{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T08:58:47Z","timestamp":1790413127526,"version":"4.1.0"},"reference-count":37,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T00:00:00Z","timestamp":1787529600000},"content-version":"vor","delay-in-days":235,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Dentistry"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:p>This in vitro study evaluated the torque accuracy of spring\u2010style mechanical torque\u2010limiting devices (MTLDs) from three manufacturers under clinically simulated conditions. Nine devices (Implance, Astra Tech, and DIO) were tested with a digital torque tester. Target torque values were 25 and 35 Ncm for Implance and Astra Tech and 20 and 35 Ncm for DIO. Each device underwent 40 experimental cycles, including baseline measurement, mechanical fatigue by 20 loading repetitions at target torque, post\u2010fatigue measurement, and steam sterilization. Torque difference and percentage deviation from target value were calculated; deviations exceeding \u00b110% were classified as outside the acceptable range. Torque difference and percentage deviation were analyzed using aligned rank transform (ART) mixed ANOVA with Holm\u2010adjusted comparisons. The experimental cycle significantly affected torque difference in all manufacturers, whereas the measurement stage did not. Percentage deviation was significantly associated with experimental cycle, manufacturer, and their interaction. Overall median percentage deviation was 11.43% for Implance, 3.33% for Astra Tech, and 16.67% for DIO. Torque accuracy was manufacturer\u2010dependent and changed over repeated experimental cycles comprising mechanical loading and sterilization, supporting verification before clinical use and periodic recalibration of spring\u2010style MTLDs.<\/jats:p>","DOI":"10.1155\/ijod\/4941557","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T11:54:34Z","timestamp":1787572474000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Torque Accuracy of Spring\u2010Style Dental Torque Wrenches After Repeated Mechanical Loading and Sterilization: An In Vitro Study"],"prefix":"10.1155","volume":"2026","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9395-0579","authenticated-orcid":false,"given":"Batuhan","family":"Ayd\u0131n","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2803-9463","authenticated-orcid":false,"given":"Zehra","family":"G\u00fclerol Ayd\u0131n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5814-5451","authenticated-orcid":false,"given":"Serkan","family":"Polat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,8,24]]},"reference":[{"key":"e_1_2_14_1_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0757.2008.00267.x"},{"key":"e_1_2_14_2_2","first-page":"491","article-title":"Assessment of Implant Stability as a Prognostic Determinant","volume":"11","author":"Meredith N.","year":"1998","journal-title":"The International journal of prosthodontics"},{"key":"e_1_2_14_3_2","doi-asserted-by":"publisher","DOI":"10.1556\/imas.5.2013.4.3"},{"key":"e_1_2_14_4_2","first-page":"769","article-title":"Correlation Between Placement Torque and Survival of Single-Tooth Implants","volume":"20","author":"Ottoni J. M. P.","year":"2005","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2010.05.013"},{"key":"e_1_2_14_6_2","first-page":"220","article-title":"Accuracy of Mechanical Torque-Limiting Devices for Implants","volume":"17","author":"Standlee J. P.","year":"2002","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_7_2","first-page":"367","article-title":"Implant-Abutment Screw Joint Preload of 7 Hex-Top Abutment Systems","volume":"16","author":"Tan K. B.","year":"2001","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(08)60154-7"},{"key":"e_1_2_14_9_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-021-01703-z"},{"key":"e_1_2_14_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-849X.2009.00524.x"},{"key":"e_1_2_14_11_2","first-page":"74","article-title":"The Effect of Sterilization and Number of use on the Accuracy of Friction-Style Mechanical Torque Limiting Devices for Dental Implants","volume":"11","author":"Fayaz A.","year":"2014","journal-title":"Dental Research Journal"},{"key":"e_1_2_14_12_2","first-page":"743","article-title":"Accuracy of a Manual Torque Application Device for Morse-Taper Implants: A Technical