{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T19:14:39Z","timestamp":1762542879034,"version":"3.37.3"},"reference-count":40,"publisher":"Wiley","license":[{"start":{"date-parts":[[2018,7,9]],"date-time":"2018-07-09T00:00:00Z","timestamp":1531094400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003329","name":"Ministerio de Econom\u00eda y Competitividad","doi-asserted-by":"publisher","award":["DPI2015\ufffd68397-R","MAT2015-64139-C4-3-R"],"award-info":[{"award-number":["DPI2015\ufffd68397-R","MAT2015-64139-C4-3-R"]}],"id":[{"id":"10.13039\/501100003329","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008530","name":"European Regional Development Fund","doi-asserted-by":"publisher","award":["DPI2015\ufffd68397-R","MAT2015-64139-C4-3-R"],"award-info":[{"award-number":["DPI2015\ufffd68397-R","MAT2015-64139-C4-3-R"]}],"id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Spanish Government\/FEDER funds","award":["DPI2015\ufffd68397-R","MAT2015-64139-C4-3-R"],"award-info":[{"award-number":["DPI2015\ufffd68397-R","MAT2015-64139-C4-3-R"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Sensors"],"published-print":{"date-parts":[[2018,7,9]]},"abstract":"<jats:p>Continuous ECG monitoring can play an important role in the rapid detection of pathological signatures and arrhythmias. Current systems use electrodes with limitations in wearable long-term applications and spatial selectivity. In this work, two sizes of textile concentric ring electrodes (TCRE42 and TCRE50) were developed and tested for monitoring cardiac activity. The low-cost devices were found to be easy to implement and to potentially have the advantages of textile electrodes for being lightweight, stretchable, adjustable, washable, and long-lasting. Both TCREs yielded similar signal detectability of different ECG waves. The optimal <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M1\"><mml:mi>P<\/mml:mi><\/mml:math> wave recording area (OPA) for detecting signals was on the upper right chest. Although the absolute signal amplitude of TCRE records was smaller than that of lead II, normalized amplitude in the OPA is similar for <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M2\"><mml:mi>T<\/mml:mi><\/mml:math> wave and higher for <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M3\"><mml:mi>P<\/mml:mi><\/mml:math> wave. The TCREs also allowed better analysis of <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M4\"><mml:mi>P<\/mml:mi><\/mml:math> wave morphology and were able to detect more right and left atrial depolarization waves. TCRE48 showed slightly better detectability, normalized amplitude, and spatial selectivity than TCRE50 within the OPA. The authors consider the TCRE suitable for use in ubiquitous mobile health care systems, especially for atrial activity monitoring and diagnosis.<\/jats:p>","DOI":"10.1155\/2018\/7290867","type":"journal-article","created":{"date-parts":[[2018,7,9]],"date-time":"2018-07-09T19:34:22Z","timestamp":1531164862000},"page":"1-9","source":"Crossref","is-referenced-by-count":6,"title":["Textile Concentric Ring Electrodes: Influence of Position and Electrode Size on Cardiac Activity Monitoring"],"prefix":"10.1155","volume":"2018","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9362-5055","authenticated-orcid":true,"given":"Gema","family":"Prats-Boluda","sequence":"first","affiliation":[{"name":"Centro de Investigaci\u00f3n e Innovaci\u00f3n en Bioingenier\u00eda, Universitat Polit\u00e8cnica de Val\u00e8ncia, Valencia 46022, Spain"}]},{"given":"Yiyao","family":"Ye-Lin","sequence":"additional","affiliation":[{"name":"Centro de Investigaci\u00f3n e Innovaci\u00f3n en Bioingenier\u00eda, Universitat Polit\u00e8cnica de Val\u00e8ncia, Valencia 46022, Spain"}]},{"given":"Francisco","family":"Pradas-Novella","sequence":"additional","affiliation":[{"name":"Centro de Investigaci\u00f3n e Innovaci\u00f3n en Bioingenier\u00eda, Universitat Polit\u00e8cnica de Val\u00e8ncia, Valencia 46022, Spain"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9745-8485","authenticated-orcid":true,"given":"Eduardo","family":"Garcia-Breijo","sequence":"additional","affiliation":[{"name":"Instituto Interuniversitario de Investigaci\u00f3n de Reconocimiento Molecular y Desarrollo Tecnol\u00f3gico (IDM), Universitat Polit\u00e8cnica de Val\u00e8ncia, Valencia 46022, Spain"}]},{"given":"Javier","family":"Garcia-Casado","sequence":"additional","affiliation":[{"name":"Centro de Investigaci\u00f3n e Innovaci\u00f3n en Bioingenier\u00eda, Universitat Polit\u00e8cnica de Val\u00e8ncia, Valencia 46022, Spain"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1093\/acprof:oso\/9780195058239.003.0019"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925X-12-26"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/21\/2\/307"},{"year":"2010","key":"4"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1109\/MCOM.2012.6122530"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1002\/adma.201400633"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2005.854512"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2003.10.071"},{"year":"2012","key":"9"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.3002152"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.3390\/s16060858"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/28\/5\/006"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1109\/10.168684"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/27\/2\/025705"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2016.11.009"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.3390\/s18020396"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-014-1130-5"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1111\/pace.13133"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.07.026"},{"issue":"1","key":"20","first-page":"76","volume":"33","year":"1999","journal-title":"Biomedical Instrumentation & Technology"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2010.11.009"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.201700552"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.3390\/s18010300"},{"issue":"26","key":"24","first-page":"71","volume":"8","year":"2016","journal-title":"International Journal on \u201cTechnical and Physical Problems of Engineering\u201d"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2013.2289072"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1108\/MI-03-2015-0021"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1109\/tbme.1985.325532"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/31\/5\/005"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-015-0072-y"},{"key":"30","first-page":"199","volume":"22","year":"2002","journal-title":"Journal of Medical and Biological Engineering"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.3390\/ma11020256"},{"key":"32","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2018.2806950"},{"key":"33","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/36\/3\/513"},{"key":"34","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2012.2190288"},{"key":"35","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.00864.2013"},{"key":"36","doi-asserted-by":"publisher","DOI":"10.1111\/j.1542-474X.2009.00345.x"},{"key":"37","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.22.4.598"},{"key":"38","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcme.2015.10.006"},{"key":"39","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2014.07.010"},{"key":"40","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2014.08.001"}],"container-title":["Journal of Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/7290867.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/7290867.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/js\/2018\/7290867.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,7,9]],"date-time":"2018-07-09T19:34:29Z","timestamp":1531164869000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/js\/2018\/7290867\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,9]]},"references-count":40,"alternative-id":["7290867","7290867"],"URL":"https:\/\/doi.org\/10.1155\/2018\/7290867","relation":{},"ISSN":["1687-725X","1687-7268"],"issn-type":[{"type":"print","value":"1687-725X"},{"type":"electronic","value":"1687-7268"}],"subject":[],"published":{"date-parts":[[2018,7,9]]}}}