{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T10:30:22Z","timestamp":1776335422171,"version":"3.51.2"},"reference-count":30,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,7,20]],"date-time":"2008-07-20T00:00:00Z","timestamp":1216512000000},"content-version":"vor","delay-in-days":201,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/501100001407","name":"Department of Biotechnology , Ministry of Science and Technology","doi-asserted-by":"publisher","award":["BT\/PR6440\/ MED\/14\/812\/2005"],"award-info":[{"award-number":["BT\/PR6440\/ MED\/14\/812\/2005"]}],"id":[{"id":"10.13039\/501100001407","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Sensors"],"published-print":{"date-parts":[[2008,1]]},"abstract":"<jats:p>A reliable, fast, and low\u2010cost biosensor for medical diagnostics using \n                  DNA sequence detection has been developed and tested for the detection \n                  of the bacterium \u201c<jats:italic>Bacillus anthracis<\/jats:italic>.\u201d In this sensor, Poly [9,9\u2010di (6,6<jats:sup>\u2032<\/jats:sup>\u2010 N, N<jats:sup>\u2032<\/jats:sup> trimethylammonium) hexylfluorenyl\u20102, 7\u2010diyl)\u2010alt\u2010co\u2010 (1,4\u2010phenylene)] \n  dibromide salt (PFP) has been taken as cationic conjugated polymer (CCP) and PNA \n  attached with fluorescein dye (PNAC<jats:sup>\u2217<\/jats:sup>) as a probe. The basic principle of this sensor is that when a PNAC<jats:sup>\u2217<\/jats:sup> probe is hybridized with a single strand DNA (ssDNA) having \n  complementary sequence, Forster resonance energy transfer (FRET) may take place from PFP to the PNAC<jats:sup>\u2217<\/jats:sup>\/DNA complex. If the FRET is efficient, the photoluminescence from the PFP will be highly quenched and that from PNAC<jats:sup>\u2217<\/jats:sup> will be enhanced. On the other hand, if the DNA sequence is noncomplementary to PNA, FRET will not occur.<\/jats:p>","DOI":"10.1155\/2008\/270475","type":"journal-article","created":{"date-parts":[[2008,7,22]],"date-time":"2008-07-22T12:45:27Z","timestamp":1216730727000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A New FRET\u2010Based Sensitive DNA Sensor for Medical Diagnostics using                         PNA Probe and Water\u2010Soluble Blue Light Emitting Polymer"],"prefix":"10.1155","volume":"2008","author":[{"given":"Nidhi","family":"Mathur","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anamika","family":"Aneja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. K.","family":"Bhatnagar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. C.","family":"Mathur","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,7,20]]},"reference":[{"key":"e_1_2_6_1_2","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.bioeng.4.020702.153438"},{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.297.5586.1536"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac034596v"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1021\/ja0279996"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.2364459"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1088\/0957-4484\/17\/12\/009"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1038\/nbt0901-833"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1021\/la0107704"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1633515100"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1038\/82454"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.232276699"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1038\/85704"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1021\/ja010045f"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0076-6879(99)06003-6"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1103\/RevModPhys.73.681"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.96.22.12287"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1021\/ja025899u"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.96.22.12219"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1132025100"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1021\/ar9600502"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1557\/mrs2002.143"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/365566a0"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0958-1669(99)80013-5"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0006-2952(94)90171-6"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-0-387-46312-4"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1389-0352(01)00039-3"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.0408568102"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.162375999"},{"key":"e_1_2_6_29_2","unstructured":"Fluorescent Resonance Energy Transfer (FRET) as a probe of proximity in proteins http:\/\/dwb.unl.edu\/Teacher\/NSF\/C08\/C08Links\/pps99.cryst.bbk.ac.uk\/projects\/gmocz\/fret.htm."},{"key":"e_1_2_6_30_2","unstructured":"BhatnagarP. K. MathurP. C. MathurN. andAnejaA. Low cost portable sensors for medical diagnostics using Forster resonance energy transfer between water soluble cationic conjugated polymers and PNAC\u2217probes Proceedings of the 18th International Conference on Materials for Advanced Technologies (ICMAT \u203207) July 2007 Singapore."}],"container-title":["Journal of Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2008\/270475.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2008\/270475.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2008\/270475","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T12:42:35Z","timestamp":1719924155000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2008\/270475"}},"subtitle":[],"editor":[{"given":"Mike","family":"McShane","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2008,1]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,1]]}},"alternative-id":["10.1155\/2008\/270475"],"URL":"https:\/\/doi.org\/10.1155\/2008\/270475","archive":["Portico"],"relation":{},"ISSN":["1687-725X","1687-7268"],"issn-type":[{"value":"1687-725X","type":"print"},{"value":"1687-7268","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,1]]},"assertion":[{"value":"2008-01-02","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2008-06-03","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2008-07-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"270475"}}