{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T01:10:09Z","timestamp":1773796209295,"version":"3.50.1"},"reference-count":11,"publisher":"S. Karger AG","issue":"4","license":[{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.karger.com\/Services\/SiteLicenses"},{"start":{"date-parts":[[2010,1,1]],"date-time":"2010-01-01T00:00:00Z","timestamp":1262304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.karger.com\/Services\/SiteLicenses"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Stereotact Funct Neurosurg"],"published-print":{"date-parts":[[2010]]},"abstract":"<jats:p>&lt;i&gt;Background\/Aims:&lt;\/i&gt; In Gamma Knife radiosurgery, T&lt;sub&gt;1&lt;\/sub&gt; MRI is most commonly used and is generally sufficient for targeting the trigeminal nerve. For patients whose trigeminal nerves are unclear on T&lt;sub&gt;1&lt;\/sub&gt; MRI, FIESTA MRI supplements anatomical structure visualization and may improve trigeminal nerve delineation. The purpose of this study was to develop a registration strategy for T&lt;sub&gt;1&lt;\/sub&gt; and FIESTA MRIs. &lt;i&gt;Methods:&lt;\/i&gt; We conducted a retrospective study on 54 trigeminal neuralgia patients. All patients were scanned with T&lt;sub&gt;1&lt;\/sub&gt; and FIESTA MRIs. We evaluated 4 methods of registration: automatic image definition, superior-slice definition, middle-slice definition and inferior-slice definition. Target discrepancies were measured by deviations from an intracranial landmark on T&lt;sub&gt;1&lt;\/sub&gt; and FIESTA MR images. &lt;i&gt;Results:&lt;\/i&gt; The overall range in registration error was 0.10\u20135.19 mm using superior-, 0.10\u20131.56 mm using middle- and 0.14\u20132.89 mm using inferior-slice definition. Registration error &gt;2 mm was observed in 11% of the patients using superior-, 4% using middle- and 7% using inferior-slice FIESTA MRI definition. &lt;i&gt;Conclusions:&lt;\/i&gt; Among patients for whom FIESTA and T&lt;sub&gt;1&lt;\/sub&gt; MRI are used, registration based on middle-slice definition reduces registration error and improves targeting of the trigeminal nerve.<\/jats:p>","DOI":"10.1159\/000315461","type":"journal-article","created":{"date-parts":[[2010,6,8]],"date-time":"2010-06-08T08:33:50Z","timestamp":1275986030000},"page":"239-245","source":"Crossref","is-referenced-by-count":7,"title":["Image Registration Strategy of T&lt;sub&gt;1&lt;\/sub&gt;-Weighted and FIESTA MRI Sequences in Trigeminal Neuralgia Gamma Knife Radiosurgery"],"prefix":"10.1159","volume":"88","author":[{"given":"Tony J.C.","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald","family":"Brisman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zheng Feng","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiang","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven R.","family":"Isaacson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinesh N.","family":"Shah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emi J.","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tian","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"127","published-online":{"date-parts":[[2010,6,8]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1159%2F000056421"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1159%2F000056422"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016%2Fj.ijrobp.2004.04.020"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1148%2Fradiol.2282020439"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007%2Fs003300000452"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1227%2F01.NEU.0000154709.44776.50"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3340%2Fjkns.2008.44.4.199"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1118%2F1.1944287"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097%2F00004728-199403000-00005"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097%2F00006123-199601000-00038"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109%2FTMI.2002.1009381"}],"container-title":["Stereotactic and Functional Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/315461","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.karger.com\/Article\/Pdf\/315461","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T19:30:43Z","timestamp":1745436643000},"score":1,"resource":{"primary":{"URL":"https:\/\/karger.com\/article\/doi\/10.1159\/000315461"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010]]},"references-count":11,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2010,7,1]]}},"URL":"https:\/\/doi.org\/10.1159\/000315461","archive":["Portico"],"relation":{},"ISSN":["1011-6125","1423-0372"],"issn-type":[{"value":"1011-6125","type":"print"},{"value":"1423-0372","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010]]}}}