{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,22]],"date-time":"2025-04-22T05:47:01Z","timestamp":1745300821826,"version":"3.37.3"},"reference-count":35,"publisher":"Wiley","license":[{"start":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T00:00:00Z","timestamp":1543449600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100012964","name":"Minist\u00e8re de l\u2019Enseignement Sup\u00e9rieur et de la Recherche Scientifique","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100012964","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Sensors"],"published-print":{"date-parts":[[2018,11,29]]},"abstract":"<jats:p>Impedance cardiography (ICG) is a noninvasive method for monitoring mechanical function of the heart with the use of electrical bioimpedance measurements. This paper presents the feasibility of recording an ICG signal simultaneously with electrocardiogram signal (ECG) using the same electrodes for both measurements, for a total of five electrodes rather than eight electrodes. The device used is the Z-RPI. The results present good performance and show waveforms presenting high similarity with the different signals reported using different electrodes for acquisition; the heart rate values were calculated and they present accurate evaluation between the ECG and ICG heart rates. The hemodynamics and cardiac parameter results present similitude with the physiological parameters for healthy people reported in the literature. The possibility of reducing number of electrodes used for ICG measurement is an encouraging step to enabling wearable and personal health monitoring solutions.<\/jats:p>","DOI":"10.1155\/2018\/3269534","type":"journal-article","created":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T18:30:26Z","timestamp":1543516226000},"page":"1-7","source":"Crossref","is-referenced-by-count":15,"title":["Simultaneous Recording of ICG and ECG Using Z-RPI Device with Minimum Number of Electrodes"],"prefix":"10.1155","volume":"2018","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6640-1868","authenticated-orcid":true,"given":"Abdelakram","family":"Hafid","sequence":"first","affiliation":[{"name":"Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria"}]},{"given":"Sara","family":"Benouar","sequence":"additional","affiliation":[{"name":"Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria"}]},{"given":"Malika","family":"Kedir-Talha","sequence":"additional","affiliation":[{"name":"Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria"}]},{"given":"Mokhtar","family":"Attari","sequence":"additional","affiliation":[{"name":"Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, Algiers, Algeria"}]},{"given":"Fernando","family":"Seoane","sequence":"additional","affiliation":[{"name":"Swedish School of Textiles, University of Bor\u00e5s, 50190 Bor\u00e5s, Sweden"},{"name":"The Department for Clinical Science, Intervention and Technology, Karolinska Institutet, 14186 Stockholm, Sweden"},{"name":"Department Biomedical Engineering, Karolinska University Hospital, 14186 Stockholm, Sweden"}]}],"member":"311","reference":[{"year":"2016","key":"1"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.12860\/jnp.2014.19"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/381251"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1016\/j.clnu.2004.06.004"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/224\/1\/012140"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/613247"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2004.824148"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.2.6.811"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-8986.1990.tb02171.x"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-11987-3_3"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/33\/4\/629"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1007\/BF02510508"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.41.4.651"},{"year":"2009","key":"14"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.1985.325532"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/34\/9\/R47"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/36\/3\/513"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2015.2502538"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/35\/6\/1181"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1109\/JBHI.2017.2783949"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.3109\/03091902.2014.990161"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.3233\/978-1-61499-597-5-30"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.5617\/jeb.542"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1016\/j.cardfail.2013.06.284"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijpsycho.2012.11.001"},{"key":"30","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-8986.1990.tb02173.x"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.3758\/bf03195525"},{"issue":"9","key":"32","first-page":"410","volume":"9","year":"1974","journal-title":"Bio-Medical Engineering"},{"key":"33","doi-asserted-by":"publisher","DOI":"10.1007\/BF02441549"},{"key":"35","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-8986.2006.00468.x"},{"key":"36","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/29\/6\/S32"},{"key":"40","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/224\/1\/012117"},{"key":"41","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.1986.325869"},{"key":"42","doi-asserted-by":"publisher","DOI":"10.1007\/BF02524429"},{"year":"2016","key":"43"}],"container-title":["Journal of Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/3269534.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/3269534.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/3269534.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T18:30:29Z","timestamp":1543516229000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/js\/2018\/3269534\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,29]]},"references-count":35,"alternative-id":["3269534","3269534"],"URL":"https:\/\/doi.org\/10.1155\/2018\/3269534","relation":{},"ISSN":["1687-725X","1687-7268"],"issn-type":[{"type":"print","value":"1687-725X"},{"type":"electronic","value":"1687-7268"}],"subject":[],"published":{"date-parts":[[2018,11,29]]}}}