{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T01:28:00Z","timestamp":1772069280271,"version":"3.50.1"},"reference-count":16,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2022,7,20]],"date-time":"2022-07-20T00:00:00Z","timestamp":1658275200000},"content-version":"vor","delay-in-days":200,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Contrast Media &amp; Molecular Imaging"],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:p>Tracheal intubation is an important access to general anesthesia surgery or respiratory support in critically ill patients. Orotracheal intubation is the most common method of establishing artificial airways in clinical practice. Tracheal intubation and mechanically assisted breathing are among the important steps in the clinical rescue of critically ill patients. During tracheal intubation, it easily causes iatrogenic skin damage, unclear mouth, ulcer, and other oral mucosal complications due to the improper fixation method and excellent dental pads. Therefore, the purpose of this study was to design a novel oral suction device for patients with orotracheal intubation and explore its safety, convenience, and comfort in the clinical application of orotracheal intubation patients. From October 2016 to April 2017, a total of 232 patients with mechanical ventilation through orotracheal intubation in the Department of Surgery and Critical Care Medicine were selected by the convenience sampling method. According to the random number table method, 232 cases were divided into the experimental group and control group, with 116 cases in each group. The experimental group used a self\u2010designed oral fluid suction device to fix the tracheal intubation; the control group used the traditional method, placing ordinary disposable tooth pads, and then using 3M tape to fix the tracheal intubation. The incidence of oral mucosa and lip pressure ulcers, patient comfort, and tracheal tube displacement were observed and compared between the two groups. The incidence of oral mucosa and lip pressure ulcers in the observation group using the self\u2010designed oral fluid suction device to fix the tracheal intubation was significantly lower than that in the control group. At the same time, the comfort of the patients was significantly higher than that of the control group, the incidence of tracheal tube displacement was significantly lower than that of the control group, and the differences between the above indicators were statistically significant (<jats:italic>P<\/jats:italic> &lt; 0.05). For patients with orotracheal intubation, using a new oral fluid suction device to fix the tracheal intubation can effectively prevent the displacement of the tracheal intubation, protect the oral mucosa and lips, and reduce the pain of the patient. At the same time, the oral fluid suction device designed in this study has low production cost, strong practicability, and is suitable for clinical promotion.<\/jats:p>","DOI":"10.1155\/2022\/6057115","type":"journal-article","created":{"date-parts":[[2022,7,20]],"date-time":"2022-07-20T18:50:19Z","timestamp":1658343019000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Design and Clinical Application Effect Analysis of a New Type of Oral Fluid Suction Device for Patients with Orotracheal Intubation"],"prefix":"10.1155","volume":"2022","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8488-109X","authenticated-orcid":false,"given":"Yanying","family":"Qian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haifei","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,7,20]]},"reference":[{"key":"e_1_2_9_1_2","first-page":"580","article-title":"Application of portable fiberoptic bronchoscope-guided nasotracheal intubation in the rescue of patients with respiratory failure[J]","volume":"41","author":"Li X.","year":"2020","journal-title":"Guangdong Medical Journal"},{"key":"e_1_2_9_2_2","first-page":"31","article-title":"Observation on the effect of improved method for preventing oral pressure ulcers in patients with oral tracheal intubation[J]","volume":"30","author":"Wang X.","year":"2011","journal-title":"Inner Mongolia Journal of Traditional Chinese Medicine"},{"key":"e_1_2_9_3_2","first-page":"185","article-title":"Design and application of dental pad protective cover for orotracheal intubation [J]","volume":"7","author":"Mi Y.","year":"2015","journal-title":"China Clinical Nursing"},{"key":"e_1_2_9_4_2","first-page":"1360","article-title":"Analysis of the causes and countermeasures of oral and cervical pressure ulcers in patients with endotracheal intubation [J]","volume":"27","author":"Kong J.","year":"2013","journal-title":"Chinese Nursing Research"},{"key":"e_1_2_9_5_2","article-title":"Application of syringe in fixation of orotracheal intubation [J]","volume":"2","author":"Li Y.","year":"2009","journal-title":"Chinese Critical Care Medicine"},{"key":"e_1_2_9_6_2","first-page":"101","article-title":"Improved tracheal tube fixation for preventing tracheal tube detachment during craniocerebral surgery[J]","volume":"31","author":"Zhang Z.","year":"2010","journal-title":"Jilin Medical Journal"},{"key":"e_1_2_9_7_2","first-page":"74","article-title":"The effect of improved tooth pads in the prevention of oral pressure ulcers in ICU patients with endotracheal intubation [J]","volume":"33","author":"Mi Y.","year":"2016","journal-title":"Nursing Journal of Chinese People\u2019s Liberation Army"},{"key":"e_1_2_9_8_2","first-page":"1448","article-title":"Application and effect observation of self-locking endotracheal intubation fixator in ICU [J ]","volume":"24","author":"Yan D.","year":"2014","journal-title":"China Health Care & Nutrition"},{"key":"e_1_2_9_9_2","first-page":"115","article-title":"Observation on the effect of improved orotracheal tube fixation on patients with restlessness [J]","volume":"13","author":"Huang L.","year":"2016","journal-title":"Nursing Practice and Research"},{"key":"e_1_2_9_10_2","first-page":"83","article-title":"Lengqian Effect of modified reinforced mask on oxygen inhalation after tracheal intubation removal in stroke patients in ICU [J]","volume":"37","author":"Wang S.","year":"2022","journal-title":"Journal of Nursing Education"},{"key":"e_1_2_9_11_2","first-page":"620","article-title":"Research progress on the fixation method of adult oral endotracheal intubation [J]","volume":"33","author":"Fan H.","year":"2019","journal-title":"Chinese Nursing Research"},{"key":"e_1_2_9_12_2","first-page":"134","article-title":"Observation on the application of two fixation methods in oral endotracheal intubation [J]","volume":"7","author":"Feng G.","year":"2017","journal-title":"China Medicine and Pharmacy"},{"key":"e_1_2_9_13_2","first-page":"160","article-title":"The effect of different oral cleaners on preventing pulmonary infection in stroke patients with dysphagia [J]","volume":"33","author":"Fang M.","year":"2011","journal-title":"Fujian Medical Journal"},{"key":"e_1_2_9_14_2","first-page":"2291","article-title":"Research on skin damage caused by orotracheal intubation to fix the dental pad[J]","volume":"31","author":"Miao G.","year":"2016","journal-title":"Journal of Nurses Training"},{"key":"e_1_2_9_15_2","first-page":"27","article-title":"Analysis and management of high risk factors in patients with accidental extubation of ICU mechanical ventilation [J]","volume":"12","author":"Zhang X.","year":"2015","journal-title":"Nursing Practice and Research"},{"key":"e_1_2_9_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-013-2249-5"}],"container-title":["Contrast Media &amp; Molecular Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmi\/2022\/6057115.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmi\/2022\/6057115.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2022\/6057115","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T06:40:40Z","timestamp":1721803240000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2022\/6057115"}},"subtitle":[],"editor":[{"given":"Mohammad Farukh","family":"Hashmi","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,1]]}},"alternative-id":["10.1155\/2022\/6057115"],"URL":"https:\/\/doi.org\/10.1155\/2022\/6057115","archive":["Portico"],"relation":{},"ISSN":["1555-4309","1555-4317"],"issn-type":[{"value":"1555-4309","type":"print"},{"value":"1555-4317","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1]]},"assertion":[{"value":"2022-05-09","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-06-09","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"6057115"}}