{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T16:24:38Z","timestamp":1761841478349,"version":"3.37.3"},"reference-count":41,"publisher":"Wiley","license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/501100004837","name":"Ministerio de Ciencia e Innovaci\u00f3n, Spain","doi-asserted-by":"crossref","award":["FIS2011-22496","FPUZ-2011-BIO-02"],"award-info":[{"award-number":["FIS2011-22496","FPUZ-2011-BIO-02"]}],"id":[{"id":"10.13039\/501100004837","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Zaragoza University","award":["FIS2011-22496","FPUZ-2011-BIO-02"],"award-info":[{"award-number":["FIS2011-22496","FPUZ-2011-BIO-02"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BioMed Research International"],"published-print":{"date-parts":[[2014]]},"abstract":"<jats:p><jats:italic>Purpose<\/jats:italic>. To assess the normal values and the repeatability of the Galilei Dual Scheimpflug Analyzer (GDSA), the biometer IOL Master, and the autokerato\/refractometer WAM 5500 in anterior segment examinations.<jats:italic>Methods<\/jats:italic>. Eighty-eight eyes from 88 healthy volunteers were prospectively and consecutively recruited. The repeatability was assessed, calculating the intraclass correlation coefficient (ICC).<jats:italic>Results<\/jats:italic>. The correlations among the repeated measurements showed nearly perfect reliability (ICC &gt; 0.81) for all of the parameters, except corneal astigmatism Galilei (0.79) and WAM (0.68). There were statistically significant differences (<mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M1\"><mml:mi>P<\/mml:mi><mml:mo>&lt;<\/mml:mo><mml:mn>0.001<\/mml:mn><\/mml:math>) between the values of the flat simulated keratometry (SimK) and the steep SimK measured by GDSA and the other methods; however, there were no statistically significant differences for the values obtained with the IOL Master and WAM 5500 (<mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M2\"><mml:mi>P<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>0.302<\/mml:mn><\/mml:math>and<mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M3\"><mml:mi>P<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>0.172<\/mml:mn><\/mml:math>, resp.) or between the values of the ACD (<mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M4\"><mml:mi>P<\/mml:mi><mml:mo>&lt;<\/mml:mo><mml:mn>0.001<\/mml:mn><\/mml:math>) and WTW (<mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M5\"><mml:mi>P<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>0.007<\/mml:mn><\/mml:math>) measured by the IOL Master and GDSA.<jats:italic>Conclusions<\/jats:italic>. The anterior segment measurements from the IOL Master and WAM 5500 were highly repeatable, comparable, and well correlated. In healthy young persons, the evaluated parameters had very good repeatability, although significant differences were found between the GDSA and IOL Master and between the GDSA and WAM 5500.<\/jats:p>","DOI":"10.1155\/2014\/498080","type":"journal-article","created":{"date-parts":[[2014,6,2]],"date-time":"2014-06-02T18:50:43Z","timestamp":1401735043000},"page":"1-8","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Anterior Segment Measurements Obtained by Three Different Devices in Healthy Eyes"],"prefix":"10.1155","volume":"2014","author":[{"given":"Carmen","family":"Lopez de la Fuente","sequence":"first","affiliation":[{"name":"Department of Applied Physics, University of Zaragoza, C\/Pedro Cerbuna 12, 50009 Zaragoza, Spain"},{"name":"Aragon Health Sciences Institute, Avenida San Juan Bosco 13, 50009 Zaragoza, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana","family":"Sanchez-Cano","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, University of Zaragoza, C\/Pedro Cerbuna 12, 50009 Zaragoza, Spain"},{"name":"Aragon Health Sciences Institute, Avenida San Juan Bosco 13, 50009 Zaragoza, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9250-9060","authenticated-orcid":true,"given":"Francisco","family":"Segura","sequence":"additional","affiliation":[{"name":"Aragon Health Sciences Institute, Avenida San Juan Bosco 13, 50009 Zaragoza, Spain"},{"name":"Department of Surgery, Gynecology and Obstetrics, University of Zaragoza, C\/Pedro Cerbuna 12, 50009 Zaragoza, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0349-9997","authenticated-orcid":true,"given":"Isabel","family":"Pinilla","sequence":"additional","affiliation":[{"name":"Aragon Health Sciences Institute, Avenida San Juan Bosco 13, 50009 