{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T16:33:25Z","timestamp":1757781205301},"reference-count":31,"publisher":"Hindawi Limited","license":[{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computational and Mathematical Methods in Medicine"],"published-print":{"date-parts":[[2012]]},"abstract":"<jats:p>Increasing interest is drawn on hemodynamic parameters for classifying the risk of rupture as well as treatment planning of cerebral aneurysms. A proposed method to obtain quantities such as wall shear stress, pressure, and blood flow velocity is to numerically simulate the blood flow using computational fluid dynamics (CFD) methods. For the validation of those calculated quantities, virtually generated angiograms, based on the CFD results, are increasingly used for a subsequent comparison with real, acquired angiograms. For the generation of virtual angiograms, several patient-specific parameters have to be incorporated to obtain virtual angiograms which match the acquired angiograms as best as possible. For this purpose, a workflow is presented and demonstrated involving multiple phantom and patient cases.<\/jats:p>","DOI":"10.1155\/2012\/306765","type":"journal-article","created":{"date-parts":[[2012,11,4]],"date-time":"2012-11-04T21:00:41Z","timestamp":1352062841000},"page":"1-24","source":"Crossref","is-referenced-by-count":16,"title":["A Workflow for Patient-Individualized Virtual Angiogram Generation Based on CFD Simulation"],"prefix":"10.1155","volume":"2012","author":[{"given":"J\u00fcrgen","family":"Endres","sequence":"first","affiliation":[{"name":"Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander University of Erlangen-Nuremberg, Martensstrasse 3, 91058 Erlangen, Germany"}]},{"given":"Markus","family":"Kowarschik","sequence":"additional","affiliation":[{"name":"Angiography & Interventional X-Ray Systems, Healthcare Sector, Siemens AG, Siemensstrasse 1, 91301 Forchheim, Germany"}]},{"given":"Thomas","family":"Redel","sequence":"additional","affiliation":[{"name":"Angiography & Interventional X-Ray Systems, Healthcare Sector, Siemens AG, Siemensstrasse 1, 91301 Forchheim, Germany"}]},{"given":"Puneet","family":"Sharma","sequence":"additional","affiliation":[{"name":"Corporate Research and Technology, Siemens Corporation, 755 College Road East, Princeton, NJ 08540, USA"}]},{"given":"Viorel","family":"Mihalef","sequence":"additional","affiliation":[{"name":"Corporate Research and Technology, Siemens Corporation, 755 College Road East, Princeton, NJ 08540, USA"}]},{"given":"Joachim","family":"Hornegger","sequence":"additional","affiliation":[{"name":"Pattern Recognition Lab, Department of Computer Science, Friedrich-Alexander University of Erlangen-Nuremberg, Martensstrasse 3, 91058 Erlangen, Germany"},{"name":"Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander University of Erlangen-Nuremberg, 91052 Erlangen, Germany"}]},{"given":"Arnd","family":"D\u00f6rfler","sequence":"additional","affiliation":[{"name":"Department of Neuroradiology, Friedrich-Alexander University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany"}]}],"member":"98","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1093\/bmb\/ldp028"},{"issue":"1","key":"2","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3171\/jns.2002.96.1.0043","volume":"96","year":"2002","journal-title":"Journal of Neurosurgery"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra052760"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199701023360106"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2011.00045"},{"key":"6","year":"2005"},{"key":"7","first-page":"33","volume-title":"3D imaging with flat-detector c-arm systems","year":"2009"},{"issue":"4","key":"9","first-page":"559","volume":"24","year":"2003","journal-title":"American Journal of Neuroradiology"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2005.859204"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1118\/1.3483066"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2005.844159"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2007.03.008"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1118\/1.3675402"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1006\/jcph.1994.1155"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1098\/?rsfs.2010.0036"},{"issue":"2","key":"21","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/0021-9991(89)90151-4","volume":"85","year":"1989","journal-title":"Journal of Computational Physics"},{"issue":"2","key":"22","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1063\/1.870305","volume":"12","year":"2000","journal-title":"Physics of Fluids"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1006\/jcph.2000.6686"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1147\/rd.112.0215"},{"key":"26","series-title":"Texts in Applied Mathematics","year":"2003"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-010-0202-4"},{"key":"28","year":"1999"},{"issue":"3","key":"29","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/0146-664X(80)90054-4","volume":"14","year":"1980","journal-title":"Computer Graphics and Image Processing"},{"key":"31","year":"2000"},{"key":"32","year":"2004"},{"key":"33","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/BFb0056194","volume-title":"3D reconstruction from projection matrices in a c-arm based 3D-angiography system","volume":"1496","year":"1998"},{"key":"35","year":"2006"},{"key":"36","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1177\/15910199110170S126","volume":"17","year":"2011","journal-title":"Interventional Neuroradiology"},{"key":"37","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/50\/13\/014"},{"key":"38","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A0652"},{"key":"39","doi-asserted-by":"publisher","DOI":"10.1118\/1.3243079"}],"container-title":["Computational and Mathematical Methods in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2012\/306765.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2012\/306765.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2012\/306765.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,21]],"date-time":"2017-06-21T02:16:39Z","timestamp":1498011399000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.hindawi.com\/journals\/cmmm\/2012\/306765\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012]]},"references-count":31,"alternative-id":["306765","306765"],"URL":"https:\/\/doi.org\/10.1155\/2012\/306765","relation":{},"ISSN":["1748-670X","1748-6718"],"issn-type":[{"value":"1748-670X","type":"print"},{"value":"1748-6718","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012]]}}}