{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T02:38:12Z","timestamp":1747190292885,"version":"3.40.5"},"reference-count":21,"publisher":"Wiley","license":[{"start":{"date-parts":[[2020,10,10]],"date-time":"2020-10-10T00:00:00Z","timestamp":1602288000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Technology Project of Yunnan Power Grid Co., Ltd.","award":["0560002018030301XT00120"],"award-info":[{"award-number":["0560002018030301XT00120"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Complexity"],"published-print":{"date-parts":[[2020,10,10]]},"abstract":"<jats:p>In view of the photovoltaic grid-connected power system, the transient frequency stability of the system is analyzed in this paper. First, the photovoltaic grid-connected power system was modeled and analyzed. On this basis, the maximum frequency deviation is used as the index to determine the interval in which the system accommodates the maximum photovoltaic capacity, and the influence of frequency stability of the high-permeability photovoltaic high disturbance system is studied. Second, the evaluation and prediction methods of frequency dynamic characteristics of photovoltaic access nodes based on surface fitting are proposed, and the critical values of high penetration photovoltaic access for different grid points are given. Finally, an improvement measure based on the optimization of the frequency modulation parameters of large-capacity units is proposed, and the effectiveness of the proposed method in improving the transient frequency stability of the system after photovoltaic access is verified by the IEEE 39-standard system.<\/jats:p>","DOI":"10.1155\/2020\/5641596","type":"journal-article","created":{"date-parts":[[2020,10,12]],"date-time":"2020-10-12T19:50:07Z","timestamp":1602532207000},"page":"1-10","source":"Crossref","is-referenced-by-count":5,"title":["Cyber-Enabled Intelligence Control and Security Optimization for Complex Microgrid Networks Transient Frequency Stability Analysis of Power Systems considering Photovoltaic Grid Connection"],"prefix":"10.1155","volume":"2020","author":[{"given":"Jun","family":"Wu","sequence":"first","affiliation":[{"name":"School of Electrical Engineering & Automation, Wuhan University, Wuhan 430072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4711-8076","authenticated-orcid":true,"given":"Xiangyu","family":"Xing","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering & Automation, Wuhan University, Wuhan 430072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen","family":"Wu","sequence":"additional","affiliation":[{"name":"Yunnan Power Grid Co., Ltd., Kunming 650000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baolin","family":"Li","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering & Automation, Wuhan University, Wuhan 430072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Huang","sequence":"additional","affiliation":[{"name":"Yunnan Power Grid Co., Ltd., Kunming 650000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peiying","family":"Gan","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering & Automation, Wuhan University, Wuhan 430072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Zhou","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering & Automation, Wuhan University, Wuhan 430072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"doi-asserted-by":"publisher","key":"1","DOI":"10.1109\/tsg.2020.2966691"},{"doi-asserted-by":"publisher","key":"2","DOI":"10.1109\/tii.2020.2969458"},{"doi-asserted-by":"publisher","key":"3","DOI":"10.1109\/tii.2019.2908666"},{"doi-asserted-by":"publisher","key":"4","DOI":"10.1155\/2015\/586260"},{"issue":"8","key":"5","first-page":"47","article-title":"A review of photovoltaic power generation system models","volume":"35","author":"D. W. Liu","year":"2011","journal-title":"Power System Technology"},{"doi-asserted-by":"publisher","key":"6","DOI":"10.1109\/tr.1982.5221344"},{"issue":"1","key":"7","first-page":"1","article-title":"Summary of the influence of large scale photovoltaic power generation on power system","volume":"34","author":"M. Ding","year":"2014","journal-title":"Proceedings of Chinese Society for Electrical Engineering"},{"issue":"6","key":"8","first-page":"80","article-title":"Photovoltaic grid-connected transient stability calculation model based on MATLAB-PSASP","volume":"32","author":"W. Zhang","year":"2012","journal-title":"Electrical Power Automation Equation"},{"issue":"34","key":"9","first-page":"1","article-title":"Combined modeling and equivalence of wind and light storage combined power generation system","volume":"31","author":"H. H. Wang","year":"2011","journal-title":"Proceedings of Chinese Society for Electrical Engineering"},{"doi-asserted-by":"publisher","key":"10","DOI":"10.1109\/tia.2015.2458954"},{"doi-asserted-by":"publisher","key":"11","DOI":"10.1109\/tie.2008.928100"},{"doi-asserted-by":"publisher","key":"12","DOI":"10.1109\/tpel.2005.861185"},{"doi-asserted-by":"publisher","key":"13","DOI":"10.4028\/www.scientific.net\/amm.785.403"},{"doi-asserted-by":"crossref","unstructured":"BankJ.MatherB.KellerJ.CoddingtonM.High penetration photovoltaic case study report2013Office of Scientific & Technical InformationTechnical Report","key":"14","DOI":"10.2172\/1062441"},{"doi-asserted-by":"publisher","key":"15","DOI":"10.1080\/02286203.2016.1261219"},{"doi-asserted-by":"publisher","key":"16","DOI":"10.1109\/tec.2009.2026616"},{"issue":"16","key":"17","first-page":"58","article-title":"Study on dynamic characteristics of power system power frequency","volume":"33","author":"H. F. Zhou","year":"2009","journal-title":"Power System Technology"},{"unstructured":"DuY. W.Research on frequency safety and stability characteristics and control of power grid under new energy access conditions2017Beijing, ChinaNorth China Electric Power UniversityM. S. thesis","key":"18"},{"issue":"2","key":"19","first-page":"538","article-title":"Control technology of optical storage grid-connected power generation based on virtual synchronous generator","volume":"33","author":"W. Q. Chen","year":"2018","journal-title":"Transactions of Nonferrous Metals Society of China"},{"issue":"11","key":"20","first-page":"4064","article-title":"Dynamic frequency characteristics and countermeasures of photovoltaic high-permeability grid","volume":"43","author":"C. Zheng","year":"2019","journal-title":"Power System Technology"},{"unstructured":"LiC. G.Research on transient frequency stability assessment and control of power system2012Jinan, ChinaShandong UniversityPh. D. thesis","key":"21"}],"container-title":["Complexity"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2020\/5641596.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2020\/5641596.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2020\/5641596.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,12]],"date-time":"2020-10-12T19:50:24Z","timestamp":1602532224000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/complexity\/2020\/5641596\/"}},"subtitle":[],"editor":[{"given":"Jingang","family":"Lai","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,10,10]]},"references-count":21,"alternative-id":["5641596","5641596"],"URL":"https:\/\/doi.org\/10.1155\/2020\/5641596","relation":{},"ISSN":["1099-0526","1076-2787"],"issn-type":[{"type":"electronic","value":"1099-0526"},{"type":"print","value":"1076-2787"}],"subject":[],"published":{"date-parts":[[2020,10,10]]}}}