Zaragoza, Spain"},{"name":"Department of Surgery, Gynecology and Obstetrics, University of Zaragoza, C\/Pedro Cerbuna 12, 50009 Zaragoza, Spain"},{"name":"Department of Ophthalmology, Lozano Blesa University Hospital, Avenida San Juan Bosco 15, 50009 Zaragoza, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"issue":"4","key":"1","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1111\/j.1444-0938.2012.00761.x","volume":"95","year":"2012","journal-title":"Clinical and Experimental Optometry"},{"doi-asserted-by":"publisher","key":"2","DOI":"10.3928\/1081597X-20101215-07"},{"doi-asserted-by":"publisher","key":"3","DOI":"10.1016\/j.jcrs.2012.02.036"},{"doi-asserted-by":"publisher","key":"4","DOI":"10.1016\/j.jcrs.2005.03.058"},{"doi-asserted-by":"publisher","key":"5","DOI":"10.1111\/j.1475-1313.2009.00701.x"},{"doi-asserted-by":"publisher","key":"6","DOI":"10.1016\/j.optm.2009.04.100"},{"doi-asserted-by":"publisher","key":"7","DOI":"10.1016\/j.ajo.2009.04.028"},{"doi-asserted-by":"publisher","key":"8","DOI":"10.1016\/j.optom.2012.12.003"},{"doi-asserted-by":"publisher","key":"9","DOI":"10.1097\/OPX.0b013e3181f6f98f"},{"year":"2011","key":"10"},{"doi-asserted-by":"publisher","key":"11","DOI":"10.1136\/bjo.2008.152736"},{"doi-asserted-by":"publisher","key":"12","DOI":"10.1016\/j.jcrs.2007.10.031"},{"doi-asserted-by":"publisher","key":"13","DOI":"10.1016\/j.ophtha.2006.02.022"},{"year":"2006","key":"14"},{"year":"2011","key":"15"},{"issue":"8476","key":"16","first-page":"307","volume":"1","year":"1986","journal-title":"The Lancet"},{"doi-asserted-by":"publisher","key":"17","DOI":"10.1111\/j.1475-1313.2011.00851.x"},{"issue":"9","key":"18","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s004170000188","volume":"238","year":"2000","journal-title":"Graefe's Archive for Clinical and Experimental Ophthalmology"},{"doi-asserted-by":"publisher","key":"19","DOI":"10.1016\/S0886-3350(01)01214-7"},{"doi-asserted-by":"publisher","key":"20","DOI":"10.1016\/S0002-9394(98)00113-5"},{"doi-asserted-by":"publisher","key":"21","DOI":"10.1016\/j.clae.2013.04.001"},{"doi-asserted-by":"publisher","key":"22","DOI":"10.5005\/jp-journals-10025-1008"},{"doi-asserted-by":"publisher","key":"23","DOI":"10.3129\/i09-172"},{"doi-asserted-by":"publisher","key":"24","DOI":"10.1155\/2012\/430249"},{"issue":"11","key":"25","doi-asserted-by":"crossref","first-page":"1934","DOI":"10.1016\/j.jcrs.2012.06.049","volume":"38","year":"2012","journal-title":"Journal of Cataract & Refractive Surgery"},{"doi-asserted-by":"publisher","key":"26","DOI":"10.1016\/j.jcrs.2008.06.024"},{"doi-asserted-by":"publisher","key":"27","DOI":"10.1016\/j.jcrs.2012.07.024"},{"doi-asserted-by":"publisher","key":"28","DOI":"10.1155\/2014\/808646"},{"doi-asserted-by":"publisher","key":"29","DOI":"10.1016\/j.jcrs.2010.07.039"},{"doi-asserted-by":"publisher","key":"30","DOI":"10.1016\/j.ajo.2013.01.029"},{"doi-asserted-by":"publisher","key":"31","DOI":"10.1016\/j.jcrs.2010.08.053"},{"doi-asserted-by":"publisher","key":"32","DOI":"10.1016\/j.jcrs.2010.02.027"},{"doi-asserted-by":"publisher","key":"33","DOI":"10.3928\/15428877-20080101-08"},{"doi-asserted-by":"publisher","key":"34","DOI":"10.1016\/j.jcrs.2012.08.064"},{"year":"2004","key":"35"},{"year":"2008","key":"36"},{"doi-asserted-by":"publisher","key":"37","DOI":"10.1016\/j.jcrs.2012.11.019"},{"doi-asserted-by":"publisher","key":"38","DOI":"10.1016\/j.optom.2013.03.005"},{"doi-asserted-by":"publisher","key":"39","DOI":"10.1016\/j.jcrs.2003.06.004"},{"doi-asserted-by":"publisher","key":"40","DOI":"10.1111\/j.1444-0938.2009.00407.x"},{"doi-asserted-by":"publisher","key":"41","DOI":"10.1097\/01.icl.0000240501.07041.f8"}],"container-title":["BioMed Research International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/bmri\/2014\/498080.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/bmri\/2014\/498080.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/bmri\/2014\/498080.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,22]],"date-time":"2017-06-22T10:14:44Z","timestamp":1498126484000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.hindawi.com\/journals\/bmri\/2014\/498080\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014]]},"references-count":41,"alternative-id":["498080","498080"],"URL":"https:\/\/doi.org\/10.1155\/2014\/498080","relation":{},"ISSN":["2314-6133","2314-6141"],"issn-type":[{"type":"print","value":"2314-6133"},{"type":"electronic","value":"2314-6141"}],"subject":[],"published":{"date-parts":[[2014]]}}}