{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T00:19:17Z","timestamp":1769213957687,"version":"3.49.0"},"reference-count":19,"publisher":"Hindawi Limited","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"name":"Austrian Research Promotion Agency","award":["830161"],"award-info":[{"award-number":["830161"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Sensors"],"published-print":{"date-parts":[[2015]]},"abstract":"<jats:p>Pressure ulcers are a common skin disease which is associated with pain, reduced autonomy, social isolation, and reduced quality of life. There are several systems for monitoring of pressure ulcer-related risk factors on the market, but up to now no satisfactory solution is available, especially for people with medium pressure ulcer risk. We present a novel pressure ulcer risk assessment and prevention system, which combines the advantages of accelerometer and pressure sensors for monitoring pressure ulcer risk factors. Sensors are used for detection of repositionings of the person lying on the mattress. Sensor data are sent to a tablet where they are analysed and presented graphically. The system was evaluated in a long-term test at the homes of people of the target group. Results indicate that the system is able to detect movements of persons while lying in bed. Weak correlation in between mobility and Braden pressure ulcer risk was found (correlation factor = 0.31). From our data, long-term trends could be visualized as well as 24\u2009h mobility profiles. Such graphical illustrations might be helpful for caregivers in order to optimize care of people with medium to high pressure ulcer risk.<\/jats:p>","DOI":"10.1155\/2015\/106537","type":"journal-article","created":{"date-parts":[[2015,2,10]],"date-time":"2015-02-10T21:02:08Z","timestamp":1423602128000},"page":"1-8","source":"Crossref","is-referenced-by-count":8,"title":["An eHealth System for Pressure Ulcer Risk Assessment Based on Accelerometer and Pressure Data"],"prefix":"10.1155","volume":"2015","author":[{"given":"Dieter","family":"Hayn","sequence":"first","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology GmbH, Reininghausstr 20, 8020 Graz, Austria"}]},{"given":"Markus","family":"Falgenhauer","sequence":"additional","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology GmbH, Reininghausstr 20, 8020 Graz, Austria"}]},{"given":"J\u00fcrgen","family":"Morak","sequence":"additional","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology GmbH, Reininghausstr 20, 8020 Graz, Austria"}]},{"given":"Karin","family":"Wipfler","sequence":"additional","affiliation":[{"name":"Hilfswerk \u00d6sterreich, Apollog 4\/5, 1070 Vienna, Austria"}]},{"given":"Viktoria","family":"Willner","sequence":"additional","affiliation":[{"name":"Salzburg Research Forschungsgesellschaft mbH, Jakob-Haringerstra\u00dfe 5\/3, 5020 Salzburg, Austria"}]},{"given":"Walter","family":"Liebhart","sequence":"additional","affiliation":[{"name":"ilogs mobile software GmbH, Krone Platz 1I, 9020 Klagenfurt, Austria"}]},{"given":"G\u00fcnter","family":"Schreier","sequence":"additional","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology GmbH, Reininghausstr 20, 8020 Graz, Austria"}]}],"member":"98","reference":[{"key":"1","first-page":"179","volume-title":"Pr\u00e4valenz von Dekubitus","year":"2007"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.12968\/jowc.2013.22.7.361"},{"issue":"4","key":"3","first-page":"205","volume":"36","year":"1987","journal-title":"Nursing Research"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1089\/wound.2012.0385"},{"key":"5","series-title":"edited by E. Haesler","year":"2014"},{"key":"6","series-title":"WOCN Clinical Practice Guideline no. 2","year":"2010"},{"key":"7","year":"2010"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1007\/s10484-009-9124-z"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925x-11-90"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1097\/pts.0b013e318230e6ef"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtv.2013.05.002"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1080\/10400435.1993.10132213"},{"issue":"7212","key":"14","first-page":"1124","volume":"2","year":"1961","journal-title":"The Lancet"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2010.2044797"},{"issue":"3-4","key":"16","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/0020-7101(93)90021-W","volume":"32","year":"1993","journal-title":"International Journal of Bio-Medical Computing"},{"key":"17","first-page":"181","volume-title":"Mobile Akzelerometrie zur Messung der Lage in Ruhe und Schlaf","year":"2011"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.3233\/978-1-60750-837-3-640"},{"key":"24","first-page":"1033","volume":"192","year":"2013","journal-title":"Studies in Health Technology and Informatics"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1515\/bmt-2013-4245"}],"container-title":["Journal of Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2015\/106537.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2015\/106537.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2015\/106537.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,23]],"date-time":"2017-06-23T05:17:35Z","timestamp":1498195055000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.hindawi.com\/journals\/js\/2015\/106537\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015]]},"references-count":19,"alternative-id":["106537","106537"],"URL":"https:\/\/doi.org\/10.1155\/2015\/106537","relation":{},"ISSN":["1687-725X","1687-7268"],"issn-type":[{"value":"1687-725X","type":"print"},{"value":"1687-7268","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015]]}}}