{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T10:47:34Z","timestamp":1770461254435,"version":"3.49.0"},"reference-count":31,"publisher":"Wiley","license":[{"start":{"date-parts":[[2021,3,21]],"date-time":"2021-03-21T00:00:00Z","timestamp":1616284800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100015507","name":"Shandong First Medical University","doi-asserted-by":"publisher","award":["161839"],"award-info":[{"award-number":["161839"]}],"id":[{"id":"10.13039\/501100015507","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Scanning"],"published-print":{"date-parts":[[2021,3,21]]},"abstract":"<jats:p>Intraoral scanners have been widely used in the application of dentistry. Accuracy includes trueness and precision; they have an important position in the assessment of intraoral scanners. The existing standard models are divided into the inlay and the crown, but the operation is relatively complicated. In this study, in order to simplify the current standard model, we designed a new integration model to compare the accuracy of two intraoral scanners (CEREC and TRIOS) and an extraoral scanner (SHINING). The coordinate measuring machine measured value is the gold standard. Values of the length and angle were analyzed by converting the scanned digital impressions into an STL (standard triangulation language) format to evaluate the accuracy of the intraoral scanner and to verify the feasibility of the designed model. The result shows that the integration model can be successfully scanned and imaged. In the case of the powder-free integration model, intraoral scanner precision, trueness, 3D fitting, and imaging are better than the extraoral scanner. It can be seen straightly from the measurement result and the 3D fitting result that the intraoral scanner can acquire the shape of the standard model integrally with good repeatability. Therefore, it can be concluded that TRIOS is superior to CEREC and SHINING in accuracy, and the integration model is feasible as a reference in the examination of intraoral scanners. The performance of the newly designed integration model that can be scanned is clinically significant, suggesting that this model can be used as a standard reference model.<\/jats:p>","DOI":"10.1155\/2021\/8891396","type":"journal-article","created":{"date-parts":[[2021,3,23]],"date-time":"2021-03-23T16:50:16Z","timestamp":1616518216000},"page":"1-8","source":"Crossref","is-referenced-by-count":6,"title":["Design of a Single-Tooth Model and Its Application in Oral Scan System Assessment"],"prefix":"10.1155","volume":"2021","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7281-229X","authenticated-orcid":true,"given":"HongXin","family":"Cai","sequence":"first","affiliation":[{"name":"Stomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai\u2019an, Shandong 271016, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bing Cheng","family":"Zhao","sequence":"additional","affiliation":[{"name":"Stomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai\u2019an, Shandong 271016, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yueyi","family":"Tian","sequence":"additional","affiliation":[{"name":"Stomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai\u2019an, Shandong 271016, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong-Hyuck","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul 08308, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunhan","family":"Sun","sequence":"additional","affiliation":[{"name":"Stomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai\u2019an, Shandong 271016, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ho-Kyung","family":"Lim","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul 08308, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1818-1140","authenticated-orcid":true,"given":"Eui-Seok","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul 08308, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2514-2633","authenticated-orcid":true,"given":"Heng Bo","family":"Jiang","sequence":"additional","affiliation":[{"name":"Stomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai\u2019an, Shandong 271016, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.4047\/jap.2018.10.1.58"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/1714642"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/1289570"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/4274715"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2016.07.021"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-013-1132-y"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1007\/s00056-016-0070-0"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.11.007"},{"issue":"2","key":"9","first-page":"151","article-title":"Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation","volume":"20","author":"J. Muallah","year":"2017","journal-title":"International Journal of Computerized Dentistry"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/8427595"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.37358\/MP.18.2.4988"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0158800"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2017.05.002"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/6545823"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2017.12.006"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-018-0489-3"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.11607\/ijp.4685"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1111\/jopr.12714"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2013.04.017"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.4012\/dmj.2017-208"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-017-0383-4"},{"key":"22","first-page":"177","article-title":"Optical impressions in the computer-assisted design and fabrication of dental crowns","volume":"23","author":"F. Duret","year":"1986","journal-title":"Le Journal Dentaire du Qu\u00e9bec"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2011.10.014"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.4012\/dmj.2016-326"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpor.2017.12.005"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1016\/j.optlaseng.2013.07.017"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.04.019"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1111\/ocr.12273"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.3390\/s19081924"},{"key":"30","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2015.12.018"},{"issue":"3A","key":"31","first-page":"533","article-title":"Design of an automated extraoral photogrammetry 3D scanner","volume":"16","author":"M. Alyaman","year":"2019","journal-title":"International Arab Journal of Information Technology"}],"container-title":["Scanning"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/scanning\/2021\/8891396.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/scanning\/2021\/8891396.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/scanning\/2021\/8891396.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,23]],"date-time":"2021-03-23T16:50:23Z","timestamp":1616518223000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/scanning\/2021\/8891396\/"}},"subtitle":[],"editor":[{"given":"Renato","family":"Buzio","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2021,3,21]]},"references-count":31,"alternative-id":["8891396","8891396"],"URL":"https:\/\/doi.org\/10.1155\/2021\/8891396","relation":{},"ISSN":["1932-8745","0161-0457"],"issn-type":[{"value":"1932-8745","type":"electronic"},{"value":"0161-0457","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3,21]]}}}