{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T21:03:28Z","timestamp":1771707808454,"version":"3.50.1"},"reference-count":21,"publisher":"Wiley","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13GW0095A"],"award-info":[{"award-number":["13GW0095A"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computational and Mathematical Methods in Medicine"],"published-print":{"date-parts":[[2016]]},"abstract":"<jats:p>Computational Fluid Dynamics is intensively used to deepen the understanding of aneurysm growth and rupture in order to support physicians during therapy planning. However, numerous studies considering only the hemodynamics within the vessel lumen found no satisfactory criteria for rupture risk assessment. To improve available simulation models, the rigid vessel wall assumption has been discarded in this work and patient-specific wall thickness is considered within the simulation. For this purpose, a ruptured intracranial aneurysm was prepared ex vivo, followed by the acquisition of local wall thickness using<jats:italic>\u03bc<\/jats:italic>CT. The segmented inner and outer vessel surfaces served as solid domain for the fluid-structure interaction (FSI) simulation. To compare wall stress distributions within the aneurysm wall and at the rupture site, FSI computations are repeated in a virtual model using a constant wall thickness approach. Although the wall stresses obtained by the two approaches\u2014when averaged over the complete aneurysm sac\u2014are in very good agreement, strong differences occur in their distribution. Accounting for the real wall thickness distribution, the rupture site exhibits much higher stress values compared to the configuration with constant wall thickness. The study reveals the importance of geometry reconstruction and accurate description of wall thickness in FSI simulations.<\/jats:p>","DOI":"10.1155\/2016\/9854539","type":"journal-article","created":{"date-parts":[[2016,9,18]],"date-time":"2016-09-18T17:02:22Z","timestamp":1474218142000},"page":"1-8","source":"Crossref","is-referenced-by-count":41,"title":["Fluid-Structure Simulations of a Ruptured Intracranial Aneurysm: Constant versus Patient-Specific Wall Thickness"],"prefix":"10.1155","volume":"2016","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9757-7564","authenticated-orcid":true,"given":"S.","family":"Vo\u00df","sequence":"first","affiliation":[{"name":"Department of Fluid Dynamics and Technical Flows, University of Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9059-015X","authenticated-orcid":true,"given":"S.","family":"Gla\u00dfer","sequence":"additional","affiliation":[{"name":"Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Hoffmann","sequence":"additional","affiliation":[{"name":"Institute of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Beuing","sequence":"additional","affiliation":[{"name":"Institute of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9215-1161","authenticated-orcid":true,"given":"S.","family":"Weigand","sequence":"additional","affiliation":[{"name":"Institute of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Jachau","sequence":"additional","affiliation":[{"name":"Institute of Forensic Medicine, University Hospital Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Preim","sequence":"additional","affiliation":[{"name":"Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7599-9574","authenticated-orcid":true,"given":"D.","family":"Th\u00e9venin","sequence":"additional","affiliation":[{"name":"Department of Fluid Dynamics and Technical Flows, University of Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Janiga","sequence":"additional","affiliation":[{"name":"Department of Fluid Dynamics and Technical Flows, University of Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Berg","sequence":"additional","affiliation":[{"name":"Department of Fluid Dynamics and Technical Flows, University of Magdeburg, Magdeburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-014-1093-6"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4031794"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.110.592923"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2419"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.a3558"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.a1819"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1007\/s00401-011-0939-3"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1007\/s00466-009-0419-y"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011247"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1115\/1.4024578"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1109\/MPUL.2011.942929"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1115\/1.4026108"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-015-1288-5"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1007\/s00466-009-0421-4"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1002\/fld.1786"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1007\/s00466-008-0325-8"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.07.026"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1515\/bmt-2012-0119"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2013.07.016"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-012-0632-2"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.a3949"}],"container-title":["Computational and Mathematical Methods in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2016\/9854539.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2016\/9854539.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2016\/9854539.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2016,9,18]],"date-time":"2016-09-18T17:02:24Z","timestamp":1474218144000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/cmmm\/2016\/9854539\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"references-count":21,"alternative-id":["9854539","9854539"],"URL":"https:\/\/doi.org\/10.1155\/2016\/9854539","relation":{},"ISSN":["1748-670X","1748-6718"],"issn-type":[{"value":"1748-670X","type":"print"},{"value":"1748-6718","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016]]}}}