{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,24]],"date-time":"2025-08-24T01:57:51Z","timestamp":1756000671562,"version":"3.41.2"},"reference-count":27,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,12,4]],"date-time":"2006-12-04T00:00:00Z","timestamp":1165190400000},"content-version":"vor","delay-in-days":337,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","award":["EB001685"],"award-info":[{"award-number":["EB001685"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Biomedical Imaging"],"published-print":{"date-parts":[[2006,1]]},"abstract":"<jats:p>We describe the system design of the first bioluminescence tomography (BLT) system for parallel acquisition of multiple bioluminescent views around a mouse in a number of spectral channels simultaneously. The primary component of this BLT system is a novel mirror module and a unique mouse holder. The mirror module consists of a mounting plate and four mirrors with stages. These mirror stages are right triangular blocks symmetrically arranged and attached to the mounting plate such that the hypotenuse surfaces of the triangular blocks all make 45<jats:sup>\u2218<\/jats:sup> to the plate surface. The cylindrical\/polygonal mouse holder has semitransparent rainbow bands on its side surface for the acquisition of spectrally resolved data. Numerical studies and experiments are performed to demonstrate the feasibility of this system. It is shown that bioluminescent signals collected using our system can produce a similar BLT reconstruction quality while reducing the data acquisition time, as compared to the sequential data acquisition mode.<\/jats:p>","DOI":"10.1155\/ijbi\/2006\/58601","type":"journal-article","created":{"date-parts":[[2006,12,27]],"date-time":"2006-12-27T08:07:13Z","timestamp":1167206833000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["The First Bioluminescence Tomography System for Simultaneous Acquisition of Multiview and Multispectral Data"],"prefix":"10.1155","volume":"2006","author":[{"given":"Ge","family":"Wang","sequence":"first","affiliation":[]},{"given":"Haiou","family":"Shen","sequence":"additional","affiliation":[]},{"given":"Kumar","family":"Durairaj","sequence":"additional","affiliation":[]},{"given":"Xin","family":"Qian","sequence":"additional","affiliation":[]},{"given":"Wenxiang","family":"Cong","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2006,12,4]]},"reference":[{"key":"e_1_2_1_1_2","doi-asserted-by":"crossref","unstructured":"RiceB. W. CableM. D. andNelsonM. B. In vivo imaging of light-emitting probes 2001 6 no. 4 432\u2013440 https:\/\/doi.org\/10.1117\/1.1413210.","DOI":"10.1117\/1.1413210"},{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","unstructured":"ContagC. H.andBachmannM. H. Advances in in vivo bioluminescence imaging of gene expression 2002 4 235\u2013260 https:\/\/doi.org\/10.1146\/annurev.bioeng.4.111901.093336.","DOI":"10.1146\/annurev.bioeng.4.111901.093336"},{"key":"e_1_2_1_3_2","doi-asserted-by":"crossref","unstructured":"NtziachristosV. RipollJ. WangL. V. andWeisslederR. Looking and listening to light: the evolution of whole-body photonic imaging 2005 23 no. 3 313\u2013320 https:\/\/doi.org\/10.1038\/nbt1074.","DOI":"10.1038\/nbt1074"},{"key":"e_1_2_1_4_2","unstructured":"WangG. HoffmanE. A. andMcLennanG. Systems and methods for bioluminescent CT reconstruction Patent disclosure filled July 2002; US provisional patent application filled March 2003; US patent application filed March 2004."},{"key":"e_1_2_1_5_2","unstructured":"WangG.et al. Multi-spectral bioluminescence tomography methods and systems Patent disclosure filed with University of Iowa Research Foundation April 2004; provisional patent filed."},{"key":"e_1_2_1_6_2","unstructured":"WangG. KumarD. ShenH. QianX. andCongW. The Optical molecular tomography systems and methods for simultaneous acquisition of multi-view and multi-spectral data Patent disclosure filed with University of Iowa Research Foundation May 2006."},{"key":"e_1_2_1_7_2","unstructured":"WangG. HoffmanE. A. McLennanG.et al. Development of the first bioluminescent CT scanner 2003 229(P)."