{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T05:12:00Z","timestamp":1784178720752,"version":"3.55.0"},"reference-count":12,"publisher":"Wiley","license":[{"start":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T00:00:00Z","timestamp":1646956800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Case Reports in Surgery"],"published-print":{"date-parts":[[2022,3,11]]},"abstract":"<jats:p>Bowel perforation associated with inserted peritoneal dialysis (PD) catheter mainly occurs during the perioperative period. Delayed bowel perforation is difficult to diagnose because of its different clinical signs and rarity. A 53-year-old woman developed acute abdomen after her PD catheter was changed. It was found that the changed catheter perforated the sigmoid colon. Primary repair of the perforated area of the sigmoid colon was performed, and the last inserted PD catheter was removed. The postoperative period and recovery were uneventful. Perforations due to the PD catheter may remain silent until the catheter is replaced. In patients with frequent episodes of peritonitis, a perforation area due to PD catheter which limited itself should be considered as the etiology.<\/jats:p>","DOI":"10.1155\/2022\/5443787","type":"journal-article","created":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T20:35:07Z","timestamp":1647030907000},"page":"1-3","source":"Crossref","is-referenced-by-count":1,"title":["Migration of Tenckhoff Catheter to Sigmoid Colon: A Rare Delayed Complication"],"prefix":"10.1155","volume":"2022","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1305-2056","authenticated-orcid":true,"given":"U\u011fur","family":"Topal","sequence":"first","affiliation":[{"name":"Department of General Surgery, Cukurova University Faculty of Medicine, 01330 Cukurova\/Adana, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5180-1543","authenticated-orcid":true,"given":"Abdullah","family":"\u00dclk\u00fc","sequence":"additional","affiliation":[{"name":"Department of General Surgery, Cukurova University Faculty of Medicine, 01330 Cukurova\/Adana, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2715-6390","authenticated-orcid":true,"given":"Ahmet G\u00f6khan","family":"Sar\u0131ta\u015f","sequence":"additional","affiliation":[{"name":"Department of General Surgery, Cukurova University Faculty of Medicine, 01330 Cukurova\/Adana, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7525-3107","authenticated-orcid":true,"given":"Atilgan Tolga","family":"Ak\u00e7am","sequence":"additional","affiliation":[{"name":"Department of General Surgery, Cukurova University Faculty of Medicine, 01330 Cukurova\/Adana, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5775-8953","authenticated-orcid":true,"given":"Ay\u015fe Gizem","family":"\u00dcnal","sequence":"additional","affiliation":[{"name":"Department of General Surgery, Cukurova University Faculty of Medicine, 01330 Cukurova\/Adana, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1560-7740","authenticated-orcid":true,"given":"\u0130smail Cem","family":"Eray","sequence":"additional","affiliation":[{"name":"Department of General Surgery, Cukurova University Faculty of Medicine, 01330 Cukurova\/Adana, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","reference":[{"issue":"3","key":"1","first-page":"43","article-title":"Compar\u0131ng catheter placement techn\u0131ques by compl\u0131cat\u0131ons and d\u0131aly\u0131s eff\u0131cacy \u0131n per\u0131toneal d\u0131alys\u0131s","volume":"74","author":"B. E. G\u00fcll\u00fc","year":"2011","journal-title":"Journal of Istanbul Faculty of Medicine"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1038\/nrneph.2016.181"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1007\/s13730-017-0258-1"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/697608"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.4103\/ijn.IJN_268_16"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.5262\/tndt.2010.1001.03"},{"issue":"2","key":"7","first-page":"124","article-title":"Mechanical complications in chronic peritoneal dialysis","volume":"52","author":"M. Moreiras Plaza","year":"1999","journal-title":"Clinical Nephrology"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1097\/00002216-199101000-00005"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1159\/000189316"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1186\/s41100-019-0219-6"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.12809\/hkmj144419"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.3747\/pdi.2012.00345"}],"container-title":["Case Reports in Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cris\/2022\/5443787.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cris\/2022\/5443787.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cris\/2022\/5443787.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T20:35:12Z","timestamp":1647030912000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/cris\/2022\/5443787\/"}},"subtitle":[],"editor":[{"given":"Giovanni","family":"Mariscalco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2022,3,11]]},"references-count":12,"alternative-id":["5443787","5443787"],"URL":"https:\/\/doi.org\/10.1155\/2022\/5443787","relation":{},"ISSN":["2090-6919","2090-6900"],"issn-type":[{"value":"2090-6919","type":"electronic"},{"value":"2090-6900","type":"print"}],"subject":[],"published":{"date-parts":[[2022,3,11]]}}}