{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T02:06:29Z","timestamp":1789092389570,"version":"build-2803163510"},"reference-count":37,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T00:00:00Z","timestamp":1724889600000},"content-version":"vor","delay-in-days":241,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52275006"],"award-info":[{"award-number":["52275006"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Applied Bionics and Biomechanics"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:p>Upper limb exoskeleton rehabilitation devices can improve the quality of rehabilitation and relieve the pressure of rehabilitation medical treatment, which is a research hotspot in the field of medical robots. Aiming at the problems such as large volume, high cost, low comfort, and difficulty in promotion of traditional exoskeleton rehabilitation devices, and considering the lightweight, discontinuous, high flexibility, and high biomimetic characteristics of tensegrity structure, we designed an upper limb bionic exoskeleton rehabilitation device based on tensegrity structure. First, this article uses mapping methods to establish a mapping model for upper limb exoskeletons based on the tensegrity structure and designs the overall structure of upper limb exoskeletons based on the mapping model. Second, a bionic elbow joint device based on gear and rack was designed, and the stability of the bionic elbow joint was proved using the positive definite matrix method. This device can simulate the micro displacement between bones of the human elbow joint, improve the axial matching ability between the upper limbs and the rehabilitation device, and enhance the comfort of rehabilitation. Third, an impedance control scheme based on back propagation (BP) neural network was designed to address the low control accuracy of flexible structures and patient spasms. Finally, we designed the impedance control scheme of the PSO\u2013BP neural network based on a fuzzy rehabilitation state evaluator. The experimental results show that the exoskeleton rehabilitation device has good flexion motion stability and assist ability and has significant advantages in volume and mobility. The control strategy proposed in this paper has high control precision and adaptive ability and has potential application value in the field of medical rehabilitation.<\/jats:p>","DOI":"10.1155\/2024\/5905225","type":"journal-article","created":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T15:21:50Z","timestamp":1724944910000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Design and Control of an Upper Limb Bionic Exoskeleton Rehabilitation Device Based on Tensegrity Structure"],"prefix":"10.1155","volume":"2024","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-0882-2375","authenticated-orcid":false,"given":"Peng","family":"Ni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7246-8145","authenticated-orcid":false,"given":"Jianwei","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jialin","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,8,29]]},"reference":[{"key":"e_1_2_9_1_2","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/5370127"},{"key":"e_1_2_9_2_2","doi-asserted-by":"publisher","DOI":"10.3390\/s23084042"},{"key":"e_1_2_9_3_2","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/741359"},{"key":"e_1_2_9_4_2","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-11-3"},{"key":"e_1_2_9_5_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSMC.2015.2497205"},{"key":"e_1_2_9_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s41133-020-00043-x"},{"key":"e_1_2_9_7_2","doi-asserted-by":"crossref","unstructured":"ParkY.-L. ChenB.-R. YoungD. StirlingL. WoodR. J. GoldfieldE. andNagpalR. Bio-inspired active soft orthotic device for ankle foot pathologies IEEE\/RSJ International Conference on Intelligent Robots and Systems 2011 San Francisco CA USA IEEE 4488\u20134495 https:\/\/doi.org\/10.1109\/IROS.2011.6094933.","DOI":"10.1109\/IROS.2011.6094933"},{"key":"e_1_2_9_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/0278364917706743"},{"key":"e_1_2_9_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-17836-9"},{"key":"e_1_2_9_10_2","doi-asserted-by":"crossref","unstructured":"KimberJ. JiZ. PetridouA. SippleT. BarhydtK. BoggsJ. DosiekL. andRieffelJ. Low-cost wireless modular soft tensegrity robots 2019 2nd IEEE International Conference on Soft Robotics (RoboSoft) 2019 Seoul Korea (South) IEEE 88\u201393 https:\/\/doi.org\/10.1109\/ROBOSOFT.2019.8722723 