{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T13:57:38Z","timestamp":1789567058873,"version":"build-2803163510"},"reference-count":33,"publisher":"Wiley","license":[{"start":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T00:00:00Z","timestamp":1649635200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computational and Mathematical Methods in Medicine"],"published-print":{"date-parts":[[2022,4,11]]},"abstract":"<jats:p>Objective. Image segmentation technology is applied to separate a single vertebra from the three-dimensional model of the spine, so as to separate a single vertebra image with smaller error, higher degree of automation, and better results. The objectives are to study the biomechanical characteristics of posterior short-segment pedicle screw fixation by three-dimensional finite element method, analyze the mechanical characteristics of posterior pedicle screw rod fixation system under different factors, and demonstrate the feasibility of its application in the treatment of lumbar fracture. Methods. The authors searched the database for articles about the treatment of lumbar spine fracture, screw rod internal fixation system, and its mechanical parameters. The threshold segmentation method based on region segmentation method was used to segment the image, and the three-dimensional finite element model was used to analyze the biomechanical characteristics of different posterior internal fixation for lumbar spine fracture. Results. The posterior pedicle internal fixation system for the treatment of multilevel spinal fractures is a mature surgical technique and has fewer postoperative complications. Transpedicle fixation is effective and reliable. It can effectively restore the coronal and sagittal curvature of the vertebral body and restore the stability of the spine better. But the choice of internal fixation method should be individualized based on fracture type, identification of critical and secondary injury sites, and stability assessment. Only after mastering the biomechanical characteristics of the posterior screw rod system for the treatment of lumbar fracture, selecting the appropriate method, and fixing the appropriate movement unit can the best fixation be achieved. Conclusion. Threshold method is the most direct and simple image segmentation method. The core technology of thresholding is the selection of threshold, which will affect the final segmentation effect. The most common segmentation method is to calculate the segmentation threshold by histogram. The threshold method has less computation and good segmentation effect for the image with large contrast between background and target. Posterior pedicle screw rod system internal fixation has the advantages of less trauma, good reduction, reliable fixation, and less complications. The design, placement angle and depth of various internal fixation systems, and the number of fixed segments all show different mechanical characteristics. As long as we master the above characteristics, choose the appropriate method and fix the appropriate motor unit, and we can get the best fixation; it can be used as an effective treatment for lumbar fracture.<\/jats:p>","DOI":"10.1155\/2022\/6497754","type":"journal-article","created":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T23:05:12Z","timestamp":1649718312000},"page":"1-10","source":"Crossref","is-referenced-by-count":11,"title":["Mechanical Analysis of Posterior Pedicle Screw System Placement and Internal Fixation in the Treatment of Lumbar Fractures"],"prefix":"10.1155","volume":"2022","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3053-9931","authenticated-orcid":true,"given":"Shengkai","family":"Mu","sequence":"first","affiliation":[{"name":"Shenyang Orthopedic Hospital, Shenyang, Liaoning 110044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingxu","family":"Wang","sequence":"additional","affiliation":[{"name":"Shenyang Orthopedic Hospital, Shenyang, Liaoning 110044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuyi","family":"Gong","sequence":"additional","affiliation":[{"name":"Shenyang Orthopedic Hospital, Shenyang, Liaoning 110044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2012.12.005"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-197803000-00003"},{"issue":"7","key":"3","first-page":"277","article-title":"Finite element stress analysisof an intervertebral disc","volume":"974","author":"T. Belytschko","year":"1992","journal-title":"Journal of Biomechanics"},{"issue":"2","key":"4","first-page":"135","article-title":"The optimal elementsize, material property distributions and modeling methodsfor finite element modeling of lumbar vertebra","volume":"31","author":"K. J. Cai","year":"2016","journal-title":"Journal of Medical Biomechanics"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-008-9151-y"},{"key":"6","first-page":"69","article-title":"A modified particle swarm optimizer","author":"Y. Shi"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/j.future.2020.11.001"},{"key":"8","first-page":"84","article-title":"Comparing inertia weights and constrictionfactors in particle swarm optimization","author":"R. C. Eberhart"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000182319.81795.72"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000061987.71624.17"},{"issue":"3","key":"11","first-page":"193","article-title":"Biomechanical finite elementanalysis of bone graft fusion of bilateral articular processcombined with spinous process preventing postoperativecorrection loss for thoracolumbar fracture surgery","volume":"24","author":"D. W. He","year":"2009","journal-title":"Yiyong Shengwu Lixue\/Journal of Medical Biomechanics"},{"issue":"3","key":"12","first-page":"200","article-title":"Establishing finite ele-ment contact model of human L1 ~ L5 lumbar segments","volume":"25","author":"J. Su","year":"2010","journal-title":"Journal of Medical Biomechanics"},{"key":"13","first-page":"1268","article-title":"Relationshipbetweentrau-maticspinalcancalstenosisandneurologicdeficitsinthoracolum-barburstfractures","volume":"13","author":"T. Hashimoto","year":"1988","journal-title":"Spine"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198870080-00009"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199318040-00016"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199509150-00003"},{"issue":"2","key":"17","first-page":"161","article-title":"Biomechanical Evaluation of Anterior Thoracolumbar Spinal Instrumentation[J]","volume":"2","author":"J. W. You","year":"1995","journal-title":"Journal of Korean Society of Spine Surgery"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199610010-00009"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199707150-00007"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199108001-00024"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200001150-00006"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2010.10.021"},{"issue":"9","key":"23","first-page":"1157","article-title":"Successfulshort-seg-mentinstrumentationandfusionforthoracolumbarspinalfrac-tures: aconsecutive 4\u22195-yearstudy","volume":"25","author":"J. W. Parker","year":"2000","journal-title":"Spine"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.3171\/spi.2006.5.2.117"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1016\/S1529-9430(01)00101-2"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000116990.31984.A9"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1016\/j.vacuum.2021.110460"},{"issue":"3","key":"28","first-page":"355","article-title":"Dispersion of waves characteristics of laminated composite nanoplate","volume":"40","author":"X. Xu","year":"2021","journal-title":"Steel and Composite Structures"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.1016\/j.energy.2019.06.051"},{"key":"30","article-title":"Nonlinear tribo-dynamic model and experimental verification of a spur gear drive under loss-of-lubrication condition","volume":"153, article 107509","author":"H. Bo","year":"2021","journal-title":"Mechanical Systems and Signal Processing"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-012-1076-y"},{"key":"32","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e318192d8ad"},{"issue":"12, article 105059","key":"33","article-title":"Super-resolution reconstruction of knee magnetic resonance imaging based on deep learning","volume":"187","author":"D. Qiu","year":"2019","journal-title":"Computer Methods and Programs in Biomedicine"}],"container-title":["Computational and Mathematical Methods in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2022\/6497754.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2022\/6497754.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/cmmm\/2022\/6497754.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T23:05:19Z","timestamp":1649718319000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/cmmm\/2022\/6497754\/"}},"subtitle":[],"editor":[{"given":"Kelvin","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2022,4,11]]},"references-count":33,"alternative-id":["6497754","6497754"],"URL":"https:\/\/doi.org\/10.1155\/2022\/6497754","relation":{},"ISSN":["1748-6718","1748-670X"],"issn-type":[{"value":"1748-6718","type":"electronic"},{"value":"1748-670X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4,11]]}}}