{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:00:54Z","timestamp":1753887654703,"version":"3.41.2"},"reference-count":25,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2021,6,18]],"date-time":"2021-06-18T00:00:00Z","timestamp":1623974400000},"content-version":"vor","delay-in-days":168,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100018543","name":"Natural Science Foundation of Tibet Autonomous Region","doi-asserted-by":"crossref","award":["XZ202001ZR0093G","2020D-ZN-01"],"award-info":[{"award-number":["XZ202001ZR0093G","2020D-ZN-01"]}],"id":[{"id":"10.13039\/501100018543","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Key Laboratory of Higher Education of Tibet Autonomous Region","award":["XZ202001ZR0093G","2020D-ZN-01"],"award-info":[{"award-number":["XZ202001ZR0093G","2020D-ZN-01"]}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Complexity"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:p>Photovoltaic (PV) power generation is the main aspect of new energy power generation, and it is an important means to achieve the goal of carbon neutrality. When the PV system is connected to the grid, the nonlinear load of the grid will affect the power quality and consume reactive power. This paper proposes a PV power generation grid\u2010connected system to improve power quality, with an active power filter (APF) function. Through the maximum power point tracking (MPPT) method, PV power generation can operate at the maximum power point and play the function of harmonic and reactive power compensation at the load side. To improve the dynamic performance of the grid\u2010connected PV system and harmonic compensation simultaneously, multistep finite control set model predictive control (FCS\u2010MPC) is adopted for the grid\u2010connected module. The whole system does not need additional equipment, as it plays the role of two devices and effectively reduces the input cost. In this paper, the proposed structure and multistep FCS\u2010MPC are verified in MATLAB\/Simulink. The results show that the system injects the maximum power into the power grid at the same time when the load changes and compensates the harmonic generated by the nonlinear load of the power grid so that the total harmonic distortion of the power grid can meet the operation standard, and the system has good dynamic performance and steady\u2010state performance.<\/jats:p>","DOI":"10.1155\/2021\/4249152","type":"journal-article","created":{"date-parts":[[2021,6,18]],"date-time":"2021-06-18T23:20:16Z","timestamp":1624058416000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Multistep Finite Control Set Model Predictive Control of Photovoltaic Power Generation System with Harmonic Compensation"],"prefix":"10.1155","volume":"2021","author":[{"given":"Xuejiao","family":"Gong","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4360-4739","authenticated-orcid":false,"given":"Shifeng","family":"Hu","sequence":"additional","affiliation":[]},{"given":"Ruijin","family":"Zhu","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2021,6,18]]},"reference":[{"key":"e_1_2_11_1_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2006.881997"},{"key":"e_1_2_11_2_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2006.878356"},{"key":"e_1_2_11_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2017.08.017"},{"key":"e_1_2_11_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2019.02.087"},{"key":"e_1_2_11_5_2","doi-asserted-by":"publisher","DOI":"10.17775\/CSEEJPES.2020.03590"},{"key":"e_1_2_11_6_2","doi-asserted-by":"publisher","DOI":"10.3390\/su13084094"},{"key":"e_1_2_11_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2006.874230"},{"key":"e_1_2_11_8_2","doi-asserted-by":"publisher","DOI":"10.3390\/en13082035"},{"key":"e_1_2_11_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/41.793345"},{"key":"e_1_2_11_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/28.556633"},{"key":"e_1_2_11_11_2","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2012.2221469"},{"key":"e_1_2_11_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2007.899854"},{"key":"e_1_2_11_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2229677"},{"key":"e_1_2_11_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2018.2815952"},{"key":"e_1_2_11_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2017.2714138"},{"key":"e_1_2_11_16_2","doi-asserted-by":"crossref","unstructured":"KimS. YooG. andSongJ. A