R48","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-006-0881-8"},{"key":"R49","doi-asserted-by":"publisher","DOI":"10.1002\/bip.10120"},{"key":"R50","doi-asserted-by":"publisher","DOI":"10.1002\/jrs.870"},{"key":"R51","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-4889(01)00089-1"}],"container-title":["Journal of Applied Physiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.physiology.org\/doi\/pdf\/10.1152\/japplphysiol.00025.2008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,8]],"date-time":"2019-09-08T18:06:20Z","timestamp":1567965980000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.physiology.org\/doi\/10.1152\/japplphysiol.00025.2008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,6]]},"references-count":51,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2008,6]]}},"alternative-id":["10.1152\/japplphysiol.00025.2008"],"URL":"https:\/\/doi.org\/10.1152\/japplphysiol.00025.2008","relation":{},"ISSN":["8750-7587","1522-1601"],"issn-type":[{"value":"8750-7587","type":"print"},{"value":"1522-1601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,6]]}}}