{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T11:13:34Z","timestamp":1772190814556,"version":"3.50.1"},"reference-count":20,"publisher":"Wiley","license":[{"start":{"date-parts":[[2019,3,3]],"date-time":"2019-03-03T00:00:00Z","timestamp":1551571200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61571182"],"award-info":[{"award-number":["61571182"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["BSQD14033"],"award-info":[{"award-number":["BSQD14033"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002948","name":"Hubei University of Technology","doi-asserted-by":"publisher","award":["61571182"],"award-info":[{"award-number":["61571182"]}],"id":[{"id":"10.13039\/501100002948","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002948","name":"Hubei University of Technology","doi-asserted-by":"publisher","award":["BSQD14033"],"award-info":[{"award-number":["BSQD14033"]}],"id":[{"id":"10.13039\/501100002948","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computational and Mathematical Methods in Medicine"],"published-print":{"date-parts":[[2019,3,3]]},"abstract":"<jats:p>One of the major noise components in electrocardiogram (ECG) is the baseline wander (BW). Effective methods for suppressing BW include the wavelet-based (WT) and the mathematical morphological filtering-based (MMF) algorithms. However, the <jats:italic>T<\/jats:italic> waveform distortions introduced by the WT and the rectangular\/trapezoidal distortions introduced by MMF degrade the quality of the output signal. Hence, in this study, we introduce a method by combining the MMF and WT to overcome the shortcomings of both existing methods. To demonstrate the effectiveness of the proposed method, artificial ECG signals containing a clinical BW are used for numerical simulation, and we also create a realistic model of baseline wander to compare the proposed method with other state-of-the-art methods commonly used in the literature. The results show that the BW suppression effect of the proposed method is better than that of the others. Also, the new method is capable of preserving the outline of the BW and avoiding waveform distortions caused by the morphology filter, thereby obtaining an enhanced quality of ECG.<\/jats:p>","DOI":"10.1155\/2019\/7196156","type":"journal-article","created":{"date-parts":[[2019,3,3]],"date-time":"2019-03-03T18:34:55Z","timestamp":1551638095000},"page":"1-7","source":"Crossref","is-referenced-by-count":46,"title":["Electrocardiogram Baseline Wander Suppression Based on the Combination of Morphological and Wavelet Transformation Based Filtering"],"prefix":"10.1155","volume":"2019","author":[{"given":"Xiang-kui","family":"Wan","sequence":"first","affiliation":[{"name":"Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan 430068, China"},{"name":"Hubei Collaborative Innovation Center for High-efficiency Utilization of Solar Energy, Hubei University of Technology, Wuhan 430068, China"},{"name":"Hubei Power Grid Intelligent Control and Equipment Engineering Technology Research Center, Wuhan 430068, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haibo","family":"Wu","sequence":"additional","affiliation":[{"name":"Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan 430068, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Qiao","sequence":"additional","affiliation":[{"name":"Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan 430068, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0087-2680","authenticated-orcid":true,"given":"Feng-cong","family":"Li","sequence":"additional","affiliation":[{"name":"Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan 430068, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Li","sequence":"additional","affiliation":[{"name":"Faculty of Health, Engineering and Sciences, University of Southern Queensland, Toowoomba, QLD 4350, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yue-wen","family":"Yan","sequence":"additional","affiliation":[{"name":"Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan 430068, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia-xin","family":"Wei","sequence":"additional","affiliation":[{"name":"Hubei Key Laboratory for High-efficiency Utilization of Solar Energy and Operation Control of Energy Storage System, Hubei University of Technology, Wuhan 430068, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","first-page":"696","volume":"5","year":"1998","journal-title":"IEEE Access"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1049\/el:20082709"},{"key":"4","first-page":"381","volume":"5","year":"2009","journal-title":"Space Medicine & Medical Engineering"},{"issue":"3","key":"5","first-page":"333","volume":"22","year":"2006","journal-title":"Signal Processing"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.3109\/03091900903336886"},{"key":"7","first-page":"1566","volume":"10","year":"2007","journal-title":"Progress in Modern Biomedicine"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1155\/2007\/41274"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1007\/s13246-010-0033-5"},{"key":"10","first-page":"65","volume":"45","year":"2009","journal-title":"Biomedical Sciences Instrumentation"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1016\/s0010-4825(02)00034-3"},{"key":"12","first-page":"428","volume":"9","year":"2014","journal-title":"Acta Physica Sinica"},{"key":"13","first-page":"100","volume":"2","year":"2012","journal-title":"Computer Technology and Development"},{"key":"14","first-page":"185","volume":"17","year":"1990","journal-title":"Computers in Cardiology"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2016.01.046"},{"key":"16","first-page":"381","volume":"11","year":"1984","journal-title":"Computers in Cardiology"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/9295029"},{"issue":"2","key":"18","first-page":"356","volume":"2","year":"2008","journal-title":"International Journal of Circuits, Systems And Signal Processing"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1007\/bf02524427"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.101.23.e215"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1109\/10.900246"}],"container-title":["Computational and Mathematical Methods in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2019\/7196156.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2019\/7196156.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2019\/7196156.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,3,3]],"date-time":"2019-03-03T18:35:03Z","timestamp":1551638103000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/cmmm\/2019\/7196156\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,3]]},"references-count":20,"alternative-id":["7196156","7196156"],"URL":"https:\/\/doi.org\/10.1155\/2019\/7196156","relation":{},"ISSN":["1748-670X","1748-6718"],"issn-type":[{"value":"1748-670X","type":"print"},{"value":"1748-6718","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,3]]}}}