{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T11:10:04Z","timestamp":1789643404250,"version":"4.0.0"},"reference-count":42,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,9,24]],"date-time":"2008-09-24T00:00:00Z","timestamp":1222214400000},"content-version":"vor","delay-in-days":267,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000024","name":"Canadian Institutes of Health Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000024","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Biomedical Imaging"],"published-print":{"date-parts":[[2008,1]]},"abstract":"<jats:p>\n                    An important aspect of functional magnetic resonance imaging (fMRI) is the study of brain hemodynamics, and MR arterial spin labeling (ASL) perfusion imaging has gained wide acceptance as a robust and noninvasive technique. However, the cerebral blood flow (CBF) measurements obtained with ASL fMRI have not been fully validated, particularly during global CBF modulations. We present a comparison of cerebral blood flow changes (\n                    <jats:italic>\u0394<\/jats:italic>\n                    CBF) measured using a flow\u2010sensitive alternating inversion recovery (FAIR) ASL perfusion method to those obtained using H\n                    <jats:sub>2<\/jats:sub>\n                    <jats:sub>\u2009<\/jats:sub>\n                    <jats:sup>15<\/jats:sup>\n                    O PET, which is the current gold standard for in vivo imaging of CBF. To study regional and global CBF changes, a group of 10 healthy volunteers were imaged under identical experimental conditions during presentation of 5 levels of visual stimulation and one level of hypercapnia. The CBF changes were compared using 3 types of region\u2010of\u2010interest (ROI) masks. FAIR measurements of CBF changes were found to be slightly lower than those measured with PET (average\n                    <jats:italic>\u0394<\/jats:italic>\n                    CBF of 21.5 \u00b1 8.2% for FAIR versus 28.2 \u00b1 12.8% for PET at maximum stimulation intensity). Nonetheless, there was a strong correlation between measurements of the two modalities. Finally, a\n                    <jats:italic>t<\/jats:italic>\n                    \u2010test comparison of the slopes of the linear fits of PET versus ASL\n                    <jats:italic>\u0394<\/jats:italic>\n                    CBF for all 3 ROI types indicated no significant difference from unity (\n                    <jats:italic>P<\/jats:italic>\n                    &gt; .05).\n                  <\/jats:p>","DOI":"10.1155\/2008\/516359","type":"journal-article","created":{"date-parts":[[2008,9,25]],"date-time":"2008-09-25T09:04:33Z","timestamp":1222333473000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":55,"title":["Cerebral Blood Flow Measurement Using fMRI and PET: A Cross\u2010Validation Study"],"prefix":"10.1155","volume":"2008","author":[{"given":"Jean J.","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marguerite","family":"Wieckowska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ernst","family":"Meyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. Bruce","family":"Pike","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,9,24]]},"reference":[{"key":"e_1_2_6_1_2","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1940070112"},{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-199907000-00001"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<849::AID-MRM4>3.0.CO;2-Z"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910390506"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO;2-N"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2006.09.015"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20362"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1006\/nimg.1999.0443"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910310208"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20451"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-199809000-00002"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-200209000-00013"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10021"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2005.02.028"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2594(200009)44:3<450::AID-MRM16>3.0.CO;2-0"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2594(200103)45:3<431::AID-MRM1056>3.0.CO;2-E"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1118\/1.598652"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2004.01.017"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1099-1492(199706\/08)10:4\/5<237::AID-NBM475>3.0.CO;2-X"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910400308"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20843"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2005.05.038"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2005.10.038"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910370321"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.95.4.1834"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1006\/nimg.2001.0916"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1006\/nimg.1999.0496"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.96.16.9403"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-199903000-00005"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1109\/23.106696"},{"key":"e_1_2_6_31_2","doi-asserted-by":"crossref","unstructured":"OllingerJ. M.andJohnsG. C. Model-based scatter correction for fully 3D PET Proceedings of IEEE Nuclear Science Symposium and Medical Imaging Conference October 2006 San Diego Calif USA 1264\u20131268.","DOI":"10.1109\/NSSMIC.1993.701845"},{"key":"e_1_2_6_32_2","first-page":"1056","article-title":"The application of a masked orbiting transmission source for attenuation correction in PET","volume":"30","author":"Ranger N. T.","year":"1989","journal-title":"Journal of Nuclear Medicine"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1109\/23.34613"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004647-199609000-00002"},{"key":"e_1_2_6_35_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.7754376"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1006\/nimg.2001.0933"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/1053-8119(92)90006-9"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1118\/1.597000"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199403000-00005"},{"key":"e_1_2_6_40_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199207000-00024"},{"key":"e_1_2_6_41_2","doi-asserted-by":"publisher","DOI":"10.1006\/nimg.1999.0526"},{"key":"e_1_2_6_42_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20262"}],"container-title":["International Journal of Biomedical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijbi\/2008\/516359.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijbi\/2008\/516359.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2008\/516359","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T21:35:45Z","timestamp":1738359345000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2008\/516359"}},"subtitle":[],"editor":[{"given":"Yantian","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2008,1]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,1]]}},"alternative-id":["10.1155\/2008\/516359"],"URL":"https:\/\/doi.org\/10.1155\/2008\/516359","archive":["Portico"],"relation":{},"ISSN":["1687-4188","1687-4196"],"issn-type":[{"value":"1687-4188","type":"print"},{"value":"1687-4196","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,1]]},"assertion":[{"value":"2008-06-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2008-07-22","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2008-09-24","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"516359"}}