{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T00:01:46Z","timestamp":1767830506487,"version":"3.49.0"},"reference-count":29,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2022,3,20]],"date-time":"2022-03-20T00:00:00Z","timestamp":1647734400000},"content-version":"vor","delay-in-days":78,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100011324","name":"Qingdao University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100011324","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Clinical Practice"],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:p><jats:italic>Objective<\/jats:italic>. The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS\u2010OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis. <jats:italic>Methods<\/jats:italic>. This prospective study included 102 patients (102 eyes) scheduled for simple cataract surgery. Among the total patients, 44 were men, and 58 were women. AS\u2010OCT (sitting) and UBM (lying) were used to measure the anterior chamber depth (ACD) in horizontal and vertical orientations and the iris\u2010lens contact distance (ILCD) and iris\u2010lens angle (ILA) in inferior, superior, nasal, and temporal quadrants. Paired\u2010sample <jats:italic>t<\/jats:italic>\u2010test was used to compare ACD, ILCD, and ILA measurements of the two methods, while Pearson\u2019s linear correlation and Bland\u2010Altman analyses were used to analyze the correlation and consistency of the two results. <jats:italic>Results<\/jats:italic>. The horizontal (2.499\u2009\u00b1\u20090.464\u2009mm) and vertical (2.531\u2009\u00b1\u20090.463\u2009mm) ACD measured using AS\u2010OCT and the horizontal (2.556\u2009\u00b1\u20090.467\u2009mm) and vertical (2.563\u2009\u00b1\u20090.479\u2009mm) ACD measured using UBM were significantly different (<jats:italic>P<\/jats:italic> &lt; 0.001); moreover, the results showed good correlation and agreement. A significant difference was observed between the two methods in terms of ILCD measured in inferior, superior, nasal, and temporal quadrants (<jats:italic>P<\/jats:italic> &lt; 0.001), and a significant correlation was found between measurements of both methods (<jats:italic>P<\/jats:italic> &lt; 0.001). Approximately 3.92% (4\/102), 0.98% (1\/102), 3.92% (4\/102), and 2.94% (3\/102) of points were outside the 95% limits of agreement in the four quadrants, respectively, and the agreement of the results was good. ILA measured using both methods differed in inferior, superior, nasal, and temporal quadrants (<jats:italic>P<\/jats:italic> = 0.003, 0.011, 0.001, 0.001, respectively), and the correlation was good (<jats:italic>P<\/jats:italic> &lt; 0.001). The percentage of points outside the 95% limit was higher in inferior, superior, nasal, and temporal quadrants (4.90% (5\/102), 5.88% (6\/102), 5.88% (6\/102), and 6.86% (7\/102)) with poor agreement of the results. <jats:italic>Conclusions<\/jats:italic>. The correlation between AS\u2010OCT and UBM in terms of measuring lens position\u2010related parameters was good, but the agreement was unstable. The differences in measurement position (sitting and supine) and\/or measurement methods (optics and ultrasound) may lead to variability in results.<\/jats:p>","DOI":"10.1155\/2022\/7599631","type":"journal-article","created":{"date-parts":[[2022,3,20]],"date-time":"2022-03-20T23:16:55Z","timestamp":1647818215000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy"],"prefix":"10.1155","volume":"2022","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9488-465X","authenticated-orcid":false,"given":"Zhiying","family":"Yu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9496-0525","authenticated-orcid":false,"given":"Fenglei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7649-0347","authenticated-orcid":false,"given":"Fang","family":"Dong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7054-8352","authenticated-orcid":false,"given":"Na","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7871-7330","authenticated-orcid":false,"given":"Dabo","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1736-7880","authenticated-orcid":false,"given":"Ling","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,3,20]]},"reference":[{"key":"e_1_2_9_1_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.54.2.117"},{"key":"e_1_2_9_2_2","doi-asserted-by":"publisher","DOI":"10.12998\/wjcc.v8.i15.3249"},{"key":"e_1_2_9_3_2","first-page":"417","article-title":"Comparison of ultrasound biomicroscopy and spectraldomain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy","volume":"9","author":"Ma X. Y.","year":"2016","journal-title":"International Journal of Ophthalmology"},{"key":"e_1_2_9_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2009.103"},{"key":"e_1_2_9_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.01.021"},{"key":"e_1_2_9_6_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1848541"},{"key":"e_1_2_9_7_2","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10028-1230"},{"key":"e_1_2_9_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90149-5"},{"key":"e_1_2_9_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2009.02081.x"},{"key":"e_1_2_9_10_2","first-page":"186","article-title":"Clinical applications of ultrasound biomicroscopy in diagnosis and treatment of lens subluxation","volume":"40","author":"Liu Y. Z.","year":"2004","journal-title":"Chinese Journal of Ophthalmology"},{"key":"e_1_2_9_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00464-0"},{"key":"e_1_2_9_12_2","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/7472195"},{"key":"e_1_2_9_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01169-5"},{"key":"e_1_2_9_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0181-5512(05)81116-7"},{"key":"e_1_2_9_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2014.02.006"},{"key":"e_1_2_9_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.10.006"},{"key":"e_1_2_9_17_2","first-page":"845","article-title":"Exfoliation syndrome and oceludable angles","volume":"92","author":"Ritch R.","year":"1994","journal-title":"Transactions American Ophthalmological Society"},{"key":"e_1_2_9_18_2","volume-title":"Lowe-Lim Primary Closed Angle Glaucoma","author":"Lim A. S. M.","year":"2004"},{"key":"e_1_2_9_19_2","first-page":"678","article-title":"Comparison of swept source anterior segment optical coherence tomography and ultrasound biomicroscopy in measurement of anterior chamber depth and anterior chamber angle data in age-related cataract patients","volume":"54","author":"Shen L.","year":"2018","journal-title":"Chinese Journal of Ophthalmology"},{"key":"e_1_2_9_20_2","doi-asserted-by":"publisher","DOI":"10.3928\/1542-8877-20050301-09"},{"key":"e_1_2_9_21_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.103408"},{"key":"e_1_2_9_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-005-0103-7"},{"key":"e_1_2_9_23_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S99535"},{"key":"e_1_2_9_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s004170050002"},{"key":"e_1_2_9_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.05.024"},{"key":"e_1_2_9_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.11.013"},{"key":"e_1_2_9_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ohc.2005.05.007"},{"key":"e_1_2_9_28_2","first-page":"543","article-title":"Anterior chamber angle examinations using UBM versus OCT","volume":"24","author":"Cui L. J.","year":"2016","journal-title":"Journal of Clinical Ophthalmology"},{"key":"e_1_2_9_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e31818fb41d"}],"container-title":["International Journal of Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijclp\/2022\/7599631.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijclp\/2022\/7599631.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2022\/7599631","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T09:06:46Z","timestamp":1757581606000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2022\/7599631"}},"subtitle":[],"editor":[{"given":"Ahmad","family":"Mansour","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,1]]}},"alternative-id":["10.1155\/2022\/7599631"],"URL":"https:\/\/doi.org\/10.1155\/2022\/7599631","archive":["Portico"],"relation":{},"ISSN":["1368-5031","1742-1241"],"issn-type":[{"value":"1368-5031","type":"print"},{"value":"1742-1241","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1]]},"assertion":[{"value":"2022-01-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-03-08","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-03-20","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"7599631"}}