{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T02:07:46Z","timestamp":1740103666047,"version":"3.37.3"},"reference-count":21,"publisher":"Wiley","license":[{"start":{"date-parts":[[2020,12,21]],"date-time":"2020-12-21T00:00:00Z","timestamp":1608508800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013096","name":"Science and Technology Project of State Grid","doi-asserted-by":"publisher","award":["5216A520000M"],"award-info":[{"award-number":["5216A520000M"]}],"id":[{"id":"10.13039\/501100013096","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Complexity"],"published-print":{"date-parts":[[2020,12,21]]},"abstract":"<jats:p>With the rapid development of renewable generators such as distributed photovoltaic and profound changes of the power structure, this paper analyzes the frequency characteristics of the power system with high penetration of renewable generations in the process of low-frequency load shedding and discusses the influence of the distributed renewable generator frequency endurance capabilities on the implementation effect of low-frequency load shedding in detail. Finally, the influences of the distributed renewable generator frequency endurance capability and the capacities of the distributed renewable generator on frequency response characteristics of an actual Hunan power grid are simulated. The simulation results show that more distributed photovoltaic capacity without frequency endurance capability leads to deeper frequency drops after the disturbance and requires more basic rounds of load shedding. When the penetration rate of distributed photovoltaic is too high, it may cause load shedding, resulting in power grid load losses and, at the same time, leading to an overshoot phenomenon in the process of frequency recovery. Therefore, the influence of distributed photovoltaic on the control of low-frequency load shedding should be considered when designing low-frequency load shedding schemes for the power grid with high penetration of distributed photovoltaic.<\/jats:p>","DOI":"10.1155\/2020\/8899946","type":"journal-article","created":{"date-parts":[[2020,12,21]],"date-time":"2020-12-21T19:50:14Z","timestamp":1608580214000},"page":"1-9","source":"Crossref","is-referenced-by-count":1,"title":["Analysis of the Influence of Renewable Generator Frequency Endurance Capability on Low-Frequency Load Shedding: A Hunan Case Study"],"prefix":"10.1155","volume":"2020","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1658-0105","authenticated-orcid":true,"given":"Yang-Wu","family":"Shen","sequence":"first","affiliation":[{"name":"The State Grid Hunan Electric Power Company Limited Research Institute, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ding","family":"Wang","sequence":"additional","affiliation":[{"name":"The State Grid Hunan Electric Power Company Limited Research Institute, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Chen","sequence":"additional","affiliation":[{"name":"The State Grid Hunan Electric Power Company Limited, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Zuo","sequence":"additional","affiliation":[{"name":"The State Grid Hunan Electric Power Company Limited Research Institute, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min","family":"Xu","sequence":"additional","affiliation":[{"name":"The State Grid Hunan Electric Power Company Limited, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Cao","sequence":"additional","affiliation":[{"name":"The State Grid Hunan Electric Power Company Limited, Hunan, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"issue":"10","key":"1","first-page":"72","article-title":"Coordinated control of multi-HVDC participating in three defense line at the receiving end of the power system with strong DC and weak AC","volume":"51","author":"S. Yuan","year":"2018","journal-title":"Electric Power"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1109\/tec.2015.2449900"},{"issue":"11","key":"3","first-page":"3131","article-title":"Optimization of under frequency load shedding scheme based on improved systemfrequency response model","volume":"37","author":"G. Cai","year":"2013","journal-title":"Power System Technology"},{"issue":"4","key":"4","first-page":"95","article-title":"WAMS-based adaptive UFLS considering dynamic correction","volume":"34","author":"Z. Song","year":"2014","journal-title":"Electric Power Automation Equipment"},{"issue":"21","key":"5","first-page":"9","article-title":"Unstable modes evolution and its influencing factors analysis in interconnected power grids","volume":"37","author":"X. Ren","year":"2013","journal-title":"Automation of Electric Power Systems"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/7968914"},{"issue":"20","key":"7","first-page":"54","article-title":"Analysis of securing function and economic benefit of pumped storage station in power grid","volume":"28","author":"Y. He","year":"2004","journal-title":"Power System Technology"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1109\/tsg.2014.2349999"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1061\/(asce)ey.1943-7897.0000529"},{"issue":"12","key":"10","first-page":"3461","article-title":"An optimal algorithm of comprehensive cost for under-frequency loadshedding","volume":"37","author":"J. He","year":"2013","journal-title":"Power System Technology"},{"issue":"10","key":"11","first-page":"2861","article-title":"Research on coordination scheme for smart household appliances participating under frequency load shedding","volume":"37","author":"Yi Tang","year":"2013","journal-title":"Power System Technology"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1109\/tpwrs.2010.2059715"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1109\/tpwrs.2015.2395142"},{"issue":"3","key":"14","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1109\/TSG.2013.2259510","article-title":"Smart demand for frequency regulation experimental results","volume":"4","author":"P. J. Douglass","year":"2013","journal-title":"IEEE Transactions on Smart Grid"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1109\/tsg.2012.2192297"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1109\/tste.2015.2472299"},{"issue":"3","key":"17","first-page":"181","article-title":"Robust frequency control in a renewable penetrated power system: an adaptive fractional order-fuzzy approach","volume":"4","author":"A. Annamraju","year":"2019","journal-title":"Protection and Control of Modern Power Systems"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1186\/s41601-019-0144-2"},{"key":"19"},{"key":"20"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/4358958"}],"container-title":["Complexity"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2020\/8899946.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2020\/8899946.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2020\/8899946.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,21]],"date-time":"2020-12-21T19:50:33Z","timestamp":1608580233000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/complexity\/2020\/8899946\/"}},"subtitle":[],"editor":[{"given":"Qiang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,12,21]]},"references-count":21,"alternative-id":["8899946","8899946"],"URL":"https:\/\/doi.org\/10.1155\/2020\/8899946","relation":{},"ISSN":["1099-0526","1076-2787"],"issn-type":[{"type":"electronic","value":"1099-0526"},{"type":"print","value":"1076-2787"}],"subject":[],"published":{"date-parts":[[2020,12,21]]}}}