{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T17:33:08Z","timestamp":1776360788448,"version":"3.51.2"},"reference-count":46,"publisher":"Wiley","license":[{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/100007691","name":"University of Beira Interior","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007691","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Modelling and Simulation in Engineering"],"published-print":{"date-parts":[[2012]]},"abstract":"<jats:p>A comprehensive and detailed computational fluid dynamics (CFDs) modelling of air flow and heat transfer in an open refrigerated display cabinet (ORDC) is performed in this study. The physical-mathematical model considers the flow through the internal ducts, across fans and evaporator, and includes the thermal response of food products. The air humidity effect and thermal radiation heat transfer between surfaces are taken into account. Experimental tests were performed to characterize the phenomena near physical extremities and to validate the numerical predictions of air temperature, relative humidity, and velocity. Numerical and experimental results comparison reveals the predictive capabilities of the computational model for the optimized conception and development of this type of equipments. Numerical predictions are used to propose geometrical and functional parametric studies that improve thermal performance of the ORDC and consequently food safety.<\/jats:p>","DOI":"10.1155\/2012\/973601","type":"journal-article","created":{"date-parts":[[2012,4,22]],"date-time":"2012-04-22T17:02:48Z","timestamp":1335114168000},"page":"1-17","source":"Crossref","is-referenced-by-count":6,"title":["Detailed CFD Modelling of Open Refrigerated Display Cabinets"],"prefix":"10.1155","volume":"2012","author":[{"given":"Pedro Dinis","family":"Gaspar","sequence":"first","affiliation":[{"name":"Electromechanical Engineering Department, University of Beira Interior, Rua Fonte do Lameiro-Edif\u00edcio 1 das Engenharias, 6201-001 Covilh\u00e3, Portugal"}]},{"given":"L. C. Carrilho","family":"Gon\u00e7alves","sequence":"additional","affiliation":[{"name":"Electromechanical Engineering Department, University of Beira Interior, Rua Fonte do Lameiro-Edif\u00edcio 1 das Engenharias, 6201-001 Covilh\u00e3, Portugal"}]},{"given":"R. A.","family":"Pitarma","sequence":"additional","affiliation":[{"name":"Mechanical Engineering Department, Polytechnic Institute of Guarda, High School of Technology and Management, Avenida Dr. Francisco S\u00e1 Carneiro No. 50, 6300-559 Guarda, Portugal"}]}],"member":"311","reference":[{"issue":"11","key":"1","first-page":"46","volume":"41","year":"1999","journal-title":"ASHRAE Journal"},{"key":"3","year":"2011"},{"key":"4","volume-title":"Energy savings potential for commercial refrigeration equipment","year":"1996"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1016\/j.applthermaleng.2010.11.020"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2005.06.007"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2007.09.005"},{"key":"8","year":"2006"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheatfluidflow.2003.11.001"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2004.09.002"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1016\/j.expthermflusci.2004.01.012"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2005.12.011"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2006.02.004"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1016\/j.enbuild.2006.02.003"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-7007(00)00015-3"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1115\/1.1478586"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2004.08.002"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2004.12.009"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijthermalsci.2009.03.003"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1016\/S1359-4311(00)00040-5"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2010.02.028"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfoodeng.2004.08.016"},{"key":"24","doi-asserted-by":"publisher","DOI":"10.1016\/j.applthermaleng.2009.02.016"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2006.10.006"},{"key":"28","year":"2002"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.1007\/BF01061452"},{"key":"33","series-title":"Computational Studies (5)","volume-title":"Evaluation of CFD codes by comparison of numerical predictions of an air-conditioned room case study","year":"2004"},{"key":"34","year":"1980"},{"issue":"2","key":"35","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/0045-7825(74)90029-2","volume":"3","year":"1974","journal-title":"Computer Methods in Applied Mechanics and Engineering"},{"issue":"1","key":"36","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/0021-9991(86)90099-9","volume":"62","year":"1986","journal-title":"Journal of Computational Physics"},{"key":"37","year":"1980"},{"issue":"3","key":"38","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1080\/10407788608913517","volume":"10","year":"1986","journal-title":"Numerical heat transfer"},{"issue":"1","key":"39","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0021-9991(79)90145-1","volume":"32","year":"1979","journal-title":"Journal of Computational Physics"},{"key":"40","year":"1993"},{"key":"44","year":"1997"},{"key":"45","year":"1988"},{"key":"46","year":"1997"},{"key":"49","doi-asserted-by":"publisher","DOI":"10.1155\/2008\/692748"},{"key":"50","year":"1969"},{"issue":"1","key":"51","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1080\/089161599269825","volume":"12","year":"1999","journal-title":"Experimental Heat Transfer"},{"key":"52","year":"1984"},{"key":"53","year":"1994"},{"key":"54","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2005.10.012"},{"key":"55","doi-asserted-by":"publisher","DOI":"10.1016\/S0956-7135(02)00058-0"},{"key":"56","doi-asserted-by":"publisher","DOI":"10.1016\/j.applthermaleng.2008.10.003"},{"key":"57","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrefrig.2011.05.001"},{"key":"58","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-1699(01)00179-X"}],"container-title":["Modelling and Simulation in Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/mse\/2012\/973601.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/mse\/2012\/973601.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/mse\/2012\/973601.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,20]],"date-time":"2017-06-20T13:38:03Z","timestamp":1497965883000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.hindawi.com\/journals\/mse\/2012\/973601\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012]]},"references-count":46,"alternative-id":["973601","973601"],"URL":"https:\/\/doi.org\/10.1155\/2012\/973601","relation":{},"ISSN":["1687-5591","1687-5605"],"issn-type":[{"value":"1687-5591","type":"print"},{"value":"1687-5605","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012]]}}}