{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T13:29:11Z","timestamp":1762522151376,"version":"3.37.3"},"reference-count":10,"publisher":"Wiley","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Third Batch Innovative Research Team Introduction Program of Dongguan City in 2015","award":["2017360004004","2016B090918067","2015A030313675"],"award-info":[{"award-number":["2017360004004","2016B090918067","2015A030313675"]}]},{"name":"Special Funding of Collaborative Innovation and Platform Circumstance Construction of Guangdong Province","award":["2017360004004","2016B090918067","2015A030313675"],"award-info":[{"award-number":["2017360004004","2016B090918067","2015A030313675"]}]},{"DOI":"10.13039\/501100003453","name":"Natural Science Foundation of Guangdong Province","doi-asserted-by":"publisher","award":["2017360004004","2016B090918067","2015A030313675"],"award-info":[{"award-number":["2017360004004","2016B090918067","2015A030313675"]}],"id":[{"id":"10.13039\/501100003453","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Electrical and Computer Engineering"],"published-print":{"date-parts":[[2018]]},"abstract":"<jats:p>To realize the maximum power output of a grid-connected inverter, the MPPT (maximum power point tracking) control method is needed. The perturbation and observation (P&amp;O) method can cause the inverter operating point to oscillate near the maximum power. In this paper, the fuzzy control P&amp;O method is proposed, and the fuzzy control algorithm is applied to the disturbance observation method. The simulation results of the P&amp;O method with fuzzy control and the traditional P&amp;O method prove that not only can the new method reduce the power loss caused by inverter oscillation during maximum power point tracking, but also it has the advantage of speed. Inductive loads in the post-grid-connected stage cause grid-connected current distortion. A fuzzy control algorithm is added to the traditional deadbeat grid-connected control method to improve the quality of the system\u2019s grid-connected operation. The fuzzy deadbeat control method is verified by experiments, and the harmonic current of the grid-connected current is less than 3%.<\/jats:p>","DOI":"10.1155\/2018\/3806372","type":"journal-article","created":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T18:31:22Z","timestamp":1519929082000},"page":"1-10","source":"Crossref","is-referenced-by-count":5,"title":["Application of Fuzzy Control in a Photovoltaic Grid-Connected Inverter"],"prefix":"10.1155","volume":"2018","author":[{"given":"Zhaohong","family":"Zheng","sequence":"first","affiliation":[{"name":"School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianxia","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6532-3917","authenticated-orcid":true,"given":"Jiaxiang","family":"Xue","sequence":"additional","affiliation":[{"name":"School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510641, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2011.06.025"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1080\/00423114.2011.642806"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2014.11.050"},{"issue":"3","key":"4","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1002\/ep.12340","volume":"35","year":"2016","journal-title":"Environmental Progress & Sustainable Energy"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1109\/MIE.2009.933882"},{"issue":"3","key":"6","first-page":"451","volume":"60","year":"2014","journal-title":"Annual Review of Microbiology"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2012.2192282"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1016\/j.solener.2016.01.007"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.11591\/ijpeds.v3i2.3606"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1016\/j.solener.2012.03.018"}],"container-title":["Journal of Electrical and Computer Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/jece\/2018\/3806372.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jece\/2018\/3806372.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jece\/2018\/3806372.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T18:31:27Z","timestamp":1519929087000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/jece\/2018\/3806372\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":10,"alternative-id":["3806372","3806372"],"URL":"https:\/\/doi.org\/10.1155\/2018\/3806372","relation":{},"ISSN":["2090-0147","2090-0155"],"issn-type":[{"type":"print","value":"2090-0147"},{"type":"electronic","value":"2090-0155"}],"subject":[],"published":{"date-parts":[[2018]]}}}