{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T16:24:46Z","timestamp":1784132686595,"version":"3.55.0"},"reference-count":25,"publisher":"Wiley","license":[{"start":{"date-parts":[[2021,7,12]],"date-time":"2021-07-12T00:00:00Z","timestamp":1626048000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Mobile Information Systems"],"published-print":{"date-parts":[[2021,7,12]]},"abstract":"<jats:p>The stray current generated by subway running into the ground makes the main transformer in the urban area in a direct current (DC) bias state. First, the mathematical model of the metro stray current field is established and the Galerkin finite element method is applied to calculate the model. Then, the dynamic model of the stray current-induced geoelectric field under different working conditions is established by using ANSYS software, and the three-dimensional numerical simulation study of the stray current-induced geoelectric field of the subway is carried out. Finally, taking the Urumqi subway in Xinjiang as an example, the stray current-induced geoelectric field is calculated and simulated, and the correctness of the model is verified by comparing with the measured data of DC magnetic bias in the urban substation. The research can provide useful reference for the calculation and treatment of DC bias of the main transformer in the urban area under the action of stray current.<\/jats:p>","DOI":"10.1155\/2021\/4806136","type":"journal-article","created":{"date-parts":[[2021,7,12]],"date-time":"2021-07-12T23:05:07Z","timestamp":1626131107000},"page":"1-9","source":"Crossref","is-referenced-by-count":3,"title":["Calculation and Analysis of DC Magnetic Bias Current of Urban Main Transformer under the Action of Stray Current"],"prefix":"10.1155","volume":"2021","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7736-9525","authenticated-orcid":true,"given":"Weili","family":"Wu","sequence":"first","affiliation":[{"name":"School of Electrical and Control Engineering, Xi\u2019an University of Science & Technology, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenmei","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Electrical and Control Engineering, Xi\u2019an University of Science & Technology, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Li","sequence":"additional","affiliation":[{"name":"School of Electrical and Control Engineering, Xi\u2019an University of Science & Technology, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2015.2438853"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2011.2161345"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2015.2445913"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2013.2281191"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1109\/pesgm.2016.7741143"},{"issue":"7","key":"6","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1029\/2019SW002208","article-title":"Quantifying the performance of geomagnetically induced current models","volume":"17","author":"S. Marsal","year":"2019","journal-title":"Space Weather"},{"key":"7","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.3390\/en12091813","article-title":"Combination optimization configuration method of capacitance and resistance devices for suppressing DC bias in transformers","volume":"12","author":"D. Wang","year":"2019","journal-title":"Energies"},{"key":"8","volume-title":"Research on Stray Current of Urban Rail Transit","author":"Y. Pang","year":"2008"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1109\/tte.2020.2980745"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1002\/tee.23221"},{"issue":"4","key":"11","first-page":"860","article-title":"Theoretical derivation and numerical analysis for grounding computation of horizontal multi-layer soil","volume":"37","author":"Z. Pan","year":"2011","journal-title":"High Voltage Engineering"},{"issue":"12","key":"12","first-page":"4","article-title":"Network algorithm to analyze effects of DC transmission ground current on AC system","volume":"18","author":"Z. Ma","year":"2005","journal-title":"Guangdong Electric Power"},{"issue":"3","key":"13","first-page":"45","article-title":"Metro stray current distribution with current drainage net","volume":"29","author":"L. Mou","year":"2007","journal-title":"Journal of the China Railway Society"},{"key":"14","volume-title":"Research and Design of Stray Current Protection Scheme for DC Traction Power Supply System","author":"G. Xu","year":"2003"},{"issue":"4","key":"15","first-page":"571","article-title":"Mathematical model of distribution of metro stray current","volume":"26","author":"J. Wang","year":"2009","journal-title":"Chinese Journal of Engineering Mathematics"},{"issue":"6","key":"16","first-page":"44","article-title":"Simulation of subway stray current based on CDEGS","volume":"34","author":"K. Yu","year":"2014","journal-title":"Electric Railway"},{"issue":"4","key":"17","first-page":"67","article-title":"Evaluation and analysis of dynamic stray current in DC metro system","volume":"20","author":"D. Zhang","year":"2017","journal-title":"Urban Mass Transit"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1007\/s00521-019-04257-y"},{"key":"19","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/j.compeleceng.2017.12.022","article-title":"Self-maintenance model for wireless sensor networks","volume":"70","author":"W. Elsayed","year":"2018","journal-title":"Computers & Electrical Engineering"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1016\/j.compeleceng.2018.02.024"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2020.3014401"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2019.2895324"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1007\/s40820-020-00425-1"},{"issue":"11","key":"24","first-page":"3604","article-title":"Influence of the track-to-earth resistance of subway on stray current distribution","volume":"41","author":"L. Cai","year":"2015","journal-title":"High Voltage Engineering"},{"key":"25","volume-title":"Technical Specification for Stray Current Corrosion Protection of Metro","author":"CJJ 49-1992","year":"1992"}],"container-title":["Mobile Information Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/misy\/2021\/4806136.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/misy\/2021\/4806136.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/misy\/2021\/4806136.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,5]],"date-time":"2023-11-05T23:31:15Z","timestamp":1699227075000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/misy\/2021\/4806136\/"}},"subtitle":[],"editor":[{"given":"Sang-Bing","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2021,7,12]]},"references-count":25,"alternative-id":["4806136","4806136"],"URL":"https:\/\/doi.org\/10.1155\/2021\/4806136","relation":{},"ISSN":["1875-905X","1574-017X"],"issn-type":[{"value":"1875-905X","type":"electronic"},{"value":"1574-017X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,7,12]]}}}