{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T16:02:26Z","timestamp":1773763346507,"version":"3.50.1"},"reference-count":32,"publisher":"Wiley","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008530","name":"FEDER","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Ophthalmology"],"published-print":{"date-parts":[[2018]]},"abstract":"<jats:p><jats:italic>Purpose.<\/jats:italic> To compare the through-focus visual performance in a clinical population of pseudophakic patients implanted with two new trifocal intraocular lenses (IOLs) and one extended depth of focus IOL. <jats:italic>Methods.<\/jats:italic> Prospective, nonrandomized, examiner-masked case series. Twenty-three patients received the FineVision\u00ae and seven patients received the PanOptix\u2122 trifocal IOLs. Fifteen patients received the Symfony extended depth of focus IOL. Mean age of patients was 63\u2009\u00b1\u20098 years. Through-focus visual acuity was measured from \u20133.00 to +1.00\u2009D vergences. Contrast sensitivity was measured with and without a source of glare. Light disturbances were evaluated with the Light Distortion Analyzer. <jats:italic>Results.<\/jats:italic> Though-focus evaluation showed that trifocal IOLs performed significantly better at near distance (33 and 40\u2009cm), and extended depth of focus performed significantly better at intermediate distance (1.0\u2009m). Contrast sensitivity function with glare and dysphotopsia was similar between the three IOLs and subjective response to questionnaire showed a significantly higher score (worse performance) for the extended depth of focus IOL compared to both trifocal IOLs in the bothersome subscale (<mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"M1\"><mml:mi>p<\/mml:mi><mml:mo>&lt;<\/mml:mo><mml:mn>0.05<\/mml:mn><\/mml:math>). <jats:italic>Conclusions<\/jats:italic>. Trifocal IOLs grant better performance at near distance while extended depth of focus IOL performs better at intermediate distance. Objective dysphotopsia measured with the Light Distortion Analyzer is not reduced in extended depth of focus IOL compared to trifocal IOLs.<\/jats:p>","DOI":"10.1155\/2018\/6165493","type":"journal-article","created":{"date-parts":[[2018,1,31]],"date-time":"2018-01-31T23:35:17Z","timestamp":1517441717000},"page":"1-8","source":"Crossref","is-referenced-by-count":93,"title":["Through-Focus Vision Performance and Light Disturbances of 3 New Intraocular Lenses for Presbyopia Correction"],"prefix":"10.1155","volume":"2018","author":[{"given":"Santiago","family":"Escand\u00f3n-Garc\u00eda","sequence":"first","affiliation":[{"name":"Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal"}]},{"given":"Filomena J.","family":"Ribeiro","sequence":"additional","affiliation":[{"name":"Hospital da Luz, Lisboa, Portugal"}]},{"given":"Colm","family":"McAlinden","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Glangwili Hospital, Hywel Dda University Hospital Board, Carmarthen, UK"},{"name":"School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1045-4455","authenticated-orcid":true,"given":"Ant\u00f3nio","family":"Queir\u00f3s","sequence":"additional","affiliation":[{"name":"Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9050-4170","authenticated-orcid":true,"given":"Jos\u00e9 M.","family":"Gonz\u00e1lez-M\u00e9ijome","sequence":"additional","affiliation":[{"name":"Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal"}]}],"member":"311","reference":[{"key":"1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.12.002"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.85.7.816"},{"key":"3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.04.010"},{"key":"4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.11.032"},{"key":"5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.05.041"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000001"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.06.034"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150423-04"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S103375"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-5341"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.10.061"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01816-3"},{"key":"13","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20130819-03"},{"key":"14","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-011-1696-7"},{"key":"15","doi-asserted-by":"publisher","DOI":"10.1080\/09500340.2013.842614"},{"key":"16","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.20.7.075002"},{"key":"17","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/278425"},{"key":"18","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.21.7.075003"},{"key":"19","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-015-3240-7"},{"key":"20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.07.033"},{"key":"21","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0046780"},{"key":"22","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182993856"},{"key":"23","doi-asserted-by":"publisher","DOI":"10.1001\/archophthalmol.2012.1603"},{"key":"24","first-page":"127","volume":"3","year":"2015","journal-title":"Journal of Emmetropia"},{"key":"25","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170621-08"},{"key":"26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2017.04.013"},{"key":"27","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160121-07"},{"key":"28","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.11.012"},{"key":"29","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.7.001877"},{"key":"30","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.10-67951"},{"key":"31","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-9969"},{"key":"32","doi-asserted-by":"publisher","DOI":"10.1080\/02713683.2017.1379541"}],"container-title":["Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/downloads.hindawi.com\/journals\/joph\/2018\/6165493.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/joph\/2018\/6165493.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/downloads.hindawi.com\/journals\/joph\/2018\/6165493.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,18]],"date-time":"2020-05-18T23:14:38Z","timestamp":1589843678000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.hindawi.com\/journals\/joph\/2018\/6165493\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":32,"alternative-id":["6165493","6165493"],"URL":"https:\/\/doi.org\/10.1155\/2018\/6165493","relation":{},"ISSN":["2090-004X","2090-0058"],"issn-type":[{"value":"2090-004X","type":"print"},{"value":"2090-0058","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018]]}}}