{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T00:31:53Z","timestamp":1773793913204,"version":"3.50.1"},"reference-count":29,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"vor","delay-in-days":316,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Electrical and Computer Engineering"],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:p>Rural dwellers need a well\u2010equipped healthcare service for a decent life. Most of the rural areas located in southern parts of India away from the grid connection thereby lack in electricity. Unreliable electric power leads to the limited access or inaccessibility of most essential medical equipment in the clinic. The deficiency has also reduced rural healthcare centers ethics criteria. This research work finds all the available resources in the rural healthcare clinic and proposes hybrid solar PV source and supercapacitor\u2010based approaches to make sure of reliable energy access and uninterrupted power supply. Any healthcare facilities include an emergency room, waiting hall, nursing room, consulting room, delivery room, male and female room, and a testing lab. It may take a daily average energy consumption of 16\u2009kWh with 3\u2009kW peak demand. In the input side, solar PV system with an H\u2010type clamped capacitor\u2013based boost converter is proposed for the reduction of input current ripples and power switch conduction losses. At the load side, a capacitor with a switch (switched capacitor) is considered to reduce voltage stress of the components present in the topology and to attain high gain. This research work adopts interleaved structure\u2010based capacitors for current ripple reduction, and the series structure is considered to attain high gain. The proposed novel converter takes the input voltage of 40\u2009V and produces the output voltage of 280\u2009V. The DC link output is then connected with the voltage source inverter (VSI) to get a desired output. The proposed novel converter is employed to run a 3\u03a6 induction motor for the AC load with the rating of 400\u2009V, 15\u2009A AC power. MATLAB R2015a software is preferred for the simulation analysis.<\/jats:p>","DOI":"10.1155\/jece\/8855158","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T15:45:51Z","timestamp":1763048751000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Hybrid Renewable Source Powered Dual Input Single Output Converter With High Voltage Gain for Rural Healthcare Facilities"],"prefix":"10.1155","volume":"2025","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6245-6730","authenticated-orcid":false,"given":"K. M. D. Riyaz","family":"Ali","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6044-1794","authenticated-orcid":false,"given":"W. Abitha","family":"Memala","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8422-8656","authenticated-orcid":false,"given":"W. Margaret","family":"Amutha","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"e_1_2_9_1_2","doi-asserted-by":"publisher","DOI":"10.3390\/en15249554"},{"key":"e_1_2_9_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.egyr.2016.06.001"},{"key":"e_1_2_9_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2016.04.042"},{"key":"e_1_2_9_4_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2017.2652318"},{"key":"e_1_2_9_5_2","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2015.2393846"},{"key":"e_1_2_9_6_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2015.2429651"},{"key":"e_1_2_9_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2018.2878127"},{"key":"e_1_2_9_8_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2017.2719040"},{"key":"e_1_2_9_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/tie.2014.2364797"},{"key":"e_1_2_9_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/tec.2018.2876725"},{"key":"e_1_2_9_11_2","doi-asserted-by":"publisher","DOI":"10.3390\/app11020860"},{"key":"e_1_2_9_12_2","doi-asserted-by":"publisher","DOI":"10.11591\/ijpeds.v10.i1.pp288-299"},{"key":"e_1_2_9_13_2","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/995\/1\/012062"},{"key":"e_1_2_9_14_2","doi-asserted-by":"publisher","DOI":"10.3390\/machines10010047"},{"key":"e_1_2_9_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/cta.2360"},{"key":"e_1_2_9_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2020.3048043"},{"key":"e_1_2_9_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2020.2987083"},{"key":"e_1_2_9_18_2","doi-asserted-by":"publisher","DOI":"10.1109\/jestpe.2018.2873154"},{"key":"e_1_2_9_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/access.2020.3041738"},{"key":"e_1_2_9_20_2","doi-asserted-by":"publisher","DOI":"10.1109\/access.2020.2983757"},{"key":"e_1_2_9_21_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2020.3015390"},{"key":"e_1_2_9_22_2","doi-asserted-by":"crossref","unstructured":"MayerR. El KattelM. B. Douglas PossamaiM. BruningC. andVidal Garcia OliveiraS. Analysis of a Multi-Phase Interleaved Bidirectional DC\/DC Power Converter With Coupled Inductor 2017 Brazilian Power Electronics Conference (COBEP) 2017 IEEE 1\u20136.","DOI":"10.1109\/COBEP.2017.8257228"},{"key":"e_1_2_9_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2015.2496274"},{"key":"e_1_2_9_24_2","first-page":"1711","article-title":"Non-Isolated Bidirectional Soft-Switching Current-Fed Lcl Resonant dc\/dc Converter to Interface Energy Storage in Dc Microgrid","volume":"52","author":"Rathore A. K.","year":"2016","journal-title":"IEEE Transactions on Industry Applications"},{"key":"e_1_2_9_25_2","doi-asserted-by":"publisher","DOI":"10.1109\/tpel.2013.2271328"},{"key":"e_1_2_9_26_2","doi-asserted-by":"publisher","DOI":"10.11591\/ijpeds.v8.i4.pp1894-1902"},{"key":"e_1_2_9_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prime.2024.100492"},{"key":"e_1_2_9_28_2","doi-asserted-by":"crossref","unstructured":"YoshiokaN. HusenJ. H. TunH. T. ChenZ. WashizakiH. andFukazawaY. Landscape of Requirements Engineering for Machine Learning-Based AI Systems 2021 28th Asia-Pacific Software Engineering Conference Workshops (APSEC Workshops) December 2021 IEEE 5\u20138.","DOI":"10.1109\/APSECW53869.2021.00011"},{"key":"e_1_2_9_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10489-022-03288-8"}],"container-title":["Journal of Electrical and Computer Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/jece\/8855158","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1155\/jece\/8855158","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/jece\/8855158","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T20:38:36Z","timestamp":1773779916000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/jece\/8855158"}},"subtitle":[],"editor":[{"given":"Palanisamy","family":"R.","sequence":"additional","affiliation":[]}],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["10.1155\/jece\/8855158"],"URL":"https:\/\/doi.org\/10.1155\/jece\/8855158","archive":["Portico"],"relation":{},"ISSN":["2090-0147","2090-0155"],"issn-type":[{"value":"2090-0147","type":"print"},{"value":"2090-0155","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2025-07-21","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-29","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-13","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"8855158"}}