Note","volume":"19","author":"Cehreli M. C.","year":"2004","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_14_13_2","doi-asserted-by":"publisher","DOI":"10.2147\/CCIDEN.S32052"},{"key":"e_1_2_14_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/jcpe.13733"},{"key":"e_1_2_14_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00008505-199600510-00003"},{"key":"e_1_2_14_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(05)80377-4"},{"key":"e_1_2_14_17_2","first-page":"394","article-title":"Accuracy of Electronic Implant Torque Controllers Following Time in Clinical Service","volume":"16","author":"Mitrani R.","year":"2001","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_18_2","first-page":"19","article-title":"The Biomechanics of Force Distribution in Implant-Supported Prostheses","volume":"8","author":"Weinberg L. A.","year":"1993","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_19_2","first-page":"179","article-title":"Clinical Evaluation of Single-Tooth Restorations Supported by Osseointegrated Implants: A Retrospective Study","volume":"9","author":"Ekfeldt A.","year":"1994","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_20_2","first-page":"450","article-title":"Osseointegrated Implants for Single-Tooth Replacement: A Prospective 5-Year Multicenter Study","volume":"11","author":"Henry P. J.","year":"1996","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_14_21_2","doi-asserted-by":"publisher","DOI":"10.4103\/jfmpc.jfmpc_1343_20"},{"key":"e_1_2_14_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2012.08.008"},{"key":"e_1_2_14_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2004.03.010"},{"key":"e_1_2_14_24_2","first-page":"112","article-title":"Evaluation of the Accuracy and Related Factors of the Mechanical Torque-Limiting Device for Dental Implants","volume":"10","author":"Kazemi M.","year":"2013","journal-title":"Journal of Dentistry (Tehran, Iran)"},{"key":"e_1_2_14_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2014.11.017"},{"key":"e_1_2_14_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2022.08.013"},{"key":"e_1_2_14_27_2","doi-asserted-by":"publisher","DOI":"10.11607\/jomi.2014suppl.g4.4"},{"key":"e_1_2_14_28_2","doi-asserted-by":"publisher","DOI":"10.1563\/aaid-joi-D-16-00129"},{"key":"e_1_2_14_29_2","doi-asserted-by":"publisher","DOI":"10.3390\/ma15041392"},{"key":"e_1_2_14_30_2","doi-asserted-by":"publisher","DOI":"10.3758\/BF03193146"},{"key":"e_1_2_14_31_2","doi-asserted-by":"publisher","DOI":"10.4324\/9780203771587"},{"key":"e_1_2_14_32_2","doi-asserted-by":"publisher","DOI":"10.5051\/jpis.2013.43.5.221"},{"key":"e_1_2_14_33_2","unstructured":"Dentsply Sirona Astra Tech Implant System EV Clinical & Laboratory Manual Screw-Retained Restorations 2017 https:\/\/www.dentsplysirona.com\/content\/dam\/master\/education\/documents\/upload\/A\/ATIS%20EV%20Screw-retained%20manual%20_32671183-US-1705.pdf."},{"key":"e_1_2_14_34_2","unstructured":"DIO Implant Dio Product Catalog 2024 https:\/\/hq.dionavi.com\/images\/catalog\/26_240207_DIO-Product-Catalog-Ver-6.3_FDA_Final_View.pdf."},{"key":"e_1_2_14_35_2","unstructured":"Implance IMPLANCE Dental Implant System 2022 https:\/\/implance.com\/wp-content\/themes\/implancetheme\/docs\/en\/implanceCatalogEN-0822.pdf."},{"key":"e_1_2_14_36_2","doi-asserted-by":"publisher","DOI":"10.3390\/medicina61071187"},{"key":"e_1_2_14_37_2","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10024-1950"}],"container-title":["International Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/ijod\/4941557","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1155\/ijod\/4941557","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/ijod\/4941557","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T08:19:38Z","timestamp":1790410778000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/ijod\/4941557"}},"subtitle":[],"editor":[{"given":"Hannah","family":"Wesley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1155\/ijod\/4941557"],"URL":"https:\/\/doi.org\/10.1155\/ijod\/4941557","archive":["Portico"],"relation":{},"ISSN":["1687-8728","1687-8736"],"issn-type":[{"value":"1687-8728","type":"print"},{"value":"1687-8736","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"2026-05-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-12","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"4941557"}}