{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:36:01Z","timestamp":1740148561997,"version":"3.37.3"},"reference-count":25,"publisher":"Wiley","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100011841","name":"Xinxiang Medical University","doi-asserted-by":"crossref","award":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"],"award-info":[{"award-number":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"]}],"id":[{"id":"10.13039\/501100011841","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100006407","name":"Natural Science Foundation of Henan Province","doi-asserted-by":"publisher","award":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"],"award-info":[{"award-number":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"]}],"id":[{"id":"10.13039\/501100006407","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Human comfort study by elevator transportation based on multi-body dynamics","award":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"],"award-info":[{"award-number":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"]}]},{"name":"Multi-DOF rehabilitation patient transfer device dynamics characteristic and human-machine safety comfort research","award":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"],"award-info":[{"award-number":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"]}]},{"name":"Human machine dynamic characteristics of multi degree of freedom rehabilitation displacement device","award":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"],"award-info":[{"award-number":["2018-BME-KFKT-05","152102310357","2015KYJH33","505140","172102310542"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Sensors"],"published-print":{"date-parts":[[2018]]},"abstract":"<jats:p>The trend item of a long-term vibration signal is difficult to remove. This paper proposes a piecewise integration method to remove trend items. Examples of direct integration without trend item removal, global integration after piecewise polynomial fitting with trend item removal, and direct integration after piecewise polynomial fitting with trend item removal were simulated. The results showed that direct integration of the fitted piecewise polynomial provided greater acceleration and displacement precision than the other two integration methods. A vibration test was then performed on a special equipment cab. The results indicated that direct integration by piecewise polynomial fitting with trend item removal was highly consistent with the measured signal data. However, the direct integration method without trend item removal resulted in signal distortion. The proposed method can help with frequency domain analysis of vibration signals and modal parameter identification for such equipment.<\/jats:p>","DOI":"10.1155\/2018\/3417692","type":"journal-article","created":{"date-parts":[[2018,4,12]],"date-time":"2018-04-12T23:34:04Z","timestamp":1523576044000},"page":"1-8","source":"Crossref","is-referenced-by-count":4,"title":["Piecewise Polynomial Fitting with Trend Item Removal and Its Application in a Cab Vibration Test"],"prefix":"10.1155","volume":"2018","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6634-3159","authenticated-orcid":true,"given":"Wu","family":"Ren","sequence":"first","affiliation":[{"name":"School of Biomedical Engineering, Key Lab of Neurosense and Control, Xinxiang Key Laboratory of Biomedical Information Research, Xinxiang Medical University, Xinxiang, Henan 453003, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiongqiong","family":"Ren","sequence":"additional","affiliation":[{"name":"School of Biomedical Engineering, Key Lab of Neurosense and Control, Xinxiang Key Laboratory of Biomedical Information Research, Xinxiang Medical University, Xinxiang, Henan 453003, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Han","sequence":"additional","affiliation":[{"name":"School of Biomedical Engineering, Key Lab of Neurosense and Control, Xinxiang Key Laboratory of Biomedical Information Research, Xinxiang Medical University, Xinxiang, Henan 453003, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Liu","sequence":"additional","affiliation":[{"name":"The First Affiliated Hospital of Xinxiang Medical University, Xinxiang, Henan 453100, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"Peng","sequence":"additional","affiliation":[{"name":"Hunan Special Equipment Inspection and Testing Research Institute Zhangjiajie branch, Zhangjiajie, Hunan 427000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"year":"2011","key":"1"},{"year":"2010","key":"2"},{"year":"2008","key":"3"},{"issue":"5","key":"4","first-page":"69","volume":"29","year":"2007","journal-title":"Xiandai leida(Modern radar)"},{"issue":"1","key":"5","first-page":"12","volume":"07","year":"2007","journal-title":"Journal of Scientific Instrument"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1115\/1.1410369"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1155\/2004\/523692"},{"issue":"5","key":"10","first-page":"247","volume":"38","year":"2004","journal-title":"Faculteit toegepaste wetenschappen"},{"year":"2011","key":"11"},{"issue":"1","key":"12","first-page":"24","volume":"38","year":"2004","journal-title":"Sound and Vibration"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsv.2012.09.009"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/437917"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jkss.2015.02.001"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1111\/rssb.12098"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1002\/jrs.5130"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1016\/j.patcog.2017.07.002"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ergon.2017.02.002"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1177\/0959651813506188"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jterra.2016.10.003"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1016\/j.asoc.2012.11.028"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1002\/pts.2202"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnonlinmec.2016.10.014"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1007\/s11044-012-9337-4"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ymssp.2009.02.015"},{"issue":"10","key":"27","first-page":"8","volume":"17","year":"2011","journal-title":"Metrology & measurement technique"}],"container-title":["Journal of Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/3417692.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/3417692.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/3417692.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,19]],"date-time":"2020-05-19T08:19:14Z","timestamp":1589876354000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/js\/2018\/3417692\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":25,"alternative-id":["3417692","3417692"],"URL":"https:\/\/doi.org\/10.1155\/2018\/3417692","relation":{},"ISSN":["1687-725X","1687-7268"],"issn-type":[{"type":"print","value":"1687-725X"},{"type":"electronic","value":"1687-7268"}],"subject":[],"published":{"date-parts":[[2018]]}}}