2-s2.0-85067119085.","DOI":"10.1109\/ROBOSOFT.2019.8722723"},{"key":"e_1_2_9_11_2","doi-asserted-by":"crossref","unstructured":"FriesenJ. PogueA. BewleyT. de OliveiraM. SkeltonR. andSunspiralV. DuCTT: a tensegrity robot for exploring duct systems 2014 IEEE International Conference on Robotics and Automation (ICRA) 2014 Hong Kong China IEEE 4222\u20134228 https:\/\/doi.org\/10.1109\/ICRA.2014.6907473 2-s2.0-84923115058.","DOI":"10.1109\/ICRA.2014.6907473"},{"key":"e_1_2_9_12_2","doi-asserted-by":"crossref","unstructured":"SabelhausA. P. JiH. HyltonP. MadaanY. YangC. AgoginoA. M. FriesenJ. andSunSpiralV. Mechanism design and simulation of the ULTRA spine: a tensegrity robot 5 39th Mechanisms and Robotics Conference 2015 Boston Massachusetts USA ASME 1\u201312 https:\/\/doi.org\/10.1115\/DETC2015-47583 2-s2.0-84973345148.","DOI":"10.1115\/DETC2015-47583"},{"key":"e_1_2_9_13_2","doi-asserted-by":"crossref","unstructured":"BohmV. KaufholdT. SchaleF. andZimmermannK. Spherical mobile robot based on a tensegrity structure with curved compressed members 2016 IEEE International Conference on Advanced Intelligent Mechatronics (AIM) 2016 Banff AB Canada IEEE 1509\u20131514 https:\/\/doi.org\/10.1109\/AIM.2016.7576984 2-s2.0-84992315808.","DOI":"10.1109\/AIM.2016.7576984"},{"key":"e_1_2_9_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00419-016-1183-z"},{"key":"e_1_2_9_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12206-017-0640-0"},{"key":"e_1_2_9_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2021.3081594"},{"key":"e_1_2_9_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11042-016-3776-5"},{"key":"e_1_2_9_18_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2007.901934"},{"key":"e_1_2_9_19_2","doi-asserted-by":"publisher","DOI":"10.3390\/s23187841"},{"key":"e_1_2_9_20_2","first-page":"4","article-title":"A study on human upper-limb muscles activities during daily upper-limb motions","volume":"12","author":"Gopura R.","year":"2010","journal-title":"International Journal of Bioelectromagnetism"},{"key":"e_1_2_9_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.aott.2018.02.005"},{"key":"e_1_2_9_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsolstr.2010.01.012"},{"key":"e_1_2_9_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsolstr.2007.02.041"},{"key":"e_1_2_9_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-7683(03)00400-1"},{"key":"e_1_2_9_25_2","doi-asserted-by":"publisher","DOI":"10.3390\/s20092482"},{"key":"e_1_2_9_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00132585-200311010-00001"},{"key":"e_1_2_9_27_2","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/258374"},{"key":"e_1_2_9_28_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2006.875558"},{"key":"e_1_2_9_29_2","doi-asserted-by":"publisher","DOI":"10.3390\/app10196976"},{"key":"e_1_2_9_30_2","doi-asserted-by":"publisher","DOI":"10.3390\/s23125722"},{"key":"e_1_2_9_31_2","doi-asserted-by":"publisher","DOI":"10.1063\/5.0118066"},{"key":"e_1_2_9_32_2","doi-asserted-by":"publisher","DOI":"10.15837\/ijccc.2020.4.3814"},{"key":"e_1_2_9_33_2","doi-asserted-by":"publisher","DOI":"10.1053\/apmr.2003.50066"},{"key":"e_1_2_9_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2017.2787686"},{"key":"e_1_2_9_35_2","doi-asserted-by":"crossref","unstructured":"SongP. YuY. andZhangX. Impedance control of robots: an overview 2017 2nd International Conference on Cybernetics Robotics and Control (CRC) 2017 Kitakyushu Japan IEEE 51\u201355 https:\/\/doi.org\/10.1109\/CRC.2017.20 2-s2.0-85047439680.","DOI":"10.1109\/CRC.2017.20"},{"key":"e_1_2_9_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chemolab.2015.08.020"},{"key":"e_1_2_9_37_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2018.2835410"}],"container-title":["Applied Bionics and Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/2024\/5905225","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,29]],"date-time":"2024-08-29T15:21:57Z","timestamp":1724944917000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/2024\/5905225"}},"subtitle":[],"editor":[{"given":"I-Lin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["10.1155\/2024\/5905225"],"URL":"https:\/\/doi.org\/10.1155\/2024\/5905225","archive":["Portico"],"relation":{},"ISSN":["1176-2322","1754-2103"],"issn-type":[{"value":"1176-2322","type":"print"},{"value":"1754-2103","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"2024-02-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-25","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-29","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"5905225"}}