{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T14:33:32Z","timestamp":1753886012129,"version":"3.41.2"},"reference-count":18,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,3,18]],"date-time":"2008-03-18T00:00:00Z","timestamp":1205798400000},"content-version":"vor","delay-in-days":77,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["0635288"],"award-info":[{"award-number":["0635288"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Biomedical Imaging"],"published-print":{"date-parts":[[2008,1]]},"abstract":"<jats:p>The reconstruction of 3D ultrasound (US) images from \n                  mechanically registered, but otherwise irregularly positioned, \n                  B\u2010scan slices is of great interest in image guided therapy procedures. \n                  Conventional 3D ultrasound algorithms have low computational complexity, but the reconstructed volume suffers from severe speckle contamination. Furthermore, the current method cannot reconstruct uniform high\u2010resolution data from several low\u2010resolution B\u2010scans. In this paper, the minimum mean\u2010squared error (MMSE) method is applied to 3D ultrasound reconstruction. Data redundancies due to overlapping samples as well as correlation of the target and speckle are naturally accounted for in the MMSE reconstruction algorithm. Thus, the reconstruction process unifies the interpolation and spatial compounding. Simulation results for synthetic US images are presented to demonstrate the excellent reconstruction.<\/jats:p>","DOI":"10.1155\/2008\/274164","type":"journal-article","created":{"date-parts":[[2008,12,23]],"date-time":"2008-12-23T14:45:49Z","timestamp":1230043549000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["MMSE Reconstruction for 3D Freehand Ultrasound Imaging"],"prefix":"10.1155","volume":"2008","author":[{"given":"Wei","family":"Huang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yibin","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,3,18]]},"reference":[{"volume-title":"Three-Dimensional Ultrasound","year":"1999","author":"Nelson T. R.","key":"e_1_2_7_1_2"},{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1109\/51.544511"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1177\/016173469802000101"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00995508"},{"key":"e_1_2_7_5_2","unstructured":"RohlingR. N. 3D freehand ultrasound: reconstruction and spatial compounding Ph.D. dissertation 1999 University of Cambridge Cambridge UK."},{"key":"e_1_2_7_6_2","doi-asserted-by":"crossref","unstructured":"SherebrinS. FensterA. RankinR. N. andSpenceD. Freehand three-dimensional ultrasound: implementation and applications 2708 Medical Imaging 1996: Physics of Medical Imaging February 1996 Newport Beach Calif USA 296\u2013303 Proceedings of SPIE https:\/\/doi.org\/10.1117\/12.237790.","DOI":"10.1117\/12.237790"},{"key":"e_1_2_7_7_2","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/978-3-642-84211-5_2","volume-title":"3D Imaging in Medicine: Algorithms, Systems, Applications","author":"Hottier F.","year":"1990"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-5629(97)00123-3"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/58.4184"},{"volume-title":"Statistical Signal Processing: Detection, Estimation, and Time Series Analysis","year":"1991","author":"Scharf L. L.","key":"e_1_2_7_10_2"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1109\/MSP.2003.1203207"},{"key":"e_1_2_7_12_2","unstructured":"BormanS.andStevensonR. L. Super-resolution image reconstruction enhancement of low-resolution image sequences: a comprehensive review with directions for future research 1998 JulyLaboratory for Image and Signal Analysis University of Notre Dame Notre Dame Ind USA."},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1006\/jvci.1993.1030"},{"key":"e_1_2_7_14_2","doi-asserted-by":"crossref","unstructured":"TomB. C.andKatsaggelosA. K. Reconstruction of a high resolution image from multiple degraded mis-registered low resolution images 2308 Visual Communications and Image Processing (VCIP \u203294) September 1994 Chicago Ill USA 971\u2013981 Proceedings of SPIE https:\/\/doi.org\/10.1117\/12.186041.","DOI":"10.1117\/12.186041"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.1982.4307555"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.1982.4307556"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.1.000398"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1112\/S0025579300008184"}],"container-title":["International Journal of Biomedical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijbi\/2008\/274164.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijbi\/2008\/274164.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2008\/274164","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,28]],"date-time":"2024-06-28T13:15:01Z","timestamp":1719580501000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2008\/274164"}},"subtitle":[],"editor":[{"given":"Guowei","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2008,1]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,1]]}},"alternative-id":["10.1155\/2008\/274164"],"URL":"https:\/\/doi.org\/10.1155\/2008\/274164","archive":["Portico"],"relation":{},"ISSN":["1687-4188","1687-4196"],"issn-type":[{"type":"print","value":"1687-4188"},{"type":"electronic","value":"1687-4196"}],"subject":[],"published":{"date-parts":[[2008,1]]},"assertion":[{"value":"2007-11-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2008-01-27","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2008-03-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"274164"}}