{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T07:48:24Z","timestamp":1767167304192,"version":"build-2238731810"},"reference-count":22,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2021,7,1]],"date-time":"2021-07-01T00:00:00Z","timestamp":1625097600000},"content-version":"vor","delay-in-days":181,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51908357"],"award-info":[{"award-number":["51908357"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100009019","name":"Shenzhen University","doi-asserted-by":"publisher","award":["000002110332"],"award-info":[{"award-number":["000002110332"]}],"id":[{"id":"10.13039\/501100009019","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Complexity"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:p>The poor fire resistance characteristic of super high\u2010rise curtain wall makes the curtain wall design one of the main approaches to improve its capacity for prevention and control over fire and smoke spread. The propagation of smoke leads to the increase in the temperature of the curtain wall on the upper and lower floors of the fire floor and consequently leads to glass fracture and other serious consequences. Current codes have control over fire resistance performance and size of fire partition materials but do not include requirements on the position of curtain walls on floors. By changing the position of fire partition in curtain walls, the paper carries out three comparative simulation experiments on two forms of fire partition: spandrel and fire prevention cornice. Besides, PyroSim is used to calculate the comparative simulation of fire and smoke spread and obtain the data on temperature variation nephogram and monitoring points in the center line of glass curtain walls during different fire scenarios, so as to discuss the influence of different positions of spandrels and fire canopy on fire hazard and smoke. This study finds out the following: fire canopy can better prevent the longitudinal spread of fire smoke than spandrels. The fire canopy above spandrels can reduce the flue\u2010gas temperature. The higher the spandrels above floors, the faster the temperature of the central lines of glass curtain walls above fire floors reduced. However, the higher the spandrels above floors, the more uneven the distributions of high\u2010temperature regions and low\u2010temperature regions, thus leading to the increase in horizontal temperature differences of glass panels. This research conclusion can be taken as a reference for fire protection design of super high\u2010rise glass curtain wall.<\/jats:p>","DOI":"10.1155\/2021\/4124049","type":"journal-article","created":{"date-parts":[[2021,7,1]],"date-time":"2021-07-01T13:37:51Z","timestamp":1625146671000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["[Retracted] Simulation Study on the Influence of Fire Partition on Curtain Wall Temperature in Super High\u2010Rise Buildings in China"],"prefix":"10.1155","volume":"2021","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5093-8633","authenticated-orcid":false,"given":"Tongtong","family":"Zhang","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7511-4262","authenticated-orcid":false,"given":"Di","family":"Cao","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2021,7]]},"reference":[{"key":"e_1_2_8_1_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.firesaf.2018.08.010"},{"key":"e_1_2_8_2_2","doi-asserted-by":"crossref","unstructured":"LuoY. XieY. ZhangJ. andWangP. Numerical simulation research on vertical fire spread control on the outside of super high-rise building Proceedings of the 2019 9th International Conference on Fire Science and Fire Protection Engineering (ICFSFPE) October 2019 Chengdu China https:\/\/doi.org\/10.1109\/ICFSFPE48751.2019.9055854.","DOI":"10.1109\/ICFSFPE48751.2019.9055854"},{"key":"e_1_2_8_3_2","article-title":"Fire characteristics and fire prevention difficulties of glass curtain wall","volume":"26","author":"Xin T.","year":"2016","journal-title":"Science and Technology"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2014.03.038"},{"key":"e_1_2_8_5_2","first-page":"126","article-title":"Design and research of interstory fire-fighting partition in super high-rise buildings","volume":"2019","author":"Yuan Q.","year":"2019","journal-title":"Architecture Technique"},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4613-9069-5"},{"key":"e_1_2_8_7_2","first-page":"4","article-title":"Sensitivity to input parameters of failure detection methods for out-of-plane loaded glass panels in fire","volume":"4","author":"Kozlowski M.","year":"2021","journal-title":"Fire-Switzerland"},{"key":"e_1_2_8_8_2","doi-asserted-by":"crossref","unstructured":"WangJ.-H. ChenJ.-J. GuoX.-J. andFengZ. Numerical simulation on the breakage of glass curtain in a tower building fire 2014 Proceedings of the 2014 7th International Conference on Intelligent Computation Technology and Automation October 2014 Changsha China no. 102 396\u2013399 https:\/\/doi.org\/10.1109\/ICICTA.2014.102 2-s2.0-84921748313.","DOI":"10.1109\/ICICTA.2014.102"},{"key":"e_1_2_8_9_2","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/2120570"},{"key":"e_1_2_8_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2016.10.045"},{"key":"e_1_2_8_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.engstruct.2013.02.002"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/stco.201410027"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2016.10.059"},{"key":"e_1_2_8_14_2","volume-title":"Code of Design on Building Fire Protection and Prevention","author":"National Standard of the People\u2019s Republic of China","year":"2018"},{"key":"e_1_2_8_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.firesaf.2017.10.001"},{"key":"e_1_2_8_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/fam.2527"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/fam.2914"},{"key":"e_1_2_8_18_2","unstructured":"ZhangT. \u201cThe research in optimization fire protection design of typical high-rise complex space in view of Performance-based design method\u201d 2016 Tianjin University Tianjin China Dissertation for a Ph.D."},{"key":"e_1_2_8_19_2","first-page":"316","article-title":"Influence of spandrel on fire spread in super high-rise buildings","volume":"37","author":"Ye C.","year":"2018","journal-title":"Fire Science and Technology"},{"key":"e_1_2_8_20_2","unstructured":"JensenR.andAssociates Inc. (Shanghai) Shanghai centre project fire special demonstration report Associates Inc. (Shanghai) Shanghai China."},{"key":"e_1_2_8_21_2","volume-title":"NFPA204M \u201cStandard of Smoke and Heat Venting\u201d","author":"National Fire Protection Association","year":"2002"},{"key":"e_1_2_8_22_2","article-title":"Technical specification for building smoke control","author":"DGJ","year":"2006","journal-title":"Code for Engineering Construction in Shanghai DGJ08-88-2006"}],"updated-by":[{"DOI":"10.1155\/2024\/9834056","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T00:00:00Z","timestamp":1706054400000},"record-id":"51717"},{"DOI":"10.1155\/2024\/9834056","type":"retraction","label":"Retraction","source":"publisher","updated":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T00:00:00Z","timestamp":1706054400000}}],"container-title":["Complexity"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2021\/4124049.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2021\/4124049.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2021\/4124049","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T19:15:55Z","timestamp":1723230955000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2021\/4124049"}},"subtitle":[],"editor":[{"given":"Zhihan","family":"Lv","sequence":"additional","affiliation":[]}],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.1155\/2021\/4124049"],"URL":"https:\/\/doi.org\/10.1155\/2021\/4124049","archive":["Portico"],"relation":{},"ISSN":["1076-2787","1099-0526"],"issn-type":[{"value":"1076-2787","type":"print"},{"value":"1099-0526","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"2021-04-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-06-04","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-07-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"4124049"}}