},{"key":"e_1_2_1_8_2","doi-asserted-by":"crossref","unstructured":"WangG. LiY. andJiangM. Uniqueness theorems in bioluminescence tomography 2004 31 no. 8 2289\u20132299 https:\/\/doi.org\/10.1118\/1.1766420.","DOI":"10.1118\/1.1766420"},{"key":"e_1_2_1_9_2","doi-asserted-by":"crossref","unstructured":"JiangM.andWangG. Image reconstruction for bioluminescence tomography 5535 335\u2013351 Proceedings of SPIE https:\/\/doi.org\/10.1117\/12.559038.","DOI":"10.1117\/12.559038"},{"key":"e_1_2_1_10_2","doi-asserted-by":"crossref","unstructured":"CongW. KumarD. LiuY. CongA. andWangG. A practical method to determine the light source distribution in bioluminescent imaging 5535 679\u2013686 Proceedings of SPIE https:\/\/doi.org\/10.1117\/12.560524.","DOI":"10.1117\/12.560524"},{"key":"e_1_2_1_11_2","doi-asserted-by":"crossref","unstructured":"CongW. WangG. KumarD.et al. Practical reconstruction method for bioluminescence tomography 2005 13 no. 18 6756\u20136771 https:\/\/doi.org\/10.1364\/OPEX.13.006756.","DOI":"10.1364\/OPEX.13.006756"},{"key":"e_1_2_1_12_2","doi-asserted-by":"crossref","unstructured":"CongW.andWangG. Boundary integral method for bioluminescence tomography 2006 11 no. 2 3 https:\/\/doi.org\/10.1117\/1.2191790.","DOI":"10.1117\/1.2191790"},{"key":"e_1_2_1_13_2","doi-asserted-by":"crossref","unstructured":"CongW. KumarD. WangL. V. andWangG. A Born-type approximation method for bioluminescence tomography 2006 33 no. 3 679\u2013686 https:\/\/doi.org\/10.1118\/1.2168293.","DOI":"10.1118\/1.2168293"},{"key":"e_1_2_1_14_2","doi-asserted-by":"crossref","unstructured":"CongA.andWangG. Multispectral bioluminescence tomography: methodology and simulation 2006 2006 7 https:\/\/doi.org\/10.1155\/IJBI\/2006\/57614.","DOI":"10.1155\/IJBI\/2006\/57614"},{"key":"e_1_2_1_15_2","doi-asserted-by":"crossref","unstructured":"GuX. ZhangQ. LarcomL. andJiangH. Three-dimensional bioluminescence tomography with model-based reconstruction 2004 12 no. 17 3996\u20134000 https:\/\/doi.org\/10.1364\/OPEX.12.003996.","DOI":"10.1364\/OPEX.12.003996"},{"key":"e_1_2_1_16_2","unstructured":"KuoC. CoquozO. TroyT. ZwargD. andRiceB. Bioluminescent tomography for in vivo localization and quantification of luminescent sources from a multiple-view imaging system 2005 4."},{"key":"e_1_2_1_17_2","doi-asserted-by":"crossref","unstructured":"AlexandrakisG. RannouF. R. andChatziioannouA. F. Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study 2005 50 no. 17 4225\u20134241 https:\/\/doi.org\/10.1088\/0031-9155\/50\/17\/021.","DOI":"10.1088\/0031-9155\/50\/17\/021"},{"key":"e_1_2_1_18_2","doi-asserted-by":"crossref","unstructured":"ChaudhariA. J. DarvasF. BadingJ. R.et al. Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging 2005 50 no. 23 5421\u20135441 https:\/\/doi.org\/10.1088\/0031-9155\/50\/23\/001.","DOI":"10.1088\/0031-9155\/50\/23\/001"},{"key":"e_1_2_1_19_2","doi-asserted-by":"crossref","unstructured":"SlavineN. V. LewisM. A. RicherE. andAntichP. P. Iterative reconstruction method for light emitting sources based on the diffusion equation 2006 33 no. 1 61\u201368 https:\/\/doi.org\/10.1118\/1.2138007.","DOI":"10.1118\/1.2138007"},{"key":"e_1_2_1_20_2","doi-asserted-by":"crossref","unstructured":"DehghaniH. DavisS. C. JiangS. PogueB. W. PaulsenK. D. andPattersonM. S. Spectrally resolved bioluminescence optical tomography 2006 31 no. 3 365\u2013367 https:\/\/doi.org\/10.1364\/OL.31.000365.","DOI":"10.1364\/OL.31.000365"},{"key":"e_1_2_1_21_2","doi-asserted-by":"crossref","unstructured":"WangG. ShenH. CongW. ZhaoS. andWeiG. W. Temperature-modulated bioluminescence tomography 2006 14 no. 17 7852\u20137871 https:\/\/doi.org\/10.1364\/OE.14.007852.","DOI":"10.1364\/OE.14.007852"},{"key":"e_1_2_1_22_2","doi-asserted-by":"crossref","unstructured":"ZhaoH. DoyleT. C. CoquozO. KalishF. RiceB. W. andContagC. H. Emission spectra of bioluminescent reporters and interaction with mammalian tissue determine the sensitivity of detection in vivo 2005 10 no. 4 9 https:\/\/doi.org\/10.1117\/1.2032388.","DOI":"10.1117\/1.2032388"},{"volume-title":"Wave Propagation and Scattering in Random Media","year":"1997","author":"Ishimaru A.","key":"e_1_2_1_23_2"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1137\/1.9780898718324"},{"key":"e_1_2_1_25_2","unstructured":"http:\/\/omlc.ogi.edu\/spectra\/hemoglobin\/index.html."},{"volume-title":"Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis","year":"2000","author":"Tuchin V.","key":"e_1_2_1_26_2"},{"key":"e_1_2_1_27_2","doi-asserted-by":"crossref","unstructured":"CheongW. F. PrahlS. A. andWelchA. J. A review of the optical properties of biological tissues 1990 26 no. 12 2166\u20132185 https:\/\/doi.org\/10.1109\/3.64354.","DOI":"10.1109\/3.64354"}],"container-title":["International Journal of Biomedical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/ijbi\/2006\/058601.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/IJBI\/2006\/58601","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,6]],"date-time":"2024-06-06T20:30:49Z","timestamp":1717705849000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/IJBI\/2006\/58601"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["10.1155\/IJBI\/2006\/58601"],"URL":"https:\/\/doi.org\/10.1155\/ijbi\/2006\/58601","archive":["Portico"],"relation":{},"ISSN":["1687-4188","1687-4196"],"issn-type":[{"type":"print","value":"1687-4188"},{"type":"electronic","value":"1687-4196"}],"subject":[],"published":{"date-parts":[[2006,1]]},"assertion":[{"value":"2006-12-04","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"058601"}}