{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T20:54:43Z","timestamp":1775595283744,"version":"3.50.1"},"reference-count":30,"publisher":"Wiley","license":[{"start":{"date-parts":[[2022,11,19]],"date-time":"2022-11-19T00:00:00Z","timestamp":1668816000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Thammasat University Research Fund"},{"name":"SIIT Research Fund"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Healthcare Engineering"],"published-print":{"date-parts":[[2022,11,19]]},"abstract":"<jats:p>Diabetic retinopathy is an eye-related pathology creating abnormalities and causing visual impairment, proper treatment of which requires identifying irregularities. This research uses a hemorrhage detection method and compares the classification of conventional and deep features. Especially, the method identifies hemorrhage connected with blood vessels or residing at the retinal border and was reported challenging. Initially, adaptive brightness adjustment and contrast enhancement rectify degraded images. Prospective locations of hemorrhages are estimated by a Gaussian matched filter, entropy thresholding, and morphological operation. Hemorrhages are segmented by a novel technique based on the regional variance of intensities. Features are then extracted by conventional methods and deep models for training support vector machines and the results are evaluated. Evaluation metrics for each model are promising, but findings suggest that comparatively, deep models are more effective than conventional features.<\/jats:p>","DOI":"10.1155\/2022\/7387174","type":"journal-article","created":{"date-parts":[[2022,11,19]],"date-time":"2022-11-19T17:05:13Z","timestamp":1668877513000},"page":"1-9","source":"Crossref","is-referenced-by-count":4,"title":["Comparing Conventional and Deep Feature Models for Classifying Fundus Photography of Hemorrhages"],"prefix":"10.1155","volume":"2022","author":[{"given":"Tamoor","family":"Aziz","sequence":"first","affiliation":[{"name":"School of Information, Computer and Communication Technology, Sirindhorn International Institute of Technology, Thammasat University, Pathum-Thani, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1705-4411","authenticated-orcid":true,"given":"Chalie","family":"Charoenlarpnopparut","sequence":"additional","affiliation":[{"name":"School of Information, Computer and Communication Technology, Sirindhorn International Institute of Technology, Thammasat University, Pathum-Thani, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Srijidtra","family":"Mahapakulchai","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Kasetsart University, Bangkok, Thailand"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1111\/ceo.12696"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-81539-3"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.2337\/dc13-1507"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/8234186"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.4239\/wjd.v7.i16.333"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2015.08.008"},{"issue":"2","key":"7","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1109\/TMI.2012.2227119","article-title":"Splat feature classification with application to retinal hemorrhage detection in fundus images","volume":"32","author":"L. Tang","year":"2012","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.5121\/ijcsit.2013.5502"},{"key":"9","first-page":"399","article-title":"Automatic hemorrhage detection in color fundus images based on gradual removal of vascular branches","author":"L. Zhou"},{"issue":"6","key":"10","first-page":"1","article-title":"Distinguising proof of diabetic retinopathy detection by hybrid approaches in two dimensional retinal fundus images","volume":"43","author":"S. Karkuzhali","year":"2019","journal-title":"Journal of Medical Systems"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ins.2017.08.050"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.17-22721"},{"key":"13","article-title":"Deep learning based early detection and grading of diabetic retinopathy using retinal fundus images","author":"S. M. S. Islam","year":"2018"},{"key":"14","first-page":"49","article-title":"Detection of red lesions in retinal fundus images using YOLO V3","volume":"7","author":"P. Pal","year":"2020","journal-title":"Curr. Indian Eye Res. J. Ophthalmic Res. Group"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/j.patrec.2020.02.026"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2022.103536"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-021-00447-0"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.3390\/app11146391"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-11739-8_6"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijleo.2019.02.054"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1109\/42.34715"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1016\/j.compeleceng.2011.06.006"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvcir.2016.10.013"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1109\/ICIMTech.2019.8843844"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.1007\/s42979-020-0114-9"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocs.2018.11.008"},{"key":"27","first-page":"267","article-title":"Document image dataset indexing and compression using connected components clustering","author":"H. Chatbri"},{"key":"28","article-title":"A GLCM embedded CNN strategy for computer-aided diagnosis in intracerebral hemorrhage","author":"Y. Hu","year":"2019"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.2478\/cait-2013-0009"},{"key":"30","doi-asserted-by":"publisher","DOI":"10.1016\/j.compeleceng.2018.07.042"}],"container-title":["Journal of Healthcare Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/jhe\/2022\/7387174.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jhe\/2022\/7387174.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jhe\/2022\/7387174.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,19]],"date-time":"2022-11-19T17:05:24Z","timestamp":1668877524000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/jhe\/2022\/7387174\/"}},"subtitle":[],"editor":[{"given":"Huiying","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2022,11,19]]},"references-count":30,"alternative-id":["7387174","7387174"],"URL":"https:\/\/doi.org\/10.1155\/2022\/7387174","relation":{},"ISSN":["2040-2309","2040-2295"],"issn-type":[{"value":"2040-2309","type":"electronic"},{"value":"2040-2295","type":"print"}],"subject":[],"published":{"date-parts":[[2022,11,19]]}}}