{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T07:26:37Z","timestamp":1767165997080,"version":"build-2238731810"},"reference-count":24,"publisher":"Wiley","license":[{"start":{"date-parts":[[2022,5,13]],"date-time":"2022-05-13T00:00:00Z","timestamp":1652400000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Key Discipline Project of Shanghai Public Health System","award":["GWV-10.1-XK23"],"award-info":[{"award-number":["GWV-10.1-XK23"]}]},{"name":"Key Discipline Project of Shanghai Public Health System","award":["ynlc201802"],"award-info":[{"award-number":["ynlc201802"]}]},{"name":"Shanghai Sixth People\u2019s Hospital","award":["GWV-10.1-XK23"],"award-info":[{"award-number":["GWV-10.1-XK23"]}]},{"name":"Shanghai Sixth People\u2019s Hospital","award":["ynlc201802"],"award-info":[{"award-number":["ynlc201802"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Applied Bionics and Biomechanics"],"published-print":{"date-parts":[[2022,5,13]]},"abstract":"<jats:p>\n                    Background. Various noninvasive methods of intracranial pressure (ICP) measurement have been proposed. Each has unique advantages and limitations. This study was aimed at investigating the relationships between lateral ventricular asymmetry on admission computed tomography, optic nerve sheath diameter (ONSD), and ICP in traumatic brain injury (TBI) patients. Methods. A prospective observational study was conducted in the patients admitted to our department between October 2018 and October 2020. 20 patients with moderate-severe TBI with a Glasgow Coma Scale of 3\u201312 were enrolled. Lateral ventricle volume (LVV) value measurements were conducted using ITK-SNAP software. The lateral ventricular volume ratio (LVR) was quantified by dividing the larger LVV by the smaller. Results. ONSD and LVR had a good correlation with ICP. Admission LVR of &gt;1.735 was shown to have a sensitivity of 90.9% and a specificity of 88.9% for prediction of ICP increase (\n                    <jats:inline-formula>\n                      <a:math xmlns:a=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M1\">\n                        <a:mtext>AUC<\/a:mtext>\n                        <a:mo>=<\/a:mo>\n                        <a:mn>0.879<\/a:mn>\n                      <\/a:math>\n                    <\/jats:inline-formula>\n                    ; standard\n                    <jats:inline-formula>\n                      <c:math xmlns:c=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M2\">\n                        <c:mtext>error<\/c:mtext>\n                        <c:mo>=<\/c:mo>\n                        <c:mn>0.091<\/c:mn>\n                      <\/c:math>\n                    <\/jats:inline-formula>\n                    ; 95%\n                    <jats:inline-formula>\n                      <e:math xmlns:e=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M3\">\n                        <e:mtext>CI<\/e:mtext>\n                        <e:mo>=<\/e:mo>\n                        <e:mn>0.701<\/e:mn>\n                      <\/e:math>\n                    <\/jats:inline-formula>\n                    to 1.0; significance level\n                    <jats:inline-formula>\n                      <g:math xmlns:g=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M4\">\n                        <g:mi>p<\/g:mi>\n                        <g:mo>&lt;<\/g:mo>\n                        <g:mn>0.004<\/g:mn>\n                      <\/g:math>\n                    <\/jats:inline-formula>\n                    ). Admission ONSD of &gt;5.55\u2009mm was shown to have a sensitivity of 81.8% and a specificity of 88.9% for prediction of ICP increase (\n                    <jats:inline-formula>\n                      <i:math xmlns:i=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M5\">\n                        <i:mtext>AUC<\/i:mtext>\n                        <i:mo>=<\/i:mo>\n                        <i:mn>0.919<\/i:mn>\n                      <\/i:math>\n                    <\/jats:inline-formula>\n                    ; standard\n                    <jats:inline-formula>\n                      <k:math xmlns:k=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M6\">\n                        <k:mtext>error<\/k:mtext>\n                        <k:mo>=<\/k:mo>\n                        <k:mn>0.062<\/k:mn>\n                      <\/k:math>\n                    <\/jats:inline-formula>\n                    ; 95%\n                    <jats:inline-formula>\n                      <m:math xmlns:m=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M7\">\n                        <m:mtext>CI<\/m:mtext>\n                        <m:mo>=<\/m:mo>\n                        <m:mn>0.798<\/m:mn>\n                      <\/m:math>\n                    <\/jats:inline-formula>\n                    to 1.0; significance level\n                    <jats:inline-formula>\n                      <o:math xmlns:o=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M8\">\n                        <o:mi>p<\/o:mi>\n                        <o:mo>&lt;<\/o:mo>\n                        <o:mn>0.002<\/o:mn>\n                      <\/o:math>\n                    <\/jats:inline-formula>\n                    ). Combining the ONSD and LVR, the sensitivity could be improved to 90.9% in parallel test, and the specificity could be improved to 100% in serial test. Conclusion. ONSD and LVR measurements can diagnose elevated ICP in traumatic brain injury patients. ONSD combining with LVR may further improve the diagnostic evaluation.