{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T21:54:26Z","timestamp":1740174866801,"version":"3.37.3"},"reference-count":40,"publisher":"Wiley","license":[{"start":{"date-parts":[[2021,4,17]],"date-time":"2021-04-17T00:00:00Z","timestamp":1618617600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007620","name":"Department of Education of Liaoning Province","doi-asserted-by":"publisher","award":["JL-2015","2019JH8\/10100065","LGQN-1906"],"award-info":[{"award-number":["JL-2015","2019JH8\/10100065","LGQN-1906"]}],"id":[{"id":"10.13039\/501100007620","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Liaoning Province Science and Technology","award":["JL-2015","2019JH8\/10100065","LGQN-1906"],"award-info":[{"award-number":["JL-2015","2019JH8\/10100065","LGQN-1906"]}]},{"name":"Shenyang Institute of Engineering","award":["JL-2015","2019JH8\/10100065","LGQN-1906"],"award-info":[{"award-number":["JL-2015","2019JH8\/10100065","LGQN-1906"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Mobile Information Systems"],"published-print":{"date-parts":[[2021,4,17]]},"abstract":"<jats:p>This paper presents an active synchronous control scheme for distributed power grid connection based on the mobile network. This scheme avoids the disadvantages of the traditional control method, such as long waiting time and low reliability, and can meet the requirements of \u201cthe hotplug online\u201d distributed power grid connection. The scheme uses the mobile network to collect and detect voltage slip information between the distributed power system and large power grid before operation. When the voltage slip cannot meet the requirements of grid connection, the side voltage information of the distributed power system is actively regulated. The amplitude difference and phase difference signals are, respectively, adjusted by PI, and the generated adjustment signals are, respectively, sent to the corresponding controllers through the mobile network with different weight coefficients. After the receiver receives the regulated signal, it changes the amplitude and frequency of its output voltage by shifting the pendent characteristic curve, so as to realize the distributed power system side voltage and the large power grid side voltage eventually. Finally, simulation analysis and experiments are used to verify the effectiveness and practicability of the active synchronous control strategy.<\/jats:p>","DOI":"10.1155\/2021\/6683415","type":"journal-article","created":{"date-parts":[[2021,4,17]],"date-time":"2021-04-17T19:50:09Z","timestamp":1618689009000},"page":"1-14","source":"Crossref","is-referenced-by-count":0,"title":["Active Synchronous Control Strategy of Distributed Power Grid Connection Based on Mobile Network"],"prefix":"10.1155","volume":"2021","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5300-3158","authenticated-orcid":true,"given":"Liu","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Electrical Engineering, Shenyang University of Technology, Shenyang 110023, Liaoning, China"},{"name":"School of Electric Power, Shenyang Institute of Engineering, Shenyang 110036, Liaoning, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6335-5285","authenticated-orcid":true,"given":"Shaohua","family":"Ma","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Shenyang University of Technology, Shenyang 110023, Liaoning, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yangyang","family":"Ge","sequence":"additional","affiliation":[{"name":"Distribution Network TechnologyCenter, Liaoning Electric Power Research Institute, Shenyang 110023, Liaoning, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cailian","family":"Gu","sequence":"additional","affiliation":[{"name":"School of Electric Power, Shenyang Institute of Engineering, Shenyang 110036, Liaoning, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Renewable Energy, Shenyang Institute of Engineering, Shenyang 110036, Liaoning, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1109\/mpe.2018.2820445"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1109\/TITS,2983835"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1109\/TMC.2019.2914683"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1145\/3391198"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.4018\/ijom.2020100102"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1186\/s13638-019-1557-3"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/S1005-8885(16)60001-8"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1007\/s11036-020-01535-1"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1109\/mpe.2018.2864226"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1007\/s11036-019-01246-2"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2017.03.097"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2015.2427513"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.24840\/2183-0606_006-003_0004"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2016.2542519"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.06-0539-13"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1080\/23311975.2017.1353231"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1109\/tpwrd.2017.2682164"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2014.2364459"},{"issue":"12","key":"19","first-page":"23","article-title":"Design of optimal control system of \u2018source-grid-load-storage\u2019 based on 5G network","volume":"18","author":"H. Ren","year":"2020","journal-title":"Electric Power ICT"},{"issue":"7","key":"20","article-title":"Idea of random power supply plug and play based on cloud-layer-terminal three layer architecture","volume":"44","author":"R. Li","year":"2016","journal-title":"Power System Protection and Control"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2015.2397453"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2016.2539248"},{"issue":"8","key":"23","article-title":"A distribution network fault recovery studyon the dynamic alliance of mobile multi-agent","volume":"31","author":"L. Yang","year":"2016","journal-title":"Transactions of China Electrotechnical society"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2018.10.062"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1016\/j.renene.2018.10.031"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1007\/s13198-019-00891-w"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1007\/s40866-018-0052-y"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2015.2448112"},{"issue":"3","key":"29","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1007\/s11277-018-5789-z","article-title":"Secure self-healing group key distribution scheme with constant storage for SCADA systems in smart grid","volume":"101","author":"J. T. Tahadray","year":"2018","journal-title":"Wireless Personal Communications"},{"issue":"4","key":"30","first-page":"9","article-title":"A self-healing control method of smart distribution grid based on fault-tolerance","volume":"37","author":"H. B. Cheng","year":"2018","journal-title":"Advanced Technology of Electrical Engineering & Energy"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2018.2845695"},{"key":"32","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2017.2682164"},{"key":"33","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2017.2753838"},{"key":"34","doi-asserted-by":"publisher","DOI":"10.1109\/tii.2017.2662215"},{"key":"35","doi-asserted-by":"publisher","DOI":"10.1007\/s40565-018-0416-2"},{"key":"36","doi-asserted-by":"publisher","DOI":"10.1016\/j.eneco.2018.04.037"},{"key":"37","doi-asserted-by":"publisher","DOI":"10.1109\/tpwrd.2016.2522562"},{"key":"38","doi-asserted-by":"publisher","DOI":"10.1109\/jestpe.2016.2609391"},{"key":"39","doi-asserted-by":"publisher","DOI":"10.1109\/tpwrd.2017.2759302"},{"key":"40","doi-asserted-by":"publisher","DOI":"10.1109\/tec.2017.2661541"}],"container-title":["Mobile Information Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/misy\/2021\/6683415.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/misy\/2021\/6683415.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/misy\/2021\/6683415.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,17]],"date-time":"2021-04-17T19:50:19Z","timestamp":1618689019000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/misy\/2021\/6683415\/"}},"subtitle":[],"editor":[{"given":"Xiaoxian","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2021,4,17]]},"references-count":40,"alternative-id":["6683415","6683415"],"URL":"https:\/\/doi.org\/10.1155\/2021\/6683415","relation":{},"ISSN":["1875-905X","1574-017X"],"issn-type":[{"type":"electronic","value":"1875-905X"},{"type":"print","value":"1574-017X"}],"subject":[],"published":{"date-parts":[[2021,4,17]]}}}