{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T14:49:01Z","timestamp":1790002141473,"version":"4.0.1"},"reference-count":24,"publisher":"Wiley","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computational and Mathematical Methods in Medicine"],"published-print":{"date-parts":[[2016]]},"abstract":"<jats:p>Stress shielding is a well-known failure factor in hip implants. This work proposes a design concept for hip implants, using a combination of metallic stem with a polymer coating (polyether ether ketone (PEEK)). The proposed design concept is simulated using titanium alloy stems and PEEK coatings with thicknesses varying from 100 to 400\u2009<jats:italic>\u03bc<\/jats:italic>m. The Finite Element analysis of the cancellous bone surrounding the implant shows promising results. The effective von Mises stress increases between 81 and 92% for the complete volume of cancellous bone. When focusing on the proximal zone of the implant, the increased stress transmission to the cancellous bone reaches between 47 and 60%. This increment in load transferred to the bone can influence mineral bone loss due to stress shielding, minimizing such effect, and thus prolonging implant lifespan.<\/jats:p>","DOI":"10.1155\/2016\/6183679","type":"journal-article","created":{"date-parts":[[2016,3,14]],"date-time":"2016-03-14T17:01:25Z","timestamp":1457974885000},"page":"1-10","source":"Crossref","is-referenced-by-count":47,"title":["Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis"],"prefix":"10.1155","volume":"2016","author":[{"given":"Jesica","family":"Anguiano-Sanchez","sequence":"first","affiliation":[{"name":"Escuela de Ingenier\u00eda y Ciencias, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oscar","family":"Martinez-Romero","sequence":"additional","affiliation":[{"name":"Escuela de Ingenier\u00eda y Ciencias, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hector R.","family":"Siller","sequence":"additional","affiliation":[{"name":"Escuela de Ingenier\u00eda y Ciencias, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose A.","family":"Diaz-Elizondo","sequence":"additional","affiliation":[{"name":"Escuela de Medicina, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eduardo","family":"Flores-Villalba","sequence":"additional","affiliation":[{"name":"Escuela de Ingenier\u00eda y Ciencias, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"},{"name":"Escuela de Medicina, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2289-4239","authenticated-orcid":true,"given":"Ciro A.","family":"Rodriguez","sequence":"additional","affiliation":[{"name":"Escuela de Ingenier\u00eda y Ciencias, Tecnol\u00f3gico de Monterrey, Avenida Eugenio Garza Sada 2501, 64849 Monterrey, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","reference":[{"key":"1","year":"2012"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.2106\/jbjs.f.00222"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2013.12.054"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(87)90030-3"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1016\/s0021-9290(00)00110-x"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1016\/s0021-9290(01)00072-0"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.03.038"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2013.04.034"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.31146"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.09.019"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2007.07.013"},{"key":"12","first-page":"17","volume":"141","year":"1979","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmatsci.2006.07.001"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1115\/1.1372701"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-012-3955-0"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1016\/j.matlet.2006.01.048"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2012.09.005"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.3233\/abb-140085"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/250929"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1016\/j.engfracmech.2003.08.003"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1177\/0954411911413060"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.90b11.20068"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2004.08.008"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1016\/j.surfcoat.2008.11.005"}],"container-title":["Computational and Mathematical Methods in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2016\/6183679.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2016\/6183679.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2016\/6183679.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2016,8,18]],"date-time":"2016-08-18T18:21:08Z","timestamp":1471544468000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.hindawi.com\/journals\/cmmm\/2016\/6183679\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"references-count":24,"alternative-id":["6183679","6183679"],"URL":"https:\/\/doi.org\/10.1155\/2016\/6183679","relation":{},"ISSN":["1748-670X","1748-6718"],"issn-type":[{"value":"1748-670X","type":"print"},{"value":"1748-6718","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016]]}}}