\n                  <\/jats:p>","DOI":"10.1155\/2022\/9808334","type":"journal-article","created":{"date-parts":[[2022,5,13]],"date-time":"2022-05-13T18:50:15Z","timestamp":1652467815000},"page":"1-6","source":"Crossref","is-referenced-by-count":2,"title":["Lateral Ventricular Volume Asymmetry and Optic Nerve Sheath Diameter Predict Intracranial Pressure in Traumatic Brain Injury Patients"],"prefix":"10.1155","volume":"2022","author":[{"given":"Yang","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Critical Care Medicine, Shanghai Jiao Tong University Affiliated Sixth People\u2019s Hospital, Shanghai 200030, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ziming","family":"Yuan","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Shanghai Jiao Tong University Affiliated Sixth People\u2019s Hospital, Shanghai 200030, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zuoyan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Shanghai Jiao Tong University Affiliated Sixth People\u2019s Hospital, Shanghai 200030, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiawei","family":"Shang","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Shanghai Jiao Tong University Affiliated Sixth People\u2019s Hospital, Shanghai 200030, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingna","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Shanghai Jiao Tong University Affiliated Sixth People\u2019s Hospital, Shanghai 200030, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6154-5560","authenticated-orcid":true,"given":"Wei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Shanghai Jiao Tong University Affiliated Sixth People\u2019s Hospital, Shanghai 200030, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(18)32203-7"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-012-2655-4"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1111\/ane.12527"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1002356"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-016-1239-z"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1097\/ana.0000000000000295"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1097\/mej.0000000000000070"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1186\/cc13012"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-018-5305-7"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1186\/2046-4053-2-62"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.34.7.1285"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1089\/neu.2014.3696"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1227\/neu.0000000000001432"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-008-1149-x"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2018-312934"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1007\/s10072-019-04076-y"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.3171\/2014.10.Jns141728"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.3340\/jkns.2013.54.3.211"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1089\/neu.2011.1776"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0707534"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1214609"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1080\/02688690050004525"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.2176\/nmc.33.552"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2017.11.149"}],"updated-by":[{"DOI":"10.1155\/2023\/9767615","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"record-id":"61128"},{"DOI":"10.1155\/2023\/9767615","type":"retraction","label":"Retraction","source":"publisher","updated":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000}}],"container-title":["Applied Bionics and Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/abb\/2022\/9808334.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/abb\/2022\/9808334.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/abb\/2022\/9808334.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,13]],"date-time":"2022-05-13T18:50:20Z","timestamp":1652467820000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/abb\/2022\/9808334\/"}},"subtitle":[],"editor":[{"given":"Fahd Abd","family":"Algalil","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2022,5,13]]},"references-count":24,"alternative-id":["9808334","9808334"],"URL":"https:\/\/doi.org\/10.1155\/2022\/9808334","relation":{},"ISSN":["1754-2103","1176-2322"],"issn-type":[{"value":"1754-2103","type":"electronic"},{"value":"1176-2322","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5,13]]}}}