bifunctional utility connected pho-tovoltaic system with power factor correction and UPS facility Proceedings of the Conference Record of the 25th IEEE Photovoltaic Specialists Conference(PVSC) May 1996 Washington DC USA IEEE 1363\u20131368 https:\/\/doi.org\/10.1109\/pvsc.1996.564386.","DOI":"10.1109\/PVSC.1996.564386"},{"key":"e_1_2_11_17_2","doi-asserted-by":"crossref","unstructured":"ChaudhariD. R.andGourS. PV-active power filter combination mitigating harmonics using FLC Proceedings of the 2017 Recent Developments in Control Automation & Power Engineering (RDCAPE) October 2017 Noida India IEEE 378\u2013381 https:\/\/doi.org\/10.1109\/RDCAPE.2017.8358300 2-s2.0-85048057239.","DOI":"10.1109\/RDCAPE.2017.8358300"},{"key":"e_1_2_11_18_2","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2018.2876619"},{"key":"e_1_2_11_19_2","doi-asserted-by":"crossref","unstructured":"FosterJ. G. L. PereiraR. R. GonzattiR. B. Sant\u2019AnaW. C. MollicaD. andLambert-TorresG. A review of FCS-MPC in multilevel converters applied to active power filters Proceedings of the 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern Power Electronics Conference (COBEP\/SPEC) December 2019 Santos Brazil 1\u20136 https:\/\/doi.org\/10.1109\/COBEP\/SPEC44138.2019.9065398.","DOI":"10.1109\/COBEP\/SPEC44138.2019.9065398"},{"key":"e_1_2_11_20_2","unstructured":"DavariS. A. KhaburiD. A. StolzeP. andKennelR. An improved finite control set-model predictive control (FCS-MPC) algorithm with imposed optimized weighting factor Proceedings of the 2011 14th European Conference on Power Electronics and Applications August 2011 Birmingham UK IEEE 1\u201310."},{"key":"e_1_2_11_21_2","doi-asserted-by":"crossref","unstructured":"Et-TaoussiM.andOuadiH. Power quality control for grid connected Photovoltaic system with Neutral Point Converter Proceedings of the 2016 International Renewable and Sustainable Energy Conference (IRSEC) November 2016 Marrakech Morocco IEEE https:\/\/doi.org\/10.1109\/irsec.2016.7983887 2-s2.0-85027860372.","DOI":"10.1109\/IRSEC.2016.7983887"},{"key":"e_1_2_11_22_2","doi-asserted-by":"publisher","DOI":"10.1080\/15325008.2016.1210698"},{"key":"e_1_2_11_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2019.2940891"},{"key":"e_1_2_11_24_2","doi-asserted-by":"crossref","unstructured":"ShirbhateA. S.andJawaleP. Power quality improvement in PV grid connected system by using active filter Proceedings of the International Conference on Energy Efficient Technologies for Sustainability April 2016 Nagercoil India IEEE https:\/\/doi.org\/10.1109\/iceets.2016.7583786 2-s2.0-84994096984.","DOI":"10.1109\/ICEETS.2016.7583786"},{"key":"e_1_2_11_25_2","doi-asserted-by":"crossref","unstructured":"ZongD. HuS. andYangX. Multi-step finite control set model predictive control for three-level APF Proceedings of the 5th International Workshop on Advances in Energy Science and Environment Engineering (AESEE 2021) April 2021 Xiamen China.","DOI":"10.1051\/e3sconf\/202125701087"}],"container-title":["Complexity"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2021\/4249152.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/complexity\/2021\/4249152.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2021\/4249152","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T21:29:36Z","timestamp":1723238976000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2021\/4249152"}},"subtitle":[],"editor":[{"given":"Chun","family":"Wei","sequence":"additional","affiliation":[]}],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.1155\/2021\/4249152"],"URL":"https:\/\/doi.org\/10.1155\/2021\/4249152","archive":["Portico"],"relation":{},"ISSN":["1076-2787","1099-0526"],"issn-type":[{"type":"print","value":"1076-2787"},{"type":"electronic","value":"1099-0526"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"2021-04-14","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-06-09","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-06-18","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"4249152"}}