{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T08:17:28Z","timestamp":1767169048460,"version":"build-2238731810"},"reference-count":25,"publisher":"Wiley","license":[{"start":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T00:00:00Z","timestamp":1660780800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Evidence-Based Complementary and Alternative Medicine"],"published-print":{"date-parts":[[2022,8,18]]},"abstract":"<jats:p>\n                    Objective. After discussing the factors damaging hydrogen peroxide low-temperature plasma sterile packaging bags (hereinafter referred to as Tyvek packaging bags), the damage rate of Tyvek packaging bags is lowered through the control of link quality, so as to guarantee the quality of sterile packaging bags and the safety of patients. Methods. Design questionnaire and registration form by investigating 8606 instrument packaging bags sterilized by hydrogen peroxide low-temperature plasma from January 2019 to December 2019, the controllable factors damaging Tyvek packaging bags are analyzed from four aspects: instrument packaging, sterilization, transfer, and storage. By taking targeted interventions on 8155 instrument packaging bags sterilized from January 2020 to December 2020, the intervention effects of the key links and the damage rate are evaluated. Results. The main factors damaging Tyvek packaging bags mainly include improper transfer, storage, and management of instrument packing bags; improper use of instrument boxes; improper loading and uploading operations of sterilization; and the wrong size of packaging bags. For these factors, related intervention measures shall be adopted to control the link quality so as to lower the damage rate from 3.54% in the control group to 0.20% in the experimental group. The differences in damage rate are of statistical significance (\n                    <jats:inline-formula>\n                      <a:math xmlns:a=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M1\">\n                        <a:mi>P<\/a:mi>\n                        <a:mo>&lt;<\/a:mo>\n                        <a:mn>0.01<\/a:mn>\n                      <\/a:math>\n                    <\/jats:inline-formula>\n                    ). Conclusion. Tyvek packaging bags are influenced by controllable factors. Through reasonable link control and standard operations, the sterile packaging bags can be kept sterile from the end of sterilization to the usage by patients, which guarantees the safety of patients and is worthy of reference.\n                  <\/jats:p>","DOI":"10.1155\/2022\/4624912","type":"journal-article","created":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T18:20:10Z","timestamp":1660846810000},"page":"1-7","source":"Crossref","is-referenced-by-count":1,"title":["Research on the Factors Damaging Hydrogen Peroxide Low-Temperature Plasma Sterile Packaging Bags and the Control of Link Quality"],"prefix":"10.1155","volume":"2022","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5846-9096","authenticated-orcid":true,"given":"Yanfen","family":"Shen","sequence":"first","affiliation":[{"name":"Central Sterile Supply Department, The First Affiliated Hospital of Soochow University, Suzhou 215006, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Wu","sequence":"additional","affiliation":[{"name":"Central Sterile Supply Department, The First Affiliated Hospital of Soochow University, Suzhou 215006, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haijuan","family":"Sun","sequence":"additional","affiliation":[{"name":"Central Sterile Supply Department, The First Affiliated Hospital of Soochow University, Suzhou 215006, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shengao","family":"Wang","sequence":"additional","affiliation":[{"name":"Central Sterile Supply Department, The First Affiliated Hospital of Soochow University, Suzhou 215006, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"issue":"1","key":"1","first-page":"25","article-title":"Low-temperature hydrogen peroxide gas plasma\u2014atomic age sterilization technology","volume":"20","author":"C. Spry","year":"1998","journal-title":"Todays Surg Nurse"},{"issue":"29","key":"2","doi-asserted-by":"crossref","first-page":"624","DOI":"10.46234\/ccdcw2021.152","article-title":"Monitoring the effective sterilization of low-temperature hydrogen peroxide gas plasma sterilizers in 58 hospitals-22 PLADs, China, June 2015-December 2019","volume":"3","author":"J. Wang","year":"2021","journal-title":"China CDC weekly"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2016.04.247"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-80098-3"},{"key":"5","volume-title":"GB 27955-2020 Hygienic Requirements for Low-Temperature Hydrogen Peroxide Gas Plasma Sterilizer","author":"State Administration for Market Regulation","year":"2020"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1002\/pts.2293"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/s0001-2092(06)60198-1"},{"issue":"2","key":"8","first-page":"21","article-title":"Transport baskets and flexible sterilization packaging","volume":"20","author":"K. Engels","year":"2015","journal-title":"Med Device Decontamination"},{"issue":"24","key":"9","first-page":"6238","article-title":"Management of quality of sterilization with hydrogen peroxide low temperature plasma","volume":"24","author":"Z. M. Ding","year":"2014","journal-title":"Chinese Journal of Nosocomial"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1016\/j.aorn.2014.02.014"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1177\/0885328220967526"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1002\/marc.201900469"},{"issue":"15","key":"13","first-page":"1361","article-title":"Value of classified training program in sterile supple cancer","volume":"27","author":"H. Hao","year":"2012","journal-title":"Journal of Nurses Training"},{"issue":"1","key":"14","first-page":"55","article-title":"The clinical application status and development trends of hydrogen peroxide low temperature plasma sterilizers","volume":"40","author":"M. Zhuang","year":"2016","journal-title":"Chinese Journal of Medical Instrumentation"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.2165\/00003495-200565020-00003"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usab214"},{"key":"17","volume-title":"ANSI\/AAMI ST79: Comprehensive Guide to Steam Sterilization and Sterility Assurance in Health Care Facilities","author":"Association for the Advancement of Medical Instrumentation","year":"2010"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1016\/0195-6701(92)90136-a"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0100414"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0206892"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.3390\/mi12091020"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1016\/j.apergo.2018.12.010"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000027492"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1186\/s12913-019-4007-3"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1016\/s1553-7250(13)39014-x"}],"updated-by":[{"DOI":"10.1155\/2023\/9804757","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2023,6,21]],"date-time":"2023-06-21T00:00:00Z","timestamp":1687305600000},"record-id":"46073"},{"DOI":"10.1155\/2023\/9804757","type":"retraction","label":"Retraction","source":"publisher","updated":{"date-parts":[[2023,6,21]],"date-time":"2023-06-21T00:00:00Z","timestamp":1687305600000}}],"container-title":["Evidence-Based Complementary and Alternative Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/ecam\/2022\/4624912.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/ecam\/2022\/4624912.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/ecam\/2022\/4624912.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,18]],"date-time":"2022-08-18T18:20:19Z","timestamp":1660846819000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/ecam\/2022\/4624912\/"}},"subtitle":[],"editor":[{"given":"Shuli","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2022,8,18]]},"references-count":25,"alternative-id":["4624912","4624912"],"URL":"https:\/\/doi.org\/10.1155\/2022\/4624912","relation":{},"ISSN":["1741-4288","1741-427X"],"issn-type":[{"value":"1741-4288","type":"electronic"},{"value":"1741-427X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,8,18]]}}}