{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T12:49:13Z","timestamp":1792586953336,"version":"4.5.0"},"reference-count":43,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T00:00:00Z","timestamp":1792540800000},"content-version":"vor","delay-in-days":293,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Ophthalmology"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate clinical and patient\u2010reported outcomes of the Clareon PanOptix (CP) hydrophobic acrylic trifocal IOL in eyes with previous myopic laser refractive surgery (LRS).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This single\u2010center, ambispective study included 94 eyes of 47 patients with previous myopic LRS undergoing CP implantation. At 6\u2009months, monocular visual acuity (VA), refraction, and refractive outcomes were assessed. Prediction accuracy was compared using Barrett True\u2010K and Haigis\u2010L with conventional keratometry (CK) or total keratometry (TK) on the IOLMaster 700 and Barrett True\u2010K with CK or TK on the Argos; Argos TK incorporated Pentacam\u2010measured posterior corneal astigmatism. Spectacle dependence, satisfaction, and visual disturbances were assessed. Correlations between preoperative corneal higher\u2010order aberrations (HOAs) and postoperative outcomes were analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Mean uncorrected VAs were 0.028\u2009\u00b1\u20090.087 logMAR for distance, 0.177\u2009\u00b1\u20090.130 logMAR for intermediate, and 0.093\u2009\u00b1\u20090.137 logMAR for near. The mean postoperative spherical equivalent was \u22120.142\u2009\u00b1\u20090.375 D, with 81% of eyes within \u00b10.50 D of emmetropia. In a retrospective comparison of IOL power calculation methods, Barrett True\u2010K with TK on the IOLMaster 700 yielded the highest observed proportion of eyes within \u00b10.50 D of the intended target (78.7%). After Holm\u2013Bonferroni correction, preoperative corneal HOA RMS and nonspherical HOA RMS at a 3.0\u2010mm diameter were associated with uncorrected distance VA, whereas corneal HOAs at larger analysis diameters (5.0\u20136.0\u2009mm) were associated with postoperative visual disturbances. Patients reported high satisfaction (3.09\u2009\u00b1\u20090.62) and complete spectacle independence for distance and intermediate vision.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The CP trifocal IOL is an effective option for presbyopia correction in post\u2010myopic LRS eyes meeting predefined preoperative corneal aberration criteria. Refractive predictability depended on device\u2010specific formula\u2013keratometry combinations, with Barrett True\u2010K yielding the highest observed \u00b10.50 D rates with TK (IOLMaster 700) and with CK (Argos). Corneal HOA analysis at specified measurement diameters may further guide patient selection and counseling.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1155\/joph\/7762608","type":"journal-article","created":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T12:33:46Z","timestamp":1792586026000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Hydrophobic Acrylic Trifocal IOL in Post\u2013Laser Refractive Surgery Eyes: Visual Performance, Predictability, and Patient\u2010Reported Outcomes"],"prefix":"10.1155","volume":"2026","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-3293-5665","authenticated-orcid":false,"given":"Yong Hyu","family":"Goh","sequence":"first","affiliation":[{"name":"Department of Ophthalmology Samsung Medical Center Sungkyunkwan University School of Medicine  81 Irwon-ro, Gangnam-gu Seoul 06351 South Korea  skku.edu"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-4551-3323","authenticated-orcid":false,"given":"Yoon Seong","family":"Choi","sequence":"additional","affiliation":[{"name":"The New York University College of Arts and Science  70 Washington Square South New York 10012 New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-8272-5828","authenticated-orcid":false,"given":"Sungho","family":"Choi","sequence":"additional","affiliation":[{"name":"First Samsung Eye Clinic  22, Seocho-daero 78-gil, Seocho-gu Seoul South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Hui","family":"Lim","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology Samsung Medical Center Sungkyunkwan University School of Medicine  81 Irwon-ro, Gangnam-gu Seoul 06351 South Korea  skku.edu"},{"name":"Samsung Advanced Institute for Health Sciences and Technology Sungkyunkwan University  Seoul South Korea  skku.edu"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung Jin","family":"Na","sequence":"additional","affiliation":[{"name":"First Samsung Eye Clinic  22, Seocho-daero 78-gil, Seocho-gu Seoul South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deok Jo","family":"Nam","sequence":"additional","affiliation":[{"name":"First Samsung Eye Clinic  22, Seocho-daero 78-gil, Seocho-gu Seoul