{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T16:04:58Z","timestamp":1761581098480,"version":"3.37.3"},"reference-count":32,"publisher":"Wiley","license":[{"start":{"date-parts":[[2013,1,1]],"date-time":"2013-01-01T00:00:00Z","timestamp":1356998400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Advances in Fuzzy Systems"],"published-print":{"date-parts":[[2013]]},"abstract":"<jats:p>Dissolved gas analysis (DGA) of transformer oil has been one of the most reliable techniques to detect the incipient faults. Many conventional DGA methods have been developed to interpret DGA results obtained from gas chromatography. Although these methods are widely used in the world, they sometimes fail to diagnose, especially when DGA results fall outside conventional methods codes or when more than one fault exist in the transformer. To overcome these limitations, the fuzzy inference system (FIS) is proposed. Two hundred different cases are used to test the accuracy of various DGA methods in interpreting the transformer condition.<\/jats:p>","DOI":"10.1155\/2013\/421621","type":"journal-article","created":{"date-parts":[[2013,6,18]],"date-time":"2013-06-18T17:01:18Z","timestamp":1371574878000},"page":"1-7","source":"Crossref","is-referenced-by-count":8,"title":["Fuzzy Algorithm for Power Transformer Diagnostics"],"prefix":"10.1155","volume":"2013","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8326-7971","authenticated-orcid":true,"given":"Nitin K.","family":"Dhote","sequence":"first","affiliation":[{"name":"St. Vincent Pallotti College of Engineering and Technology, Wardha Road, Nagpur 441108, India"}]},{"given":"Jagdish B.","family":"Helonde","sequence":"additional","affiliation":[{"name":"Principal ITM College of Engineering, Nagpur, India"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2006.1618968"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2000.879355"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2006.1593420"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2002.1161456"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2006.879708"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2005.856648"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2003.1192031"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2004.1367506"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2011.6025366"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2010.2091325"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2003.1237337"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1109\/57.917529"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2005.1489986"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2002.1014963"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1109\/MEI.2008.4665347"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1109\/61.180341"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1109\/61.584363"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1109\/61.796227"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1109\/61.544265"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1109\/61.956751"},{"issue":"3","key":"26","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1049\/ip-gtd:20040833","volume":"152","year":"2005","journal-title":"IEE Generation Transmission Distribution"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2003.813605"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2008.2002652"},{"key":"29","first-page":"221","volume":"62","year":"2010","journal-title":"World Academy of Science, Engineering and Technology"},{"key":"30","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2005.864044"},{"issue":"5","key":"31","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1109\/MEI.2012.6268440","volume":"28","year":"2012","journal-title":"IEEE Electrical Insulation Magzine"},{"key":"32","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2008.2002974"},{"key":"33","doi-asserted-by":"publisher","DOI":"10.1109\/61.714488"},{"key":"34"},{"key":"35"},{"key":"36"},{"key":"37"}],"container-title":["Advances in Fuzzy Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/afs\/2013\/421621.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/afs\/2013\/421621.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/afs\/2013\/421621.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,21]],"date-time":"2017-06-21T10:51:33Z","timestamp":1498042293000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.hindawi.com\/journals\/afs\/2013\/421621\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":32,"alternative-id":["421621","421621"],"URL":"https:\/\/doi.org\/10.1155\/2013\/421621","relation":{},"ISSN":["1687-7101","1687-711X"],"issn-type":[{"type":"print","value":"1687-7101"},{"type":"electronic","value":"1687-711X"}],"subject":[],"published":{"date-parts":[[2013]]}}}