{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T02:44:16Z","timestamp":1747190656080,"version":"3.40.5"},"reference-count":15,"publisher":"Wiley","license":[{"start":{"date-parts":[[2021,7,2]],"date-time":"2021-07-02T00:00:00Z","timestamp":1625184000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Intelligent Integrated Switch Based on High Voltage Capacitance Technology and Primary and Secondary Fusion in Distribution Network","award":["5230JY18000H"],"award-info":[{"award-number":["5230JY18000H"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Applied Mathematics"],"published-print":{"date-parts":[[2021,7,2]]},"abstract":"<jats:p>With the rapid development of the social economy, people\u2019s demand for energy is increasing. Global warming has made people pay more attention to the importance of energy saving and emission reduction. The power grid is the system responsible for the transmission and distribution of electric energy. Therefore, in the context of energy saving and emission reduction, there are higher requirements for substations in the power grid. For this reason, an intelligent switch with built-in electronic voltage transformer is designed. The concept and key technical characteristics of the electronic voltage transformer intelligent switch are introduced; the overall design scheme of the built-in electronic voltage transformer intelligent switch is expounded; the hardware and software system of the device is designed; the management and control strategy of the design device is such as transformer tangent control, voltage and reactive control; and the operating system is ported. Finally, the simulation test of the system proves that the system has high effectiveness and stability. The research can provide reference for the realization of efficient, economic, stable, safe, and environmentally friendly distribution of power in a power grid.<\/jats:p>","DOI":"10.1155\/2021\/8832812","type":"journal-article","created":{"date-parts":[[2021,7,2]],"date-time":"2021-07-02T22:37:08Z","timestamp":1625265428000},"page":"1-8","source":"Crossref","is-referenced-by-count":2,"title":["The Principle of Intelligent Switch Composition and Algorithm of the Built-In Electronic Voltage Transformer"],"prefix":"10.1155","volume":"2021","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4455-8850","authenticated-orcid":true,"given":"Xinhui","family":"Cao","sequence":"first","affiliation":[{"name":"State Grid Xinjiang Electric Power Co., Ltd., Economic and Technological Research Institute, 830002, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3686-8499","authenticated-orcid":true,"given":"Yuting","family":"Dong","sequence":"additional","affiliation":[{"name":"State Grid Xinjiang Electric Power Co., Ltd., Economic and Technological Research Institute, 830002, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3163-1126","authenticated-orcid":true,"given":"Zhongzheng","family":"Li","sequence":"additional","affiliation":[{"name":"State Grid Xinjiang Electric Power Co., Ltd., Economic and Technological Research Institute, 830002, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4801-2794","authenticated-orcid":true,"given":"Juan","family":"Li","sequence":"additional","affiliation":[{"name":"State Grid Xinjiang Electric Power Co., Ltd., Economic and Technological Research Institute, 830002, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0471-6976","authenticated-orcid":true,"given":"Gang","family":"Liang","sequence":"additional","affiliation":[{"name":"State Grid Xinjiang Electric Power Co., Ltd., Economic and Technological Research Institute, 830002, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6106-9429","authenticated-orcid":true,"given":"Honglian","family":"Zhou","sequence":"additional","affiliation":[{"name":"State Grid Xinjiang Electric Power Co., Ltd., Economic and Technological Research Institute, 830002, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"issue":"1","key":"1","first-page":"65","article-title":"Evaluation system of PMS current transformer equipment based on BP neural network","volume":"22","author":"X. Su","year":"2019","journal-title":"Electric Power Data"},{"issue":"19","key":"2","first-page":"203","article-title":"Application of electronic transformer in intelligent substation","volume":"553","author":"F. Zheng","year":"2018","journal-title":"Electronic World"},{"issue":"31","key":"3","first-page":"126","article-title":"Failure analysis of electronic current transformer in intelligent substation","volume":"251","author":"L. Liu","year":"2018","journal-title":"Science and Technology Innovation and Application"},{"issue":"11","key":"4","first-page":"12","article-title":"A misoperation analysis of the busbar protection caused by the switching of the energy supply of electronic transformers","volume":"59","author":"S. Chu","year":"2018","journal-title":"Electric World"},{"issue":"6","key":"5","first-page":"131","article-title":"Research on transient characteristics and testing technology of electronic voltage transformer based on digital physics hybrid simulation","volume":"47","author":"Y. Wang","year":"2019","journal-title":"Power System Protection and Control"},{"issue":"7","key":"6","first-page":"206","article-title":"Condition monitoring of voltage transformer based on L-M algorithm","volume":"48","author":"C. Tang","year":"2018","journal-title":"Mathematics in Practice and Theory"},{"issue":"177(3)","key":"7","first-page":"101","article-title":"Research and design of resistor-voltage-divided electronic voltage transformer","volume":"39","author":"G. Yang","year":"2018","journal-title":"Power Capacitor and Reactive Compensation"},{"volume-title":"Steady-State Calibration Method of Electronic Transformer Based on Improved Digital Filtering Algorithm","year":"2018","author":"Q. Gu","key":"8"},{"issue":"12","key":"9","first-page":"147","article-title":"Prediction of error state of electronic voltage transformer based on Q-ARMA","volume":"48","author":"Z. Li","year":"2018","journal-title":"Science in China"},{"volume-title":"Establishment of Harmonic Accuracy Test System for Electronic Voltage Transformer","year":"2018","author":"X. Liu","key":"10"},{"issue":"10","key":"11","first-page":"143","article-title":"Research and implementation of electronic transformer calibration system for alpine regions","volume":"54","author":"A. Mao","year":"2018","journal-title":"High Voltage Apparatus"},{"issue":"23","key":"12","article-title":"Research on fundamental phase synchronization algorithm based on electronic transformer","volume":"55","author":"T. Mou","year":"2017","journal-title":"Electric Measuring & Instrumentation"},{"volume-title":"Comparative Study of Resampling Synchronization Algorithms for all-Fiber Current Transformers","year":"2018","author":"J. Wang","key":"13"},{"key":"14","first-page":"136","article-title":"Improved high precision digital integration algorithm based on variable step size principle","volume":"2","author":"B. Tian","year":"2018","journal-title":"Automation of Electric Power System"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1109\/compel.2018.8460174"}],"container-title":["Journal of Applied Mathematics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/jam\/2021\/8832812.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jam\/2021\/8832812.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jam\/2021\/8832812.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,2]],"date-time":"2021-07-02T22:37:32Z","timestamp":1625265452000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/jam\/2021\/8832812\/"}},"subtitle":[],"editor":[{"given":"Qiankun","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2021,7,2]]},"references-count":15,"alternative-id":["8832812","8832812"],"URL":"https:\/\/doi.org\/10.1155\/2021\/8832812","relation":{},"ISSN":["1687-0042","1110-757X"],"issn-type":[{"type":"electronic","value":"1687-0042"},{"type":"print","value":"1110-757X"}],"subject":[],"published":{"date-parts":[[2021,7,2]]}}}