{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T15:09:13Z","timestamp":1791212953758,"version":"4.1.0"},"reference-count":36,"publisher":"American Physiological Society","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Applied Physiology"],"published-print":{"date-parts":[[2004,5]]},"abstract":"<jats:p> Patients with obstructive lung disease are exposed to expiratory loads (ELs) and dynamic hyperinflation as a consequence of expiratory flow limitation. To understand how these alterations in lung mechanics might affect cardiac function, we examined the influence of a 10-cmH<jats:sub>2<\/jats:sub>O EL, alone and in combination with voluntary hyperinflation (ELH), on pulmonary pressures [esophageal (Pes) and gastric (Pg)] and cardiac output (CO) in seven healthy subjects. CO was determined by using an acetylene method at rest and at 40 and 70% of peak work. At rest and during exercise, EL resulted in an increase in Pes and Pg (7-18 cmH<jats:sub>2<\/jats:sub>O; P &lt; 0.05) and a decrease in CO (from 5.3 \u00b1 1.8 to 4.5 \u00b1 1.4, 12.2 \u00b1 2.2 to 11.2 \u00b1 2.2, and 16.3 \u00b1 3.3 to 15.2 \u00b1 3.2 l\/min for rest, 40% peak work, and 70% peak work, respectively; P &lt; 0.05), which remained depressed after an additional 2 min of EL. With ELH, CO increased at rest and both exercise loads (relative to EL only) but remained below control values. The changes in CO were due to a reduction in stroke volume with a tendency for stroke volume to fall further with prolonged EL. There was a negative correlation between CO and the increase in expiratory Pes and Pg with EL ( R = -0.58 and -0.60; P &lt; 0.01), whereas the rise in CO with subsequent hyperinflation was related to a more negative Pes ( R = 0.72; P &lt; 0.01). In conclusion, EL leads to a reduction in CO, which appears to be primarily related to increases in expiratory abdominal and intrathoracic pressure, whereas ELH resulted in an improved CO, suggesting that lung inflation has little impact on cardiac function. <\/jats:p>","DOI":"10.1152\/japplphysiol.00756.2003","type":"journal-article","created":{"date-parts":[[2004,4,9]],"date-time":"2004-04-09T00:57:57Z","timestamp":1081472277000},"page":"1920-1927","source":"Crossref","is-referenced-by-count":96,"title":["Influence of expiratory loading and hyperinflation on cardiac output during exercise"],"prefix":"10.1152","volume":"96","author":[{"given":"Kristy N.","family":"Stark-Leyva","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken C.","family":"Beck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce D.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"24","reference":[{"key":"REF1","doi-asserted-by":"publisher","DOI":"10.5271\/sjweh.2389"},{"key":"REF2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.163.5.9908025"},{"key":"REF3","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1999.86.4.1388"},{"key":"REF4","doi-asserted-by":"crossref","unstructured":"Belman MJ. Factors limiting exercise performance in lung disease. Ventilatory insufficiency. Chest 101, Suppl 5: 253S-254S, 1992.","DOI":"10.1378\/chest.101.5.253S"},{"key":"REF5","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-1716.1979.tb06332.x"},{"key":"REF6","unstructured":"Cassidy SS and Mitchell JH. Effects of positive pressure breathing on right and left ventricular preload and afterload. Fed Proc 40: 2178-2181, 1981."},{"key":"REF7","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1978.44.5.743"},{"key":"REF8","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197102000-00012"},{"key":"atypb1","unstructured":"Cook TI, Trimble FC, Welch WC, Rehman I, and Trummer MJ. A comparative study of pulmonary and circulatory effects of extrathoracic assisted breathing and intermittent positive pressure breathing. Int Surg 56: 63-67, 1971."},{"key":"REF10","doi-asserted-by":"publisher","DOI":"10.1007\/BF02044117"},{"key":"REF11","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1021029"},{"key":"REF12","doi-asserted-by":"publisher","DOI":"10.1007\/BF01694770"},{"key":"REF13","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1975.39.5.697"},{"key":"REF14","unstructured":"Goodman LS, Fraser WD, Eastman DE, and Ackles KN. Cardiovascular responses to positive pressure breathing using the tactical life support system. Aviat Space Environ Med 63: 662-669, 1992."},{"key":"REF15","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/137.1.132"},{"key":"REF16","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1993.sp019483"},{"key":"REF17","unstructured":"Janicki JS, Sheriff DD, Robotham JL, and Wise RA. Cardiac output during exercise: contributions of the cardiac, circulatory, and respiratory systems. In: Handbook of Physiology. Exercise: Regulation and Integration of Multiple Systems. Bethesda, MD: Am. Physiol. Soc. 1996, sect. 12, chapt. 15, p. 649-704."},{"key":"REF18","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1993.sp019477"},{"key":"REF19","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2000.88.5.1650"},{"key":"REF20","unstructured":"Lamy M, Deghislage J, Lamalle D, and Hanquet M. Hemodynamic effects of intermittent or continuous positive-pressure breathing in man. Acta Anaesthesiol Belg 24: 270-287, 1973."},{"key":"REF21","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00394.2001"},{"key":"REF22","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.154.5.8912737"},{"key":"REF23","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.158.5.9804004"},{"key":"REF24","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.158.6.9802015"},{"key":"REF25","doi-asserted-by":"publisher","DOI":"10.1172\/JCI106563"},{"key":"REF26","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1978.44.5.703"},{"key":"REF27","unstructured":"Robotham JL and Peters J. Mechanical effects of intrathoracic pressure on ventricualr performance. In: Heart Lung Interactions in Health and Disease, edited by Scharf SM and Cassidy SS. New York: Dekker, 1989, p. 251-283."},{"key":"REF28","unstructured":"Rodarte JR. Stress-strain analysis and the lung. Fed Proc 41: 130-135, 1982."},{"key":"REF29","doi-asserted-by":"publisher","DOI":"10.1007\/BF02714137"},{"key":"REF30","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2001.91.1.269"},{"key":"REF31","doi-asserted-by":"publisher","DOI":"10.1378\/chest.106.4.1182"},{"key":"REF32","doi-asserted-by":"publisher","DOI":"10.1378\/chest.89.2.199"},{"key":"REF33","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1990.69.6.1961"},{"key":"REF34","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1983.54.4.1039"},{"key":"REF35","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1984.57.4.971"},{"key":"REF36","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1982.53.1.280"}],"container-title":["Journal of Applied Physiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.physiology.org\/doi\/pdf\/10.1152\/japplphysiol.00756.2003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,8]],"date-time":"2019-09-08T20:05:15Z","timestamp":1567973115000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.physiology.org\/doi\/10.1152\/japplphysiol.00756.2003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,5]]},"references-count":36,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2004,5]]}},"alternative-id":["10.1152\/japplphysiol.00756.2003"],"URL":"https:\/\/doi.org\/10.1152\/japplphysiol.00756.2003","relation":{},"ISSN":["8750-7587","1522-1601"],"issn-type":[{"value":"8750-7587","type":"print"},{"value":"1522-1601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,5]]}}}