{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:16:33Z","timestamp":1740147393702,"version":"3.37.3"},"reference-count":34,"publisher":"Wiley","license":[{"start":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T00:00:00Z","timestamp":1672963200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013096","name":"Science and Technology Project of State Grid","doi-asserted-by":"publisher","award":["4000-202055048A-0-0-00"],"award-info":[{"award-number":["4000-202055048A-0-0-00"]}],"id":[{"id":"10.13039\/501100013096","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Control Science and Engineering"],"published-print":{"date-parts":[[2023,1,6]]},"abstract":"<jats:p>As a nonlinear control method, the Euler\u2013Lagrange- (EL-) based passivity-based control (PBC) has been studied for grid-tied converters based on energy function to achieve better performance. However, the EL-based PBC method is dependent on an accurate mathematical model. In the traditional EL-based PBC research for LCL-filtered grid-tied inverter, the effect of the digital control delay is rarely considered and the stability under the grid impedance uncertainties is not discussed, especially in the capacitive grid or complex weak grid. To address these concerns, this study proposes a modified EL-based PBC method based on the output admittance reshaping for LCL-filtered grid-tied inverters. The system\u2019 passive region is expanded by adding capacitor current feedback loop up to the Nyquist frequency. The potential resonance is thus eliminated irrespective of the grid impedance. Additionally, the stable region and control parameters design methods of the modified EL-based PBC method with inverter-side control are also carried out. To verify the correctness of the theoretical analysis, both simulation and experimental results are investigated from a 3\u2009kW grid-tied inverter prototype.<\/jats:p>","DOI":"10.1155\/2023\/3373863","type":"journal-article","created":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T16:24:20Z","timestamp":1673022260000},"page":"1-11","source":"Crossref","is-referenced-by-count":0,"title":["Modified Passivity-Based Control for LCL-Filtered Grid-Tied Inverter with Output Admittance Reshaping"],"prefix":"10.1155","volume":"2023","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3931-4878","authenticated-orcid":true,"given":"Han","family":"Wang","sequence":"first","affiliation":[{"name":"The Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gang","family":"Shi","sequence":"additional","affiliation":[{"name":"The Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8292-6760","authenticated-orcid":true,"given":"Jianwen","family":"Zhang","sequence":"additional","affiliation":[{"name":"The Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miao","family":"Zhu","sequence":"additional","affiliation":[{"name":"The Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xu","family":"Cai","sequence":"additional","affiliation":[{"name":"The Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai 200240, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2004.833453"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1109\/tcsii.2020.2990447"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2013.2279206"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2012.2222931"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2013.2279191"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2017.2705288"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1109\/tia.2010.2049974"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2019.2906217"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2015.2433253"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2013.2290771"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2020.3008160"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2015.2478738"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1109\/tii.2014.2324492"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1109\/tia.2013.2266892"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2015.2401612"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2015.2510984"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2017.2677341"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2019.2963200"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2017.08.001"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1109\/tii.2017.2747593"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1109\/tia.2019.2959594"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1109\/jestpe.2018.2826365"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2012.2218133"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.3390\/en12081421"},{"issue":"3","key":"25","first-page":"15","article-title":"Passivity-based control of euler-Lagrange systems: mechanical, electrical and electromechanical applications","volume":"6","author":"R. Ortega","year":"1998","journal-title":"Ind Robot An Internation Journal"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1109\/tpwrs.2018.2789450"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2017.2651948"},{"key":"28","article-title":"Passivity-based decoupling control strategy of single-phase LCL-type VSRs for harmonics suppression in railway power systems. International Journal of Electrical","volume":"117","author":"L. Yuxing","year":"2020","journal-title":"Power and Energy Systems"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2019.06.015"},{"key":"30","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2013.2262473"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2019.2955861"},{"key":"32","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2020.2967239"},{"key":"33","doi-asserted-by":"publisher","DOI":"10.1049\/iet-pel:20070286"},{"key":"34","doi-asserted-by":"publisher","DOI":"10.1109\/access.2019.2935806"}],"container-title":["Journal of Control Science and Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/jcse\/2023\/3373863.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jcse\/2023\/3373863.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/jcse\/2023\/3373863.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T16:24:27Z","timestamp":1673022267000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/jcse\/2023\/3373863\/"}},"subtitle":[],"editor":[{"given":"Carlos-Andr\u00e9s","family":"Garc\u00eda","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2023,1,6]]},"references-count":34,"alternative-id":["3373863","3373863"],"URL":"https:\/\/doi.org\/10.1155\/2023\/3373863","relation":{},"ISSN":["1687-5257","1687-5249"],"issn-type":[{"type":"electronic","value":"1687-5257"},{"type":"print","value":"1687-5249"}],"subject":[],"published":{"date-parts":[[2023,1,6]]}}}