South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,21]]},"reference":[{"key":"e_1_2_11_1_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S370061"},{"key":"e_1_2_11_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-018-0908-0"},{"key":"e_1_2_11_3_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-020-01556-0"},{"key":"e_1_2_11_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-018-04218-6"},{"key":"e_1_2_11_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD003169.pub4"},{"key":"e_1_2_11_6_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_1759_22"},{"key":"e_1_2_11_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(00)00795-1"},{"key":"e_1_2_11_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.05.004"},{"key":"e_1_2_11_9_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-0629"},{"key":"e_1_2_11_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(98)00288-8"},{"key":"e_1_2_11_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.12.040"},{"key":"e_1_2_11_12_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-024-03671-8"},{"key":"e_1_2_11_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2021.05.002"},{"key":"e_1_2_11_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.05.017"},{"key":"e_1_2_11_15_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02600-x"},{"key":"e_1_2_11_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001173"},{"key":"e_1_2_11_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20240923-02"},{"key":"e_1_2_11_18_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-67726-8"},{"key":"e_1_2_11_19_2","doi-asserted-by":"publisher","DOI":"10.4103\/IJO.IJO_1844_23"},{"key":"e_1_2_11_20_2","volume-title":"Higher-Order Aberrations and Diffractive Multifocal IoLs","author":"Schallhorn J. M.","year":"2023"},{"key":"e_1_2_11_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2023.e15720"},{"key":"e_1_2_11_22_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-025-04198-2"},{"key":"e_1_2_11_23_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-59487-1"},{"key":"e_1_2_11_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.05.020"},{"key":"e_1_2_11_25_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-018-0110-5"},{"key":"e_1_2_11_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210812-02"},{"key":"e_1_2_11_27_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0223114"},{"key":"e_1_2_11_28_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-61391-7"},{"key":"e_1_2_11_29_2","article-title":"Astigmatism Analysis With a New Swept-Source Optical Coherence Tomography Biometer","author":"Shammas H. J.","year":"2021","journal-title":"ASCRS Annual Meeting"},{"key":"e_1_2_11_30_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20251027-02"},{"key":"e_1_2_11_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-022-05870-9"},{"key":"e_1_2_11_32_2","article-title":"Should You Optimize Your A-Constant? Arguments for and Against A-Constant Optimization","author":"Kretz F. T. A.","year":"2023","journal-title":"Cataract & Refractive Surgery Today Global"},{"key":"e_1_2_11_33_2","volume-title":"The New Ocular Biometers: How do They Stack Up?","author":"Cummings A. B.","year":"2015"},{"key":"e_1_2_11_34_2","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering11020190"},{"key":"e_1_2_11_35_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-025-03992-2"},{"key":"e_1_2_11_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.11.032"},{"key":"e_1_2_11_37_2","doi-asserted-by":"publisher","DOI":"10.3349\/ymj.2007.48.4.627"},{"key":"e_1_2_11_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.aopr.2022.100043"},{"key":"e_1_2_11_39_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000893"},{"key":"e_1_2_11_40_2","doi-asserted-by":"publisher","DOI":"10.1097\/opx.0b013e318263c165"},{"key":"e_1_2_11_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000637"},{"key":"e_1_2_11_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.06.054"},{"key":"e_1_2_11_43_2","first-page":"1396","article-title":"Ocular Aberrations Before and After Myopic Corneal Refractive Surgery: Lasik-Induced Changes Measured With Laser Ray Tracing","volume":"42","author":"Moreno-Barriuso E.","year":"2001","journal-title":"Investigative Ophthalmology & Visual Science"}],"container-title":["Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/joph\/7762608","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1155\/joph\/7762608","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1155\/joph\/7762608","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T12:33:48Z","timestamp":1792586028000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1155\/joph\/7762608"}},"subtitle":[],"editor":[{"given":"Maja","family":"Bohac","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":43,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["10.1155\/joph\/7762608"],"URL":"https:\/\/doi.org\/10.1155\/joph\/7762608","archive":["Portico"],"relation":{},"ISSN":["2090-004X","2090-0058"],"issn-type":[{"value":"2090-004X","type":"print"},{"value":"2090-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"2026-05-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-03","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-21","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"7762608"}}